Lightning conductor T1/T2, UN 240/400 V, UC 335/264 V A.C., pluggable protective modules, 3+1 circuit (TN-S, TT), Width 72 mm

3-POLE SURGE DISCHARGER, FOR TN-C NETWORK SYSTEMS (WITHOUT REMOTE WARNING), 50 kA. Manufactured to order. Non-Cancelable Non-Returnable.

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Other Modular Systems

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $692.16
Unit price: $692.16
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

Best sellers

More info



Technical data

Lightning conductor T1/T2, UN 240/400 V, UC 335/264 V A.C., pluggable protective modules, 3+1 circuit (TN-S, TT), Width 72 mm
General data
standardIEC 61643-11: 2011, EN 61643-11: 2012
product designationSurge protection device
SPD classification / according to EN 61643-11
● Test Class I, Type 1Yes
● Test Class II, Type 2Yes
● Test Class III, Type 3No
number of SPD ports1
Product versionCombination surge arresters
design of pole3+N/PE
designation of the protective pathsL-N, L-PE, N-PE
Accessories3 x 5SD7418-3 + 1 x 5SD7418-2
fastening methodDIN rail NS 35
material / of the enclosurePA 6.6 / PBT
size of surge arrester4 TE
Degree of pollution2
overvoltage category / according to IEC 61010-1III
protection class IP / at connection all terminalsIP20
shock acceleration30 gn
vibrational acceleration / at 5 Hz ... 500 Hz / limited to 2,5 h / per axis7.5 gn
Ambient temperature / during operation / minimum permissible ... ambient temperature / during operation / maximum permissible-40 °C ... 80 °C
ambient temperature / during storage and transport-40 °C ... 80 °C
relative humidity / during operation5 % ... 95 %
installation altitude / at height above sea level / maximum2 000 m
Width71.2 mm
Height89.9 mm
depth77.5 mm
net weight634 g
Electrical data
type of distribution systemTT, TN-S
operating voltage230 V
continuous operating voltage
● maximum335 V
● between N and PE264 V
● between L and (PE)N335 V
apparent power consumption / maximum810 mVA
discharge current
● between L and (PE)N / at (8/20) µs12.5 kA
● between L and N / at (8/20) µs50 kA
● between L and PE / at (8/20) µs50 kA
● between L and PE / at (8/20) µs12.5 kA
● between N and PE / at (8/20) µs50 kA
● between N and PE / at (8/20) µs50 kA
total discharge current / at (8/20) µs50 kA
total lightning impulse current / at (10/350) µs50 kA
lightning current peak value / at (10/350) µs
● lightning current peak value / between L and PE12.5 kA
● lightning current peak value / between N and PE50 kA
● lightning current peak value / between L and N12.5 kA
charge of the flash / at (10/350) µs
● charge of the flash / between L and N6.25 A·s
● charge of the flash / between L and PE6.25 A·s
● charge of the flash / between N and PE25 A·s
specific energy of the flash / at (10/350) µs
● between L and N39
● between L and PE39
● between N and PE625
follow current extinguishing capability
● between N and PE100 A (264 V a.c.)
short-circuit rating (SCCR) / at 264 V25 kA
protection level
● between L and N1.2 kV
● between L and PE2 kV
● between N and L1.2 kV
● between N and PE1.7 kV
● between PE and N and/or L1.7 kV
residual voltage
● between L and (PE)N
— at rated value of discharge current / maximum1.2 kV
— at 10 kA / maximum1.1 kV
— at 5 kA / maximum1 kV
— at 3 kA / maximum0.9 kV
● between L and PE
— at rated value of discharge current / maximum2 kV
— at 10 kA / maximum1.5 kV
— at 5 kA / maximum1.2 kV
— at 3 kA / maximum1.1 kV
● between N and PE
— at rated value of discharge current / maximum0.6 kV
— at 10 kA / maximum0.5 kV
— at 5 kA / maximum0.5 kV
— at 3 kA / maximum0.4 kV
response value of the surge voltage / at 6 kV / at (1.2/50) µs
● between N and PE1.7 kV
● response time / between L and (PE)N25 ns
● response time / between N and PE100 ns
adjustable response factor / of tripping current1.6
fuse protection type / at V-shaped connection80 A AC (gG)
fuse protection type / for T-connector160 A AC (gG)
Connections/ Terminals
type of electrical connectionScrew terminal
stripped length16 mm
tightening torque4.3 ... 4.7
stripped length16 mm
connectable conductor cross-section
● for finely stranded conductor1.5 ... 25
● for rigid conductor1.5 ... 35
● finely stranded1.5 ... 25
AWG number / as coded connectable conductor cross section15 ... 2
design of the thread / of the connection screwM5
signal designoptical
NEMA/UL - Data
type of distribution systemTT, TN-S
TOV behavior
● at TOV test voltage (L-N)415 V AC (5 s / withstand mode)
● at TOV test voltage (N-PE)1200 V (200 ms / withstand mode)

Downloads and manuals

combustibility class according to UL 94V0
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator


Additional data

Product
Article Number (Market Facing Number)5SD7414-2
Product DescriptionLightning conductor T1/T2, UN 240/400 V, UC 335/264 V A.C., pluggable protective modules, 3+1 circuit (TN-S, TT), Width 72 mm
Product familyBasic devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12G / 1BK
Surcharge for Raw MaterialsNone
Metal FactorL-P-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works2 Day/Days
Net Weight (kg)0,678 Kg
Packaging Dimension76,00 x 106,00 x 78,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4001869427645
UPCNot available
Commodity Code85363090
LKZ_FDB/ CatalogIDLV10.1
Product Group5524
Group CodeP310
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2010
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-13-08-05
eClass7.127-13-08-05
eClass827-13-08-05
eClass927-13-08-05
eClass9.127-13-08-05
ETIM5EC000941
ETIM6EC000941
ETIM7EC000941
ETIM8EC000941

ETIM data

ETIM: EC000941 - Surge protection device for power supply systems

Value Unit
Number of conductors (without earthing) (EF001148) -
Max. discharge surge current (8/20) (EF012274) -kA
System configuration DC (EF009926) 0
System configuration IT (EF009927) 0
System configuration TN (EF009928) 0
System configuration TN-C (EF009929) 0
System configuration TN-C-S (EF009933) 0
System configuration TN-S (EF009930) 0
System configuration TT (EF009931) 0
System configuration other (EF009932) 0
Nominal voltage AC (EF004220) -V
Nominal voltage DC (EF004221) -V
Short-circuit breaking capacity (Isccr) (EF012627) 25.0kA
Max. continuous voltage AC (EF004198) -V
Max. continuous voltage DC (EF004777) -V
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Construction size (EF002566) 4 modular spacing
Max. PV-voltage (EF008795) -V
Max. conductor cross section solid (solid, stranded) (EF008827) 35.0mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 25.0mm²
Voltage protection level L-N (EF004236) 1.2kV
Voltage protection level N-PE (EF008796) 1.7kV
With remote signalling contact (EF000422) false
Integrated backup fuse (EF008797) false
Signalling at the device (EF004241) None
Category type 2 (EF004230) true
Degree of protection (IP) (EF005474) IP20
Nominal discharge surge current (8/20) (EF004214) -kA
Voltage protection level (EF003525) -kV



Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.