Convertidor de Frecuencia, Ent: 3 x 230 V, Sal: 3 x 230 V, 60 A, 15kW,

Eaton DA1 Frequency inverter, 230 V AC, 3-phase, 61 A, 15 kW, IP20/NEMA 0, Radio interference suppression filter, Additional PCB protection, DC link choke, FS5

Variador de frecuencia, Referencia de grupo de piezas (p. ej., DIL): DA1, Tensión nominal de funcionamiento: Ue = 230 V CA, 3 fases, 240 V CA, 3 fases, Tensión de salida con Ve: U2 = 230 V CA, 3 fases, 240 V CA, 3 fases, Tensión de red (50/60 Hz): ULN = 200 (-10%) - 240 (+10%) V, Corriente nominal de funcionamiento Con una sobrecarga del 150%: Ie = 61 A, Nota: Corriente nominal de funcionamiento a una frecuencia de conmutación de 8 kHz y una temperatura del aire ambiente de +50 °C, Nota: Ciclo de sobrecarga de 60 s cada 600 s, Potencia nominal del motor asignada Nota: para motores asíncronos trifásicos de 4 polos, con ventilación interna y externa normal con 1500 rpm-1 a 50 Hz o 1800 min-1 a 60 Hz, Ciclo de sobrecarga de 60 s cada 600 s, a 230 V, 50 Hz, Potencia nominal asignada del motor 150 % Sobrecarga: P = 15 kW, 150 % Sobrecarga: IM = 61 A, Potencia nominal del motor asignada Nota: a 220 - 240 V, 60 Hz, Potencia nominal asignada del motor 150 % Sobrecarga: P = 20 CV, Potencia nominal asignada del motor 150 % Sobrecarga: IM = 54 A, Grado de protección: IP20/NEMA 0, Interfaz/bus de campo (incorporado): OP-Bus (RS485)/Modbus RTU, CANopen®, Conexión de bus de campo (opcional): Ethernet IP, DeviceNet, PROFIBUS, PROFINET, Modbus-TCP, EtherCAT, SmartWire-DT, Equipado con: Filtro de supresión de interferencias de radio, Chopper de freno, Protección adicional de PCB, Pantalla OLED, Estrangulador de enlace de CC, Tamaño de fotograma: FS5 , Normas: Requisitos generales: IEC/EN 61800-2, Requisitos EMV: EEC/EN 61800-3, Requisitos de seguridad: IEC/EN 61800-5-1

Más detalles


Componentes industriales de baja tensión > Convertidor de frecuencia de menos de 1 kV

Convertidores de Frecuencia Power XL

Producto nuevo en su embalaje original con todas las garantías y certificaciones de EATON-MOELLER

Precio total: $3,007.80
Precio unitario: $3,007.80
Este precio es por unidad y muestra el valor neto (no incluye impuestos indirectos si son aplicables).

Si nuestro precio no es el mejor solicítenos presupuesto Solicitar presupuesto

productos relacionados

Más vendidos

Más Información



Especificaciones generales

Product Name
Eaton DA1 Variable frequency drive
Catalog Number
197490
EAN
4015081940653
Product Length/Depth
261 mm
Product Height
485 mm
Product Width
234 mm
Product Weight
18.2 kg
Certifications
UL 508C
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-3
IEC/EN 61800-3
Certified by UL for use in Canada
Safety: EN 61800-5-1: 2003
UL
UL report applies to both US and Canada
CUL
CE
IEC/EN61800-5
EAC
RCM
UkrSEPRO
UL File No.: E172143
IEC/EN 61800-2
RoHS, ISO 9001
Catalog Notes
The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request.
Model Code
DA1-32060FB-B20C

General

Cable length
100 m, screened, maximum permissible cable length
C2 ≤ 5 m, maximum motor cable length
200 m, screened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
200 m, unscreened, with motor choke, maximum permissible cable length
C3 ≤ 25 m, maximum motor cable length
Communication interface
PROFIBUS, optional
SmartWire-DT, optional
CANopen®
Modbus-TCP, optional
PROFINET, optional
EtherCAT, optional
DeviceNet, optional
Ethernet IP, optional
OP-Bus (RS485)
Modbus RTU
Connection to SmartWire-DT
Yes
In conjunction with DX-NET-SWD1 SmartWire DT module
Degree of protection
IP20
NEMA Other
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Fitted with:
Control unit
Additional PCB protection
Brake chopper
Internal DC link
Radio interference suppression filter
Breaking resistance
OLED display
PC connection
IGBT inverter
DC link choke
Frame size
FS5
Functions
4-quadrant operation possible
Mounting position
Vertical
Product Category
Variable frequency drives
Protection
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
Protocol
Other bus systems
EtherNet/IP
PROFIBUS
MODBUS
PROFINET IO
TCP/IP
DeviceNet
CAN
Safety function/level
STO (Safe Torque Off, SIL2, PLc Cat 2)
Suitable for
Branch circuits, (UL/CSA)
Radio interference class
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.

Climatic environmental conditions

Ambient operating temperature - min
-10 °C
Altitude
Max. 1000 m
Max. 4000 m
Above 1000 m with 1 % derating per 100 m
Ambient operating temperature - max
50 °C
Ambient operating temperature at 150% overload - min
-10 °C
Ambient operating temperature at 150% overload - max
50 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
60 °C
Climatic proofing
< 95 average relative humidity (RH), no condensation, no corrosion

Main circuit

Efficiency
96.1 % (η)
Heat dissipation at current/speed
190 W at 25% current and 0% speed
240 W at 25% current and 50% speed
260 W at 50% current and 0% speed
330 W at 50% current and 50% speed
390 W at 50% current and 90% speed
480 W at 100% current and 0% speed
590 W at 100% current and 50% speed
720 W at 100% current and 90% speed
Input current ILN at 150% overload
70.2 A
Leakage current at ground IPE - max
0.28 mA
Mains switch-on frequency
Maximum of one time every 30 seconds
Mains voltage - min
200 V
Mains voltage - max
240 V
Operating mode
U/f control
Optional: Vector control with feedback (CLV)
Sensorless vector control (SLV)
Speed control with slip compensation
Output frequency - min
0 Hz
Output frequency - max
500 Hz
Output voltage (U2)
230 V AC, 3-phase
240 V AC, 3-phase
Overload current IL at 150% overload
91.5 A
Rated control supply voltage
10 V DC (Us, max. 10 mA)
Rated frequency - min
48 Hz
Rated frequency - max
62 Hz
Rated operational current (Ie) at 150% overload
61 A
Rated operational power at 220/230 V, 50 Hz, 1-phase
15 kW
Rated operational voltage
240 V AC, 3-phase
230 V AC, 3-phase
Resolution
0.1 Hz (Frequency resolution, setpoint value)
Short-circuit protection rating
90 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
Starting current - max
200 %, IH, max. starting current (High Overload), for 4 seconds every 40 seconds, Power section
Supply frequency
50/60 Hz
Switching frequency
8 kHz, 4 - 24 kHz adjustable (audible), fPWM, Power section, Main circuit
System configuration type
AC supply systems with earthed center point
Voltage rating - max
240 VAC

Motor rating

Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload
54 A
Assigned motor current IM at 230 V, 50 Hz, 150% overload
61 A
Assigned motor power at 230/240 V, 60 Hz, 1-phase
20 HP

Apparent power

Apparent power at 230 V
24.3 kVA
Apparent power at 240 V
25.36 kVA

Braking function

Braking resistance
12 Ω
Braking torque
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Adjustable to 100 % (DC)
Switch-on threshold for the braking transistor
390 VDC

Control circuit

Number of inputs (analog)
2
Number of inputs (digital)
5
Number of outputs (analog)
2
Number of outputs (digital)
2
Number of relay outputs
2 (parameterizable, 1 N/O and 1 changeover contact, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
Rated control voltage (Uc)
24 V DC (external, max. 100 mA)

Design verification

10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 197490 Interruptores de baja tensión (EC001857)
Característica Valor
Tensión de red (EF006780) 200 V
Frecuencia de la red (EF006783) 50/60 Hz
Número de fases de entrada (EF007117) 3
Número de salidas de fase (EF006998) 3
Frecuencia máxima de salida (EF007350) 500 Hz
Tensión de salida máx. (EF009560) 250 V
Corriente de salida nominal I2N (EF009561) 60 A
Potencia cuadrática máxima entregada. Carga a la tensión nominal de entrada (EF007366) 15 kW
Potencia de salida máxima en carga lineal a tensión de salida nominal (EF007364) 15 kW
Consumo de energía (EF000346) 345 W
Tolerancia de frecuencia de potencia simétrica relativa (EF007454) 10 %
Tolerancia de tensión de red simétrica relativa (EF007453) 10 %
Número de salidas analógicas (EF001995) 2
Número de entradas analógicas (EF001994) 2
Número de salidas digitales (EF001993) 2
Número de entradas digitales (EF001992) 5
Con unidad de control (EF001538)
Uso en el sector industrial permitido (EF007294)
Uso permitido en zonas residenciales y comerciales (EF007295)
Soporta el protocolo TCP/IP (EF003050)
Soporta el protocolo PROFIBUS (EF003052)
Soporta el protocolo CAN (EF003053)
Soporta el protocolo INTERBUS (EF003054) No
Soporta el protocolo ASI (EF003051) No
Soporta protocolo KNX (EF003055) No
Soporta el protocolo Modbus (EF003057)
Soporta el protocolo de autopista de datos (EF003058) No
Soporta el protocolo DeviceNet (EF003059)
Soporta el protocolo SUCONET (EF003060) No
Soporta el protocolo LON (EF003017) No
Soporta el protocolo PROFINET IO (EF007525)
Soporta el protocolo PROFINET CBA (EF007524) No
Soporta el protocolo SERCOS (EF006657) No
Soporta el protocolo Foundation Fieldbus (EF007522) No
Soporta el protocolo Ethernet/IP (EF007521)
Soporta el protocolo AS-Interface Safety at Work (EF007519) No
Soporta el protocolo DeviceNet Safety (EF007520) No
Soporta el protocolo de seguridad INTERBUS (EF006662) No
Soporta el protocolo PROFIsafe (EF007526) No
Soporta el protocolo SafetyBUS p (EF007527) No
Soporta protocolo para BACnet (EF011944) No
Soporta el protocolo para otros sistemas bus (EF003062)
Número de interfaces HW Ethernet industrial (EF003020) 0
Número de interfaces PROFINET (EF006932) 0
Número de interfaces HW RS232 (EF003021) 0
Número de interfaces HW RS422 (EF003022) 0
Número de interfaces HW RS485 (EF003023) 1
Número de interfaces HW en serie TTY (EF003024) 0
Número de interfaces HW USB (EF003025) 0
Número de interfaces HW en paralelo (EF003026) 0
Número de interfaces HW Otras (EF003027) 0
Con interfaz óptica (EF003028) No
Con conexión a PC (EF006107)
Resistencia de frenado integrada (EF007293)
Operación de 4 cuadrantes posible (EF006803)
Tipo de convertidor (EF006978) Convertidor U
Grado de protección (IP) (EF005474) IP20
Grado de protección (NEMA) (EF011959) Otros
Altura (EF000040) 485 mm
Anchura (EF000008) 234 mm
Profundidad (EF000049) 261 mm

Datasheet - PDF

Opiniones: (0)

Ningún comentario por el momento.

Añadir comentario
ocultar
Valoración:
Nombre:
Email:
Título:
Opinión:
  Captcha
  Añadir comentario

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.