EMR6-IF1-A-1

184782

Y7-184782

EATON-MOELLER

Atual relés de monitoramento, de 3 de 30 mA, 10 - 100 mA, de 0,1 - 1 A, 24 - 240 V CA, 50/60 Hz, 24 - 240 V DC

Relé de Monitorização Janela Intensidade; 0.3-1.5-A, 3-15A; 24-240V AC/DC

Eaton Moeller® series EMR6 Window-current monitoring relay, Current measuring range: 3 - 30 mA, 10 - 100 mA, 0.1 - 1 A, Supply voltage: 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC

Mais detalhes


Relés de temporização (KETR, KEMR, KESR)

* Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER

Preço total: $257.52
Preço unitário: $257.52

Quantidade Preço
1+$257.52
2+$244.79
*Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Best sellers

Mais informação



General specifications

Product Name
Eaton Moeller® series EMR6 Window-current monitoring relay
Catalog Number
184782
EAN
4015081788187
Product Length/Depth
103.7 mm
Product Height
85.6 mm
Product Width
22.5 mm
Product Weight
0.15 kg
Certifications
EAC
CSA-C22.2 No. 14
RMRS
CCC
GL
UL 508
RCM
Catalog Notes
Extension of the measurement range possible with current transformers
Model Code
EMR6-IF1-A-1

Especificações do produto

Type
Current monitoring relay
Air discharge
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
Electric connection type
Screw connection
Pollution degree
3
Power consumption
2.6 VA
Burst impulse
According to IEC/EN 61000-4-4, level 3
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Rated impulse withstand voltage (Uimp)
4000 V AC
Rated operational current (Ie)
4 A at AC-12, 230 V
4 A at DC-12, 24 V
Lifespan, electrical
100,000 Operation (at 230 V, AC-12, 4 A)
Screwdriver size
4 x 0.8 mm, Terminal screw
Voltage type
AC/DC
Connection type
Snap fixing, top-hat rail IEC/EN 60715
Mounting position
As required
Shock resistance
Class 2
Overvoltage category
III
Short-circuit protection rating
Max. 10 A Fast/gL, Fuse, Relay output contacts
Duty factor
100 %, Power supply
Degree of protection
Enclosure: IP50
Terminals: IP20
Supply voltage
24 - 240 V AC, 50/60 Hz
24 - 240 V DC
Hysteresis function
Single-phase hysteresis possible
DC-current hysteresis
Delay time
Adjustable from 0.1 - 30 s, Response delay time
Switch-on delay: none = 0 or adjustable from 0.1 to 30 s
On-delay
0.1 - 30 ms
Surge rating
According to IEC/EN 61000-4-5 Level 4
Electromagnetic compatibility
According to IEC/EN 60947-6-2
Temperature error
0.06 %/°C, Measuring circuits
Terminal capacity (flexible with ferrule AWG)
2 x 18-16
Terminal capacity (flexible with ferrule)
2 x 0.5-1.5 mm²
Terminal capacity (solid AWG)
18 - 14
Functions
Single-phase under current possible
Single-phase over current possible
Monitoring of single-phase DC and AC networks
DC-voltage under current
DC-voltage over current
Terminal capacity (solid)
1 x 0.5-2.5 mm²
Hysteresis
5 %
Immunity to line-conducted interference
Level 3 (according to IEC/EN 61000-4-6)
Tightening torque
0.8 Nm, Screw terminals
Min. 0.6 Nm, Screw terminals
Immunity to radiation
Level 3 (according to IEC/EN 61000-4-3)
Voltage tolerance
1.1 x Uc
0.85 x Uc
Timing cycle
0.5 %, Time error within supply voltage
0.06 %/°C, Time error within temperature range
30 s, Reset delay/Off-delay time
0.5 % Error within supply voltage (Measuring circuits)
LED indicator
Status indication of Supply voltage: Green LED
Status indication of measured value: Red LED
Status indication of energized output relay: Yellow LED
Status indication of Supply voltage: Green, solid light
Other states depending on fault (see IL): Measured value
Lifespan, mechanical
30,000,000 Operations
Monitoring function
Overcurrent and undercurrent (window)
Overcurrent
Undercurrent
Adjustable delay-on energization time - min
0.1 s
Adjustable off-delay time - min
0.1 s
Ambient operating temperature - max
60 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - max
85 °C
Ambient storage temperature - min
40 °C
Current measurement - max
1 A
Current measurement - min
0.01 A
Measuring cycle
80 ms
Number of contacts (change-over contacts)
2
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
0
Permitted delay-on energization time - max
30 s
Permitted off-delay time - max
30 s
Rated control supply voltage (Us) at AC, 50 Hz - max
240 V
Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
Rated control supply voltage (Us) at AC, 60 Hz - max
240 V
Input current
Input B3-C: 0.1 - 1 A
Input B1-C: 0.003 - 0.03 A
Input B2-C: 0.01 - 0.1 A
Rated control supply voltage (Us) at AC, 60 Hz - min
24 V
Rated control supply voltage (Us) at DC - max
240 V
Rated control supply voltage (Us) at DC - min
24 V
Rated frequency - max
60 Hz
Rated frequency - min
50 Hz
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
3 A
Rated operational current (Ie) at DC-13, 24 V
2 A
Rated operational voltage (Ue) at AC - max
250 V
Product category
EMR Measuring and monitoring relays
Type of current
AC/DC
Voltage measurement - min
24 V
Voltage measurement - max
240 V
Voltage type of supply voltage
AC/DC
Voltage type of operating voltage
AC/DC
Rated switch current
4 A
Supply voltage at AC, 50 Hz - min
24 V
Supply voltage at AC, 50 Hz - max
240 V
Supply voltage at AC, 60 Hz - min
24 V
Supply voltage at AC, 60 Hz - max
240 V
Supply voltage at DC - min
24 V
Supply voltage at DC - max
240 V
Response value amperage 1 - min
0.1 A
Response value amperage 1 - max
1 A
Response value amperage 2 - min
0.003 A
Response value amperage 2 - max
0.03 A
Operating voltage at AC, 50 Hz - min
24 V
Operating voltage at AC, 50 Hz - max
240 V
Operating voltage at AC, 60 Hz - min
24 V
Operating voltage at AC, 60 Hz - max
240 V
Operating voltage at DC - min
24 V
Operating voltage at DC - max
240 V

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.