Air discharge
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
Burst impulse
According to IEC/EN 61000-4-4, level 3
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Rated impulse withstand voltage (Uimp)
Rated operational current (Ie)
4 A at AC-12, 230 V
4 A at DC-12, 24 V
Lifespan, electrical
100,000 Operation (at 230 V, AC-12, 4 A)
Screwdriver size
4 x 0.8 mm, Terminal screw
Connection type
Snap fixing, top-hat rail IEC/EN 60715
Short-circuit protection rating
Max. 10 A Fast/gL, Fuse, Relay output contacts
Degree of protection
Enclosure: IP50
Terminals: IP20
Delay time
On delay: None = 0 or adjustable from 0.1 to 30 s
Surge rating
According to IEC/EN 61000-4-5 Level 4
Electromagnetic compatibility
According to IEC/EN 60947-6-2
Temperature error
0.06 %/°C, Measuring circuits
Terminal capacity (flexible with ferrule AWG)
Terminal capacity (flexible with ferrule)
Terminal capacity (solid AWG)
Functions
Single-phase over current possible
DC-voltage under current
Monitoring of single-phase DC and AC networks
Single-phase under current possible
DC-voltage over current
Terminal capacity (solid)
Immunity to line-conducted interference
Level 3 (according to IEC/EN 61000-4-6)
Tightening torque
Min. 0.6 Nm, Screw terminals
0.8 Nm, Screw terminals
Immunity to radiation
Level 3 (according to IEC/EN 61000-4-3)
Timing cycle
0.06 %/°C, Time error within temperature range
0.5 % Error within supply voltage (Measuring circuits)
0.5 %, Time error within supply voltage
Adjustable from 0.1 – 30 s, Reset delay/Off-delay time
LED indicator
Status indication of Undercurrent: Red, flashing light
Status indication of Output relay excited: Yellow, solid light
Status indication of energized output relay: Yellow LED
Status indication of Supply voltage: Green, solid light
Status indication of active release delay: Green, flashing light
Status indication of Supply voltage: Green LED
Status indication of measured value: Red LED
Adjustable delay-on energization time - min
Adjustable off-delay time - min
Ambient operating temperature - max
Ambient operating temperature - min
Ambient storage temperature - max
Ambient storage temperature - min
Current measurement - max
Current measurement - min
Number of contacts (change-over contacts)
Number of contacts (normally closed contacts)
Number of contacts (normally open contacts)
Permitted delay-on energization time - max
Permitted off-delay time - max
Rated control supply voltage (Us) at AC, 50 Hz - max
Rated control supply voltage (Us) at AC, 50 Hz - min
Rated control supply voltage (Us) at AC, 60 Hz - max
Input current
Input B1-C: 0.3 - 1.5 A
Input B3-C: 3 - 15 A
Input B2-C: 1 - 5 A
Rated control supply voltage (Us) at AC, 60 Hz - min
Rated control supply voltage (Us) at DC - max
Rated control supply voltage (Us) at DC - min
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
Rated operational current (Ie) at DC-13, 24 V
Rated operational voltage (Ue) at AC - max
Product category
EMR Measuring and monitoring relays
Voltage measurement - min
Voltage measurement - max
Voltage type of supply voltage
Voltage type of operating voltage
Supply voltage at AC, 50 Hz - min
Supply voltage at AC, 50 Hz - max
Supply voltage at AC, 60 Hz - min
Supply voltage at AC, 60 Hz - max
Response value amperage 1 - min
Response value amperage 1 - max
Response value amperage 2 - min
Response value amperage 2 - max
Operating voltage at AC, 50 Hz - min
Operating voltage at AC, 50 Hz - max
Operating voltage at AC, 60 Hz - min
Operating voltage at AC, 60 Hz - max