ANUNCIAR
5SV3444-8 SIEMENS Residual current operated circuit breaker, 4-pole, type A, selective, In: 40 A, 100 mA, Un.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

5SV3444-8 SIEMENS Residual current operated circuit breaker, 4-pole, type A, selective, In: 40 A, 100 mA, Un..

5SV3444-8

SIEMENS

Residual current operated circuit breaker, 4-pole, type A, selective, In: 40 A, 100 mA, Un AC: 400 V

DIFFERENTIAL SWITCH TYPE A 40A 3+N POL. 100MA 400V 4MOD. SELECTIVE. Cancelations and returns limited. Consult conditions.

More details


Circuit breakers and fuses > Residual current circuit breaker (RCCB)

POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Tertiary differential switches up to 80 A

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $451.48
Unit price: $451.48
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

Residual current operated circuit breaker, 4-pole, type A, selective, In: 40 A, 100 mA, Un AC: 400 V
Model
product brand nameSENTRON
product designationRCCB
design of the productSelective
General technical data
number of poles4
size of installation devices / according to DIN 438801
mechanical service life (switching cycles) / typical10 000
short-circuit current / of series fuse / maximum permissible100 A
short-circuit current rating10 kA
switching function / short-term delayedNo
overvoltage categoryIII
Supply voltage
supply voltage / for testing equipment / minimum100 V
value range / of the supply voltage frequency50 Hz
value range / of the operating frequency50/60 Hz
value range / of the supply voltage / at AC230/400 V
Protection class
protection class IPIP20, if the distribution board is installed, with connected conductors
Switching capacity
switching capacity current
● according to IEC 61008-1 / rated value0.8 kA
Dissipation
power loss [W]
● for rated value of the current / at AC / in hot operating state / per pole1.8 W
● maximum5.4 W
Current
tripping fault current / rated value100 mA
operational current
● at 40 °C / rated value40 A
● at 45 °C / rated value40 A
● at 50 °C / rated value40 A
● at 55 °C / rated value40 A
● at 60 °C / rated value40 A
● at 65 °C / rated value40 A
● at 70 °C / rated value40 A
● at AC / rated value40 A
residual current typeA
let-through current / permissible5 200 A
I2t value / permissible58 000 A²·s
surge current resistance / rated value5 kA
Product details
product feature / silicon-freeYes
product extension / installable / supplementary devicesYes
Connections
connectable conductor cross-section / solid
● minimum0.75 mm²
● maximum35 mm²
connectable conductor cross-section / stranded
● minimum0.75 mm²
● maximum35 mm²
tightening torque / with screw-type terminals
● minimum2.5 N·m
● maximum3 N·m
position / of power supply cordtop or bottom
Mechanical Design
height90 mm
width72 mm
depth70 mm
installation depth70 mm
number of modular width units4
fastening methodDIN rail (REG)
mounting positionany
Environmental conditions
ambient temperature / during operation
● minimum-25 °C
● maximum45 °C
ambient temperature / during storage
● minimum permissible-40 °C
● maximum permissible75 °C
number of test cycles / for environmental testing / according to IEC 60068-2-3028

Downloads and manuals

General Product Approval

Confirmation

CCC

ÖVE

VDE

Miscellaneous

EAC

Declaration of ConformityTest CertificatesotherRailway

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Miscellaneous

Miscellaneous

Vibration and Shock

Confirmation

Dangerous Good

Transport Information

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/15/2022


Additional data

Product
Article Number (Market Facing Number)5SV3444-8
Product DescriptionResidual current operated circuit breaker, 4-pole, type A, selective, In: 40 A, 100 mA, Un AC: 400 V
Product familyRCCBs
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group11C / 1AH
Surcharge for Raw MaterialsNone
Metal FactorL-A-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works70 Day/Days
Net Weight (kg)0,378 Kg
Packaging Dimension97,00 x 78,00 x 85,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4001869430720
UPCNot available
Commodity Code85362010
LKZ_FDB/ CatalogIDLV10.1
Product Group5511
Group CodeP310
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.06.2006
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Silicic acid, lead salt

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-14-22-01
eClass7.127-14-22-01
eClass827-14-22-01
eClass927-14-22-01
eClass9.127-14-22-01
ETIM5EC000003
ETIM6EC000003
ETIM7EC000003
ETIM8EC000003
UNSPSC1439-12-16-01
UNSPSC1539-12-16-01

ETIM data

ETIM: EC000003 - Residual current circuit breaker (RCCB)

Value Unit
Number of poles (EF001391) 4
Rated voltage (EF000228) 400V
Rated current (EF000227) 40A
Rated fault current (EF002358) 0.1mA
Rated insulation voltage Ui (EF001366) -V
Mounting method (EF000003) DIN rail
Leakage current type (EF002560) A
Selective protection (EF002561) true
Short-time delayed tripping (EF003604) false
Short-circuit breaking capacity (Icw) (EF002562) 10.0kA
Surge current capacity (EF002564) 5.0kA
Frequency (EF005455) 50 Hz
Additional equipment possible (EF008148) true
With interlocking device (EF007385) true
Degree of protection (IP) (EF005474) IP20
Width in number of modular spacings (EF002950) 4
Built-in depth (EF000218) 70.0mm
Ambient temperature during operating (EF007515) ['-25', '45']°C
Pollution degree (EF002570) -
Connectable conductor cross section multi-wired (EF007343) ['0.75', '35.0']mm²
Connectable conductor cross section solid-core (EF007337) ['0.75', '35.0']mm²
Rated impulse withstand voltage Uimp (EF011980) -kV



Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.