SIMATIC ET 200SP Open Controllers, CPU 1515SP PC. 4 GB RAM, 30 GB CFAST with WES 7 P 64 bit pre-installed, with S7-1500 software controller CPU 1505SP F pre-installed, Interfaces: 1x slot CFAST, 1x slot SD/MMC, 1x connection for ET 200SP bus adapter PROFINET 1x 10/100/1000 Mbit/s Ethernet, 3x USB, 1x DVI-I graphics card connection, Documentation on DVD, Restore DVD
AUTOMATION SYSTEMS > SIMATIC S7-1500 / F Safety / RH Redundant / Open Controller / Software Controller (without I / O)
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Value | Unit | |
|---|---|---|
| Max. input current DC (EF007362) | - | A |
| Type of electric connection (EF003961) | - | |
| Category according to EN 954-1 (EF006782) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| With potential separation (EF003272) | - | |
| SIL according to IEC 61508 (EF009889) | - | |
| Performance level according to EN ISO 13849-1 (EF007399) | - | |
| Number of slots (EF003077) | - | |
| With integrated power supply (EF003338) | true | |
| Input voltage at AC 50 Hz (EF007118) | ['-', '-'] | V |
| Input voltage at AC 60 Hz (EF007119) | ['-', '-'] | V |
| Input voltage at DC (EF007120) | ['19.2', '28.8'] | V |
| Type of voltage (input voltage) (EF003033) | DC | |
| Max. input current AC 50 Hz (EF007360) | - | A |
| Max. input current AC 60 Hz (EF007361) | - | A |
| Output voltage at AC 50 Hz (EF006999) | ['-', '-'] | V |
| Output voltage at AC 60 Hz (EF007000) | ['-', '-'] | V |
| Output voltage at DC (EF007001) | ['-', '-'] | V |
| Type of output voltage (EF008222) | - | |
| Max. output current AC 50 Hz (EF007351) | - | A |
| Max. output current AC 60 Hz (EF007352) | - | A |
| Max. output current DC (EF007353) | - | A |
| Number of HW-interfaces industrial Ethernet (EF003020) | 2 | |
| Number of interfaces PROFINET (EF006932) | 1 | |
| Number of HW-interfaces RS-232 (EF003021) | 0 | |
| Number of HW-interfaces RS-422 (EF003022) | 0 | |
| Number of HW-interfaces RS-485 (EF003023) | 1 | |
| Number of HW-interfaces serial TTY (EF003024) | 0 | |
| Number of HW-interfaces USB (EF003025) | 3 | |
| Number of HW-interfaces parallel (EF003026) | 0 | |
| Number of HW-interfaces Wireless (EF006933) | 0 | |
| Number of HW-interfaces other (EF003027) | 0 | |
| With optical interface (EF003028) | - | |
| Supporting protocol for PROFIBUS (EF003052) | true | |
| Supporting protocol for CAN (EF003053) | false | |
| Supporting protocol for INTERBUS (EF003054) | false | |
| Supporting protocol for ASI (EF003051) | false | |
| Supporting protocol for KNX (EF003055) | false | |
| Supporting protocol for Modbus (EF003057) | true | |
| Supporting protocol for Data-Highway (EF003058) | false | |
| Supporting protocol for DeviceNet (EF003059) | false | |
| Supporting protocol for SUCONET (EF003060) | false | |
| Supporting protocol for LON (EF003017) | false | |
| Supporting protocol for SERCOS (EF006657) | false | |
| Supporting protocol for PROFINET IO (EF007525) | true | |
| Supporting protocol for PROFINET CBA (EF007524) | false | |
| Supporting protocol for Foundation Fieldbus (EF007522) | false | |
| Supporting protocol for EtherNet/IP (EF007521) | false | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false | |
| Supporting protocol for DeviceNet Safety (EF007520) | false | |
| Supporting protocol for INTERBUS-Safety (EF006662) | false | |
| Supporting protocol for PROFIsafe (EF007526) | false | |
| Supporting protocol for SafetyBUS p (EF007527) | false | |
| Supporting protocol for other bus systems (EF003062) | false | |
| Radio standard Bluetooth (EF007178) | false | |
| Radio standard WLAN 802.11 (EF007179) | false | |
| Radio standard GPRS (EF008523) | false | |
| Radio standard GSM (EF008524) | false | |
| Radio standard UMTS (EF008525) | false | |
| IO link master (EF007298) | false | |
| System accessory (EF004118) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| With pluggable modules, digital I/O (EF003078) | true | |
| With pluggable modules, analogue I/O (EF003079) | true | |
| With pluggable modules, communication modules (EF003080) | true | |
| With pluggable modules, function and technology modules (EF003081) | true | |
| With pluggable modules, central modules (EF003082) | true | |
| With pluggable modules, others (EF003083) | true | |
| Fieldbus connection over separate bus coupler possible (EF004002) | true | |
| With bus coupler for modular station connection (EF003990) | true | |
| Rail mounting possible (EF003972) | true | |
| Wall mounting/direct mounting (EF007020) | true | |
| Front build in possible (EF007016) | - | |
| Rack-assembly possible (EF007018) | - | |
| Suitable for safety functions (EF001597) | false | |
| Appendant operation agent (Ex ia) (EF004141) | false | |
| Appendant operation agent (Ex ib) (EF004142) | false | |
| Explosion safety category for gas (EF003997) | ATEX gas-ex-protection, Cat. 3G | |
| Explosion safety category for dust (EF003998) | None | |
| Width (EF000008) | 160.0 | mm |
| Height (EF000040) | 117.0 | mm |
| Depth (EF000049) | 75.0 | mm |
| SIMATIC ET 200SP Open Controllers, CPU 1515SP PC. 4 GB RAM, 30 GB CFAST with WES 7 P 64 bit pre-installed, with S7-1500 software controller CPU 1505SP F pre-installed, Interfaces: 1x slot CFAST, 1x slot SD/MMC, 1x connection for ET 200SP bus adapter PROFINET 1x 10/100/1000 Mbit/s Ethernet, 3x USB, 1x DVI-I graphics card connection, Documentation on DVD, Restore DVD | ||
| General information | ||
| Product type designation | CPU 1515SP PC | |
| HW functional status | FS05 | |
| Firmware version | V2.1 | |
| Engineering with | ||
| ● STEP 7 TIA Portal configurable/integrated from version | V14 SP1 | |
| Installed software | ||
| ● Visualization | No | |
| ● Control | S7-1500 Software Controller CPU 1505SP V2.1 | |
| Configuration control | ||
| via dataset | Yes | |
| Control elements | ||
| Mode selector switch | 1 | |
| Supply voltage | ||
| Type of supply voltage | 24 V DC | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes | |
| Mains buffering | ||
| ● Mains/voltage failure stored energy time | 5 ms | |
| Input current | ||
| Current consumption (rated value) | 1.5 A; Full processor load, incl. ET 200SP modules and using USB | |
| Current consumption (in no-load operation), typ. | 0.6 A | |
| Inrush current, max. | 4.7 A; Rated value | |
| Power | ||
| Active power input, max. | 36 W; incl. ET 200SP modules and using USB | |
| Infeed power to the backplane bus | 8.75 W | |
| Power loss | ||
| Power loss, typ. | 15 W; without ET 200SP modules and without using USB | |
| Processor | ||
| Processor type | Dual-Core 1 GHz, AMD G Series APU T40E | |
| Memory | ||
| Type of memory | DDR3-SDRAM | |
| Main memory | 4 GB RAM | |
| CFast memory card | Yes; 30 GB flash memory | |
| SIMATIC memory card required | No | |
| Work memory | ||
| ● integrated (for program) | 1 Mbyte | |
| ● integrated (for data) | 5 Mbyte | |
| ● integrated (for CPU function library of CPU Runtime) | 10 Mbyte | |
| Load memory | ||
| ● integrated (on PC mass storage) | 320 Mbyte | |
| Backup | ||
| ● with UPS | Yes; all memory areas declared retentive | |
| ● with non-volatile memory | Yes | |
| CPU processing times | ||
| for bit operations, typ. | 10 ns | |
| for word operations, typ. | 12 ns | |
| for fixed point arithmetic, typ. | 16 ns | |
| for floating point arithmetic, typ. | 64 ns | |
| CPU-blocks | ||
| Number of elements (total) | 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements | |
| DB | ||
| ● Number, max. | 5 999; Number range: 1 to 65535 | |
| ● Size, max. | 5 Mbyte | |
| FB | ||
| ● Number, max. | 5 998; Number range: 1 to 65535 | |
| ● Size, max. | 512 kbyte | |
| FC | ||
| ● Number, max. | 5 999; Number range: 1 to 65535 | |
| ● Size, max. | 512 kbyte | |
| OB | ||
| ● Size, max. | 1 048 kbyte | |
| ● Number of free cycle OBs | 100 | |
| ● Number of time alarm OBs | 20 | |
| ● Number of delay alarm OBs | 20 | |
| ● Number of cyclic interrupt OBs | 20 | |
| ● Number of process alarm OBs | 50 | |
| ● Number of DPV1 alarm OBs | 3 | |
| ● Number of isochronous mode OBs | 1 | |
| ● Number of technology synchronous alarm OBs | 2 | |
| ● Number of startup OBs | 100 | |
| ● Number of asynchronous error OBs | 4 | |
| ● Number of synchronous error OBs | 2 | |
| ● Number of diagnostic alarm OBs | 1 | |
| Nesting depth | ||
| ● per priority class | 24 | |
| Counters, timers and their retentivity | ||
| S7 counter | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC counter | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| S7 times | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC timer | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| Data areas and their retentivity | ||
| Retentive data area (incl. timers, counters, flags), max. | 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes | |
| Flag | ||
| ● Number, max. | 16 kbyte | |
| ● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | |
| Data blocks | ||
| ● Retentivity adjustable | Yes | |
| ● Retentivity preset | No | |
| Local data | ||
| ● per priority class, max. | 64 kbyte; max. 16 KB per block | |
| Address area | ||
| Number of IO modules | 8 192 | |
| I/O address area | ||
| ● Inputs | 32 kbyte; All inputs are in the process image | |
| ● Outputs | 32 kbyte; All outputs are in the process image | |
| of which per assigned PC interface | ||
| — Inputs (volume) | 8 kbyte | |
| — Outputs (volume) | 8 kbyte | |
| Subprocess images | ||
| ● Number of subprocess images, max. | 32 | |
| Hardware configuration | ||
| Integrated power supply | Yes | |
| Number of distributed IO systems | 20 | |
| Number of DP masters | ||
| ● Via CM | 1 | |
| Rack | ||
| ● Modules per rack, max. | 64; CPU 1515SP PC + 64 modules + server module | |
| ● Number of lines, max. | 1 | |
| PtP CM | ||
| ● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
| Time of day | ||
| Clock | ||
| ● Type | Hardware clock | |
| ● Hardware clock (real-time) | Yes; Resolution: 1 s | |
| ● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
| ● Deviation per day, max. | 10 s; Typ.: 2 s | |
| Clock synchronization | ||
| ● supported | Yes | |
| ● to DP, master | No | |
| ● on Ethernet via NTP | Yes | |
| ● on Windows clock, slave | Yes | |
| Interfaces | ||
| Number of industrial Ethernet interfaces | 2 | |
| Number of PROFINET interfaces | 1 | |
| Number of PROFIBUS interfaces | 1 | |
| Number of RS 485 interfaces | 1; Via CM DP module | |
| Number of USB interfaces | 3; 3x USB 2.0 on the front, 500 mA each - of which 2x 500 mA and 1x 100 mA simultaneously | |
| Number of SD card slots | 1 | |
| Video interfaces | ||
| ● Graphics interface | 1x DVI-I | |
| 1. Interface | ||
| Interface type | PROFINET | |
| automatic detection of transmission rate | Yes | |
| Autonegotiation | Yes | |
| Autocrossing | Yes | |
| Number of connections | 88 | |
| Interface types | ||
| ● Number of ports | 2 | |
| ● integrated switch | Yes | |
| ● RJ 45 (Ethernet) | Yes; Via BusAdapter BA 2x RJ45 | |
| — Transmission rate, max. | 100 Mbit/s | |
| — Industrial Ethernet status LED | Yes | |
| ● BusAdapter (PROFINET) | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | |
| Protocols | ||
| ● PROFINET IO Controller | Yes | |
| ● PROFINET IO Device | Yes | |
| ● SIMATIC communication | Yes | |
| ● Open IE communication | Yes | |
| ● Web server | Yes | |
| PROFINET IO Controller | ||
| Services | ||
| — Isochronous mode | Yes | |
| — shortest clock pulse | 500 µs | |
| — IRT | Yes | |
| — MRP | Yes | |
| — MRPD | Yes | |
| — Prioritized startup | Yes; Max. 32 PROFINET devices | |
| — Number of connectable IO Devices, max. | 128 | |
| — Of which IO devices with IRT, max. | 64 | |
| — of which in line, max. | 64 | |
| — Number of connectable IO Devices for RT, max. | 128 | |
| — of which in line, max. | 128 | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | |
| — IO Devices changing during operation (partner ports), supported | Yes | |
| — Number of IO Devices per tool, max. | 8 | |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
| Update time for IRT | ||
| — for send cycle of 500 µs | 500 µs to 8 ms | |
| — for send cycle of 1 ms | 1 ms to 16 ms | |
| — for send cycle of 2 ms | 2 ms to 32 ms | |
| — for send cycle of 4 ms | 4 ms to 64 ms | |
| — With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) | |
| Update time for RT | ||
| — for send cycle of 500 µs | 500 µs to 256 ms | |
| — for send cycle of 1 ms | 1 ms to 512 ms | |
| — for send cycle of 2 ms | 2 ms to 512 ms | |
| — for send cycle of 4 ms | 4 ms to 512 ms | |
| PROFINET IO Device | ||
| Services | ||
| — Isochronous mode | No | |
| — IRT | Yes | |
| — MRP | Yes | |
| — MRPD | Yes | |
| — Prioritized startup | Yes | |
| — Shared device | Yes | |
| — Number of IO Controllers with shared device, max. | 4 | |
| 2. Interface | ||
| Interface type | Integrated Ethernet interface | |
| automatic detection of transmission rate | Yes | |
| Autonegotiation | Yes | |
| Autocrossing | Yes | |
| Interface types | ||
| ● Number of ports | 1 | |
| ● RJ 45 (Ethernet) | Yes; Integrated | |
| — Transmission rate, max. | 1 000 Mbit/s | |
| — Industrial Ethernet status LED | No | |
| 3. Interface | ||
| Interface type | PROFIBUS with CM DP | |
| Number of connections via this interface | 44 | |
| Interface types | ||
| ● RS 485 | Yes | |
| Protocols | ||
| ● PROFIBUS DP master | Yes | |
| ● PROFIBUS DP slave | Yes | |
| ● SIMATIC communication | Yes | |
| PROFIBUS DP master | ||
| ● Number of DP slaves, max. | 125 | |
| Services | ||
| — Equidistance | No | |
| — Isochronous mode | No | |
| Interface types | ||
| RS 485 | ||
| ● Transmission rate, max. | 12 Mbit/s | |
| Protocols | ||
| Number of connections | ||
| ● Number of connections, max. | 88 | |
| ● Number of connections reserved for ES/HMI/web | 10 | |
| ● Number of S7 routing paths | 16 | |
| Redundancy mode | ||
| Media redundancy | ||
| — Switchover time on line break, typ. | 200 ms | |
| — Number of stations in the ring, max. | 50 | |
| SIMATIC communication | ||
| ● PG/OP communication | Yes | |
| ● S7 routing | Yes | |
| ● S7 communication, as server | Yes | |
| ● S7 communication, as client | Yes | |
| ● User data per job, max. | 64 kbyte | |
| Open IE communication | ||
| ● TCP/IP | Yes | |
| — Data length, max. | 64 kbyte | |
| ● ISO-on-TCP (RFC1006) | Yes | |
| — Data length, max. | 64 kbyte | |
| ● UDP | Yes | |
| — Data length, max. | 1 472 kbyte | |
| ● SNMP | Yes | |
| ● DCP | Yes | |
| ● LLDP | Yes | |
| Web server | ||
| ● HTTP | Yes; Via Windows and PROFINET interface | |
| ● HTTPS | Yes; Only via PROFINET interface | |
| OPC UA | ||
| ● OPC UA Server | Yes; Data access (read, write, subscribe), runtime license required | |
| — Application authentication | Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
| — Security policies | Yes; Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
| — User authentication | Yes; "anonymous" or by user name & password | |
| Further protocols | ||
| ● MODBUS | Yes; MODBUS TCP | |
| S7 message functions | ||
| Number of login stations for message functions, max. | 32 | |
| Program alarms | Yes | |
| Number of configurable program messages, max. | 10 000 | |
| Number of simultaneously active program alarms | ||
| ● Number of program alarms | 1 000 | |
| ● Number of alarms for system diagnostics | 200 | |
| ● Number of alarms for motion technology objects | 160 | |
| Test commissioning functions | ||
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems | |
| Status block | Yes; up to 8 simultaneously | |
| Single step | No | |
| Status/control | ||
| ● Status/control variable | Yes | |
| ● Variables | Inputs, outputs, memory bits, DB, times, counters | |
| ● Number of variables, max. | ||
| — of which status variables, max. | 200 | |
| — of which control variables, max. | 200 | |
| Forcing | ||
| ● Forcing | Yes | |
| ● Forcing, variables | Inputs, outputs | |
| ● Number of variables, max. | 200 | |
| Diagnostic buffer | ||
| ● present | Yes | |
| ● Number of entries, max. | 1 000 | |
| — of which powerfail-proof | 300 | |
| Traces | ||
| ● Number of configurable Traces | 4 | |
| ● Memory size per trace, max. | 512 kbyte | |
| Interrupts/diagnostics/status information | ||
| Diagnostics indication LED | ||
| ● RUN/STOP LED | Yes | |
| ● ERROR LED | Yes | |
| ● MAINT LED | Yes | |
| Supported technology objects | ||
| Motion Control | Yes | |
| ● Number of available Motion Control resources for technology objects | 2 400 | |
| ● Required Motion Control resources | ||
| — per speed-controlled axis | 40; per axis | |
| — per positioning axis | 80; per axis | |
| — per synchronous axis | 160; per axis | |
| — per external encoder | 80; per external encoder | |
| — per output cam | 20; per cam | |
| — per cam track | 160; per cam track | |
| — per probe | 40; per probe | |
| ● Positioning axis | ||
| — Number of positioning axes at motion control cycle of 4 ms (typical value) | 5 | |
| — Number of positioning axes at motion control cycle of 8 ms (typical value) | 12 | |
| Controller | ||
| ● PID_Compact | Yes; Universal PID controller with integrated optimization | |
| ● PID_3Step | Yes; PID controller with integrated optimization for valves | |
| ● PID-Temp | Yes; PID controller with integrated optimization for temperature | |
| Counting and measuring | ||
| ● High-speed counter | Yes | |
| Standards, approvals, certificates | ||
| CE mark | Yes | |
| CSA approval | Yes | |
| cULus | Yes | |
| FM approval | Yes | |
| RCM (formerly C-TICK) | Yes | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● min. | 0 °C | |
| ● max. | Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load | |
| ● horizontal installation, min. | 0 °C | |
| ● horizontal installation, max. | 60 °C | |
| ● vertical installation, min. | 0 °C | |
| ● vertical installation, max. | 50 °C; With max. 32 ET 200SP modules and 3x 100 mA USB load | |
| Ambient temperature during storage/transportation | ||
| ● min. | -40 °C | |
| ● max. | 70 °C | |
| Vibrations | ||
| ● Operation, tested according to IEC 60068-2-6 | Yes | |
| ● Transport, tested acc. to IEC 60068-2-6 | Yes | |
| Shock testing | ||
| ● tested according to IEC 60068-2-6 | Yes | |
| ● tested according to IEC 60068-2-27 | Yes | |
| ● tested according to IEC 60068-2-29 | Yes | |
| ● Storage/transport, tested acc. to IEC 60068-2-27 | Yes | |
| Operating systems | ||
| pre-installed operating system | Windows Embedded Standard 7 P 64-bit | |
| Configuration | ||
| Programming | ||
| Programming language | ||
| — LAD | Yes | |
| — FBD | Yes | |
| — STL | Yes | |
| — SCL | Yes | |
| — CFC | No | |
| — GRAPH | Yes | |
| Know-how protection | ||
| ● User program protection/password protection | Yes | |
| ● Copy protection | Yes | |
| ● Block protection | Yes | |
| Access protection | ||
| ● Protection level: Write protection | Yes | |
| ● Protection level: Read/write protection | Yes | |
| ● Protection level: Complete protection | Yes | |
| Cycle time monitoring | ||
| ● lower limit | adjustable minimum cycle time | |
| ● upper limit | adjustable maximum cycle time | |
| Open Development interfaces | ||
| ● Size of ODK SO file, max. | 3.8 Mbyte | |
| Peripherals/Options | ||
| SD card | Optionally for additional mass storage | |
| Dimensions | ||
| Width | 160 mm | |
| Height | 117 mm | |
| Depth | 75 mm | |
| Weights | ||
| Weight, approx. | 0.83 kg | |
| last modified: | 08/24/2020 | |
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6ES7677-2AA41-0FB0 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIMATIC ET 200SP Open Controllers, CPU 1515SP PC. 4 GB RAM, 30 GB CFAST with WES 7 P 64 bit pre-installed, with S7-1500 software controller CPU 1505SP F pre-installed, Interfaces: 1x slot CFAST, 1x slot SD/MMC, 1x connection for ET 200SP bus adapter PROFINET 1x 10/100/1000 Mbit/s Ethernet, 3x USB, 1x DVI-I graphics card connection, Documentation on DVD, Restore DVD | ||||||||||||||||||||||||||||||||||||
| Product family | CPU 1515SP PC | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Price Group | 215 | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : 5A992 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 5 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,088 Kg | ||||||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 14,20 x 18,90 x 9,20 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | CM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4047623405061 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766010927 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371091 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | STWINAC | ||||||||||||||||||||||||||||||||||||
| Product Group | 4A62 | ||||||||||||||||||||||||||||||||||||
| Group Code | R111 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 05.02.2015 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 6ES7677-2AA41-0FB0 EN_6ES7677-2AA41-0FB0.pdf | 145 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.