6GK1411-2AB10 SIEMENS SIMATIC NET, IE/AS-i Link PN IO Gateway IE/AS-i with master profile M3, M4 according t.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

6GK1411-2AB10 SIEMENS SIMATIC NET, IE/AS-i Link PN IO Gateway IE/AS-i with master profile M3, M4 according t..

6GK1411-2AB10

SIEMENS

SIMATIC NET, IE/AS-i Link PN IO Gateway IE/AS-i with master profile M3, M4 according to AS-i specification V3.0 for integration in PROFINET IO Single master with display IP20

More details


CONTROL AND CONTACTORS > AS-Interface switchgear, SIMOCODE

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC001423 - PLC communication module

Value Unit
Category according to EN 954-1 (EF006782) -
Number of HW-interfaces industrial Ethernet (EF003020) 2
Number of interfaces PROFINET (EF006932) 2
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces other (EF003027) 1
With optical interface (EF003028) false
Supporting protocol for TCP/IP (EF003050) true
Supporting protocol for PROFIBUS (EF003052) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) true
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) false
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for PROFINET IO (EF007525) true
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) false
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) false
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
Redundancy (EF003156) false
Type of data transmission (EF008225) Other
Transmission rate (EF003271) 167.0kBit/s
With potential separation (EF003272) true
SIL according to IEC 61508 (EF009889) None
Suitable for safety functions (EF001597) false
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 90.0mm
Height (EF000040) 132.0mm
Depth (EF000049) 88.5mm


SIMATIC NET, IE/AS-i Link PN IO Gateway IE/AS-i with master profile M3, M4 according to AS-i specification V3.0 for integration in PROFINET IO Single master with display IP20
General technical data
Product designationPROFINET IO/AS-Interface Link
Product type designationIE/AS-i LINK PN IO (single master)
Protection class IPIP20
Type of electrical connection of the AS-InterfaceScrew-type connection
Type of voltage supplyvia AS-i or 24 V DC
Operating condition separate power supply 24 VNo
Supply voltage from optional external supply voltage at DCV24
Consumed current
● from profile conductors of the AS-Interface
— at 30 V maximummA320
— at 24 V with AS-i Power24V maximummA320
Power loss [W]W9.6
Insulation voltage rated valueV500
Product function suitable for AS-i Power24VNo
● Notefrom product status 4 / firmware V2.2
Product feature redundancy capabilityNo
Product function
● web-based managementYes
● Diagnostics via emailYes
● Galvanic isolationYes
Display version
● as status display by LEDSF, BF, ON, APF, CER, AUP, CM
● as status indication through displayLCD display, full graphic, backlighting, 128 x 64 pixels
Type of configuration of the AS-InterfaceOperator display, integrated web server, STEP7, GSD, command interface
Communication/ Protocol
Version of the AS-Interface specificationV 3.0
AS-Interface master profile is supportedM4 (in acc. with AS-interface specification V 3.0)
Type of data transmissionPROFINET
Number of interfaces
● as AS-Interface1
● acc. to RS 4850
● acc. to Industrial Ethernet2
● acc. to PROFINET2
● acc. to wireless0
● acc. to USB0
● other1
Product component optical interfaceNo
Protocol is supported
● ASIsafe (Safety at work) protocolNo
● PROFIsafe protocolNo
● PROFIBUS protocolNo
● PROFINET IO protocolYes
● PROFINET CBA protocolNo
● TCP/IPYes
● SNMPYes
Standard for wireless communication IEEE 802.11No
Inputs/ Outputs
Number of inputs for AS Interface maximum496
Number of outputs for AS Interface maximum496
Number of AS-i slaves per AS-Interface maximum62
Bus cycle time of the AS-Interface
● for 31 slavesms5
● for 62 slavesms10
Access to digital I/O datavia process image/peripheral addresses
Access to analog I/O datavia process diagram/peripheral addresses and data record transfer
Mechanical data
Widthmm90
Heightmm132
Depthmm88.5
Mounting typesnap-on fastening on 35 mm standard rail
Module formatIP20
Ambient conditions
Ambient temperature
● if installed on horizontal mounting rail°C0 ... 60
● during transport°C-30 ... +70
● during storage°C-30 ... +70
Relative humidity at 25 °C during operation maximum%95
Installation altitude at height above sea level maximumm3 000
Safety related data
Suitability for use safety-related functionNo
Explosion protection marking for intrinsic safety of related equipment
● EEx iaNo
● EEx ibNo
Explosion protection category for gasnone
Explosion protection category for dustnone
Certificates/ approvals
General Product ApprovalEMCFor use in hazardous locationsDeclaration of Conformity

FM

UL

EAC

RCM

ATEX-EC-Type-Examination-Certificate

EC/EU-Declaration of Conformity

Declaration of ConformityShipping Approvalother

Miscellaneous

BV / Bureau Veritas

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:08/15/2020


Product
Article Number (Market Facing Number)6GK1411-2AB10
Product DescriptionSIMATIC NET, IE/AS-i Link PN IO Gateway IE/AS-i with master profile M3, M4 according to AS-i specification V3.0 for integration in PROFINET IO Single master with display IP20
Product familyIE/AS‑i Link PN IO
Product Lifecycle (PLM)PM300:Active Product
PLM Effective DateProduct phase-out since: 01.10.2020
Notes
Sucessor:Modularer Aufbau mit 3RK7137-6SA00-0BC1: CM AS-i Master ST in ET 200SP PROFINET
Price data
Price Group42C
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99H
Standard lead time ex-works1 Day/Days
Net Weight (kg)0,535 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension139,00 x 174,00 x 136,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4019169852173
UPC040892555028
Commodity Code85176200
LKZ_FDB/ CatalogIDCC-IC10
Product Group5323
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-24-22-08
eClass7.127-24-22-08
eClass827-24-22-08
eClass927-24-22-08
eClass9.127-24-22-08
ETIM4EC001423
ETIM5EC001423
ETIM6EC001423
ETIM7EC001423
IDEA43564
UNSPSC1432-15-17-05
UNSPSC1532-15-17-05

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.