ANUNCIAR
CL-PKZ0 082881 Y7-82881 EATON ELECTRIC Limitador de intensidad 3 polos 63 A 400 V AC/100 Ka 690 V AC/10 kA Ver más grande
Las imágenes son sólo a título ilustrativo. Por favor, revise la ficha técnica.

CL-PKZ0 082881 Y7-82881 EATON ELECTRIC Limitador de intensidad 3 polos 63 A 400 V AC/100 Ka 690 V AC/10 kA

CL-PKZ0

082881

Y7-82881

EATON-MOELLER

Limitador de intensidad, 3 polos, 63 A, 400 V AC/100 Ka, 690 V AC/10 kA

Eaton Moeller® series PKZ0 Current limiter, 3p, 63A, 400VAC/100kA, 690VAC/10kA

Limitador de corriente de 3 polos, submontable con disyuntor de tamaño PKZM0, PKZM4, PKZM01, Ue = 690 V, Iu = 63 A

Más detalles


Componentes industriales de baja tensión > Limitador de corriente

Interruptores Protectores de Motor

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $45.18
Precio unitario: $45.18
Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

productos relacionados

Comprados juntos habitualmente

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton Moeller® series PKZ0 Current limiter
Catalog Number
082881
EAN
4015080828815
Product Length/Depth
56 mm
Product Height
90 mm
Product Width
45 mm
Product Weight
0.201 kg
Certifications
CSA Class No.: 3211-05
UL 508
CSA-C22.2 No. 14
IEC/EN 60947-4-1
CE
UL Category Control No.: NLRV
CSA
CSA File No.: 165628
UL
UL File No.: E36332
Model Code
CL-PKZ0

Características y Funciones

Functions
Short-circuit current limiter
Can be used for individual and group protection

General

Mounting Method
DIN rail
Mounting position
Next to or behind the motor protective circuit breaker
Overvoltage category
III
Pollution degree
3
Product category
Accessories
Rated impulse withstand voltage (Uimp)
6000 V AC
Type
Motor-protective circuit-breaker, non-auto-protected in order to increase switching capacity

Condiciones climáticas ambientales

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C

Especificaciones eléctricas

Rated uninterrupted current (Iu)
63 A

Clasificación de cortocircuito

Rated conditional short-circuit current (Iq)
0 kA

Verificación del diseño

Equipment heat dissipation, current-dependent Pvid
8.4 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
2.8 W
Rated operational current for specified heat dissipation (In)
63 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 082881 Interruptores de baja tensión (EC000239)
Característica Valor
Potencia aparente máx. (EF008258) 0 VA
Método de montaje (EF000003) Carril DIN
Corriente nominal de cortocircuito condicional Iq (EF001444) 0 kA
Intensidad nominal permanente Iu (EF001389) 63 A
Limitadores de corriente (EF007333)

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.