ANUNCIAR
7KM1020-0BA01-1DA0 SIEMENS SENTRON PAC1020 96X96 mm Power Monitoring Device Panel mount type for measurement.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

7KM1020-0BA01-1DA0 SIEMENS SENTRON PAC1020 96X96 mm Power Monitoring Device Panel mount type for measurement..

7KM1020-0BA01-1DA0

SIEMENS

SENTRON PAC1020 96X96 mm Power Monitoring Device Panel mount type for measurement of electr. values Protocol: Modbus RTU With graphical display Un max: 400/230V 45-65Hz Input current 5A AC Power Supply 85V - 276V AC Terminal blocks

SENTRON PAC1020 96X96 mm Power Monitoring Device Panel mount type for measurement of electr. values Protocol: Modbus RTU With graphical display A max: 400/230V 45-65Hz Input current 5A AC Power Supply 85V - 276V AC Terminal blocks. Cancelations and returns limited. Consult conditions.

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > SENTRON PAC network analyzers. Energy Management Software

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $395.45
Unit price: $395.45
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

SENTRON PAC1020 96X96 mm Power Monitoring Device Panel mount type for measurement of electr. values Protocol: Modbus RTU With graphical display Un max: 400/230V 45-65Hz Input current 5A AC Power Supply 85V - 276V AC Terminal blocks
Model
product brand nameSENTRON
design of the productbasic
product type designationMeasuring instrument
Measurements
measuring procedure
● for voltage measurementTRMS
● for current measurementTRMS
type of measured value detectioncomplete
voltage curveSinusoidal or distorted
measurable line frequency
● initial value45 Hz
● full-scale value65 Hz
operating mode for measured value detection automatic line frequency detectionYes
operating mode for measured value detection
● set at 50 HzNo
● set to 60 HzNo
Supply voltage
design of the power supplyWide-range power supply
type of voltage of the supply voltageAC/DC
Degree of protection protection class
protection class IP on the frontIP40
operating resource protection class when installedII
Suitability
suitability for operationInstallation in stationary control panels in closed rooms
Product Functions
product function
● voltage measurementYes
● current measurementYes
● active power measurementYes
● reactive power measurementYes
● frequency measurementYes
Display and operation
design of the displayLCD
height of the display56 mm
width of the display74 mm
color of the background of the displaywhite
illuminance of display backlight adjustableYes
display contrast adjustableYes
number of keys4
Communication
number of interfaces according to Fast Ethernet1
Fault limits
reference condition for metering accuracyaccording to IEC62053-21
formula for relative total measurement inaccuracy
● for measured variable voltage0.50%
● for measured variable current+/- 0,5 %
● for measured variable active power1%
● for measured variable reactive power2%
● for measured variable output factor0.50%
● for measured variable active energyclass 1 according to IEC62053-21
● for measured variable reactive energy2%
Inputs Outputs
number of digital inputs1
design of the switching inputelectronic, passive
type of electrical connection at the digital inputsscrew-type terminals
operating conditions for digital inputs external voltage supplyYes
input voltage at digital input at DC maximum30 V
number of digital outputs1
type of switching outputelectronic, passive
digital output versionswitching or pulse output function
operating voltage as output voltage at DC maximum permissible30 V
type of electrical connection at the digital outputsscrew-type terminals
output current
● at the digital outputs at DC limited to 100 ms maximum130 mA
internal resistance at the digital outputs55 Ω
standard for pulse emitteraccording to IEC62053-31
pulse duration
● initial value500 ms
● full-scale value30 ms
adjustable time period minimum10 ms
switching frequency at digital output maximum17 Hz
property of the output short-circuit proofYes
Measuring inputs
measurable supply voltage between (PE)N and L at AC maximum rated value230 V
measurable supply voltage between (PE)N and L at AC
● minimum11.5 V
● maximum280 V
measurable supply voltage between the line conductors at AC maximum rated value400 V
voltage measuring range extension with external voltage transformersyes
line conductors and neutral conductors internal resistance for voltage measurement1.5 MΩ
measuring category for voltage measurementCATIII
measurable current
● 1 at AC rated value1 A
● 2 at AC rated value5 A
relative measurable current at AC
● minimum10 %
● maximum120 %
current measuring range extension with external current transformersyes
zero point suppression for current measurement0 ... 10 %
measuring category for current measurementCATIII
Connections
type of electrical connection
● at the measurement inputs for voltagescrew-type terminals
● at the measurement inputs for currentscrew-type terminals
Mechanical Design
fastening method standard rail mountingNo
size of Power Monitoring Devicesize 96
height96 mm
width96 mm
depth42 mm
installation depth42 mm
net weight240 g
mounting positionvertical
Environmental conditions
ambient temperature during operation
● minimum-10 °C
● maximum55 °C
ambient temperature during storage
● minimum-25 °C
● maximum70 °C
relative humidity at 25 °C without condensation during operation maximum75 %
installation altitude at height above sea level maximum2 000 m
degree of pollution2

Downloads and manuals

General Product ApprovalDeclaration of Conformityother

Confirmation

EAC

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Miscellaneous

Further information
Information- and Downloadcenter (catalogues, leaflets,...)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/2/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)7KM1020-0BA01-1DA0
Product DescriptionSENTRON PAC1020 96X96 mm Power Monitoring Device Panel mount type for measurement of electr. values Protocol: Modbus RTU With graphical display Un max: 400/230V 45-65Hz Input current 5A AC Power Supply 85V - 276V AC Terminal blocks
Product familySENTRON 7KM PAC Measuring Devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group15N / 1DD
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works2 Day/Days
Net Weight (kg)0,321 Kg
Packaging Dimension112,00 x 132,00 x 80,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4001869576800
UPCNot available
Commodity Code90303370
LKZ_FDB/ CatalogIDLV10
Product Group5313
Group CodeP360
Country of originChina
Compliance with the substance restrictions according to RoHS directiveSince: 01.01.2020
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-20-03-01
eClass7.127-20-03-01
eClass827-20-03-01
eClass927-20-03-01
eClass9.127-20-03-01
ETIM5EC002301
ETIM6EC002301
ETIM7EC002301
ETIM8EC002301

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.