circuit breaker 3VA5 UL frame 250 breaking capacity class C 100kA @ 480V 3-pole, line protection TM210, FTFM, In=250A overload protection Ir=250A fixed short-circuit protection Ii=10 x In without connection

Automatic switch. 3VA5 UL Size 250 Cutting power class C 100KA @ 480 V 3 poles, prot. distributions TM210, FTFM, In=250A Overload protection Ir=250A , fixed adjustment Prot. short circuit Ii=10xIn without connection. Manufactured to order. Non-Cancelable Non-Returnable.

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Moulded Case Circuit Breakers 3VA SENTRON

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $1,194.11
Unit price: $1,194.11

Quantity Price
1+$1,194.11
2+$1,194.11
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Technical data

circuit breaker 3VA5 UL frame 250 breaking capacity class C 100kA @ 480V 3-pole, line protection TM210, FTFM, In=250A overload protection Ir=250A fixed short-circuit protection Ii=10 x In without connection
Model
product brand nameSENTRON
product designationMolded-case circuit breaker
product designation / according to UL fileCFAS
Product versionSystem protection
design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type)Yes
design of the load switch / according to UL 489 / High-Intensity-Discharge circuit breaker (HID Type)No
design of the load switch / according to UL 489 / Switching Duty circuit breaker (SWD Type)No
design of the overcurrent releaseTM210
protection function of the overcurrent releaseLI
number of poles3
General technical data
rated insulation voltage Ui800 V
Max. rated operational voltage Ue with DC750 V
power loss [W] / maximum58 W
Active power loss / for rated value of the current / at AC / in hot operating state / per pole19.33 W
mechanical service life (switching cycles) / typical20 000
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz8 000
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz4 000
electrical endurance (switching cycles) / at 480 V8 000
electrical endurance (switching cycles) / at 600 V4 000
Neutral conductors / upgradeable/retrofittableNo
product function
● communication functionNo
● other measurement functionNo
Net Weight2 kg
Current
marking / according to UL 489 / 100%-rated breakerNo
operational current
● at 40 °C250 A
● at 45 °C244 A
● at 50 °C239 A
● at 55 °C233 A
● at 60 °C227 A
● at 65 °C222 A
● at 70 °C216 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breakerC
breaking capacity maximum short-circuit current (Icu)
● at 240 V200 kA
● at 415 V110 kA
● at 690 V10 kA
breaking capacity operating short-circuit current (Ics)
● at 240 V200 kA
● at 415 V110 kA
● at 690 V10 kA
short-circuit current making capacity (Icm)
● at 240 V440 kA
● at 415 V242 kA
● at 690 V17 kA
design of short-circuit protectionFor switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter
Switching capacity according to UL 489
breaking capacity current
● at 240 V200 kA
● at 480 V100 kA
● at 600 V35 kA
Adjustable parameters
Adjustable response value current / lg min.250 A
Adjustable response value current / lg min.250 A
Ground fault protection / tripping switchable / I2t=ON/OFFNo
Mechanical Design
height [in]7.28 in
Height185 mm
width [in]4.13 in
Width105 mm
depth [in]3.27 in
depth83 mm
Connections
arrangement of electrical connectors / for main current circuitWithout connection
type of electrical connection / for main current circuitWithout
Auxiliary circuit
product component
● undervoltage releaseNo
● voltage triggerNo
● trip indicatorNo
number of CO contacts / for auxiliary contacts0
Accessories
product extension / optional / motor driveYes
Environmental conditions
protection class IP / on the frontIP40
ambient temperature
● during operation / minimum-25 °C
● during operation / maximum70 °C
● during storage / minimum-40 °C
● during storage / maximum80 °C
Certificates
reference code / according to IEC 81346-2Q
certificate of suitability / as approval for NAVAL (no combat vessels) / supplement SBNo

Downloads and manuals

General Product Approval

CSA

Confirmation

UL

Miscellaneous

VDE

Miscellaneous

General Product ApprovalEMCDeclaration of ConformityMarine / Shipping

EAC

RCM

UK Declaration of Conformity

EC/EU-Declaration of Conformity

ABS (American Bureau of Shipping)

RMRS / Russian Maritime Register

other

Miscellaneous

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
last modified:10/21/2021
Date
5/9/2022


Additional data

Product
Article Number (Market Facing Number)3VA5225-7ED31-0AA0
Product Descriptioncircuit breaker 3VA5 UL frame 250 breaking capacity class C 100kA @ 480V 3-pole, line protection TM210, FTFM, In=250A overload protection Ir=250A fixed short-circuit protection Ii=10 x In without connection
Product family3VA Molded Case Circuit Breakers up to 1000 A, UL / IEC
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12P / 1CB
Surcharge for Raw MaterialsNone
Metal FactorLOA-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works40 Day/Days
Net Weight (kg)2,000 Kg
Packaging Dimension150,00 x 245,00 x 160,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4042948864760
UPC804766317972
Commodity Code85362090
LKZ_FDB/ CatalogIDLV10
Product Group5385
Group CodeP360
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 01.01.2016
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-04-09
eClass7.127-37-04-09
eClass827-37-04-09
eClass927-37-04-09
eClass9.127-37-04-09
ETIM5EC000228
ETIM6EC000228
ETIM7EC000228
ETIM8EC000228
IDEA44850
UNSPSC1539-12-16-01

ETIM data

ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection

Value Unit
Rated permanent current Iu (EF001389) 250.0A
Rated voltage (EF003977) ['690', '690']V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 110.0kA
Overload release current setting (EF002336) ['-', '-']A
Adjustment range short-term delayed short-circuit release (EF007129) ['-', '-']A
Adjustment range undelayed short-circuit release (EF007131) ['-', '-']A
Integrated earth fault protection (EF007296) false
Type of electrical connection of main circuit (EF006819) Other
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting (EF007250) true
DIN rail (top hat rail) mounting optional (EF008904) true
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) -
With under voltage release (EF007518) -
Number of poles (EF001391) 3
Position of connection for main current circuit (EF006671) Other
Type of control element (EF006976) Rocker lever
Complete device with protection unit (EF008906) true
Motor drive integrated (EF006697) false
Motor drive optional (EF007386) true
Degree of protection (IP) (EF005474) IP40


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.