Magnetotermico 4p 10A 6kA curva C pLS6-C10 / 4
PLS6, 6kA, 4P, curva C, 10A
Eaton Moeller series xPole - PLS6/M MCB. PLS6, 4 pole, tripping characteristic: C, rated current In: 10 A, rated switching capacity IEC/EN 60898-1: 6 kA
Disjuntor miniatura (MCB), PLS6, 4 polos, característica de disparo: C, corrente nominal In: 10 A, capacidade nominal de comutação de acordo com IEC/EN 60898-1: 6 kA, Comutadores para aplicações residenciais e comerciais
Disjuntores, fusíveis > Interruptor magnetotérmico
Switchgear modular - grande residencial
Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER
| Product Name | Eaton Moeller series xPole - PLS6/M MCB |
| Catalog Number | 243083 |
| EAN | 4015082430832 |
| Product Length/Depth | 85 mm |
| Product Height | 73 mm |
| Product Width | 70 mm |
| Product Weight | 0.48 kg |
| Compliances | RoHS conform |
| Model Code | PLS6-C10/4-MW |
| Used with | PLS6 Miniature circuit breaker |
| Amperage Rating | 10 A |
| Features | Concurrently switching N-neutral Additional equipment possible |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Pollution degree | 2 |
| Degree of protection | IP20 |
| Equipment heat dissipation, current-dependent | 6 W |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Tripping characteristic | C |
| Ambient operating temperature - max | 75 °C |
| Ambient operating temperature - min | -25 °C |
| Built-in depth | 70.5 mm |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Current limiting class | 3 |
| Frequency rating - max | 60 Hz |
| Frequency rating - min | 50 Hz |
| Heat dissipation capacity | 0 W |
| Heat dissipation per pole, current-dependent | 0 W |
| Width in number of modular spacings | 4 |
| Voltage type | AC |
| Overvoltage category | III |
| Number of poles | Four-pole |
| Release characteristic | C |
| Type |
|
| Special features | Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity |
| Application |
|
| Number of poles (protected) | 4 |
| Number of poles (total) | 4 |
| Rated insulation voltage (Ui) | 440 V |
| Rated operational current for specified heat dissipation (In) | 10 A |
| Rated operational voltage (Ue) - max | 400 V |
| Rated short-circuit breaking capacity (IEC/EN 60898-1) - Icn at 230 V | 6 kA |
| Rated short-circuit breaking capacity (IEC/EN 60898-1)- Icn at 400 V | 6 kA |
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V | 0 kA |
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 400 V | 0 kA |
| Rated switching capacity (IEC/EN 60898-1) | 6 kA |
| Static heat dissipation, non-current-dependent | 0 W |
| Power loss | 4.7 W |
| Característica | Valor |
|---|---|
| Built-in depth (EF000218) | 70.5 mm |
| Release characteristic (EF000889) | C |
| Number of poles (total) (EF008618) | 4 |
| Number of protected poles (EF005548) | 4 |
| Rated current (EF000227) | 10 A |
| Rated voltage (EF000228) | 400 V |
| Rated insulation voltage Ui (EF001366) | 440 V |
| Rated impulse withstand voltage Uimp (EF011980) | 4 kV |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) | 6 kA |
| Voltage type (EF000187) | AC |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) | 6 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) | 0 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) | 0 kA |
| Frequency (EF000416) | 50 Hz |
| Power loss (EF005387) | 4.7 W |
| Current limiting class (EF002568) | 3 |
| Flush-mounted installation (EF007517) | false |
| Concurrently switching neutral conductor (EF005997) | true |
| Over voltage category (EF002569) | 3 |
| Pollution degree (EF002570) | 2 |
| Additional equipment possible (EF008148) | true |
| Width in number of modular spacings (EF002950) | 4 |
| Degree of protection (IP) (EF005474) | IP20 |
| Ambient temperature during operating (EF007515) | -25 °C |
| Connectable conductor cross section multi-wired (EF007343) | 1 mm² |
| Connectable conductor cross section solid-core (EF007337) | 1 mm² |
| Explosion-proof (EF004663) | false |
| Título: | Tamanho: | Tipo: |
|---|---|---|
| PDF EATON XEFFECT SWITCHGEAR RANGE EN.pdf | 8 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| PLS6-C10/4-MW Y7-243083 243083 PT_243083.pdf | 95 Kbytes |
![]() |
Não há comentários do produto ainda.
| Avaliação: |
|
| Nome: | |
| Email: | |
| Título: | |
| Opinión: | |
| Você recomendaria esse produto para comprar? | |
|
|
|
| Adicionar avaliação | |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.