SIEMENS

Circuit breaker 3VA1 IEC Frame 100 Switching capacity class B Icu=16 kA @ 415 V 4-pole, system protection TM210, FTFM, In=100 A Overload protection Ir=100 A non-adjustable short-circuit protection Ii = 10 x In N-conductor unprotected Terminal connection

AUTOMATIC SWITCH 3VA1 IEC SIZE 100 CUTTING POWER CLASS B ICU=16KA @ 415 V 4 POLES, PROTEC. TM210, FTFM, IN=100A OVERLOAD PROTECTION IR=100A FIXED ADJUSTMENT SHORT CIRCUIT PROTECTION II=10 X IN NEUTRAL UNPROTECTED TERMINAL CONNECTION. Manufactured to order. Non-Cancelable Non-Returnable.

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Moulded Case Circuit Breakers 3VA SENTRON

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $475.14
Unit price: $475.14
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

Circuit breaker 3VA1 IEC Frame 100 Switching capacity class B Icu=16 kA @ 415 V 4-pole, system protection TM210, FTFM, In=100 A Overload protection Ir=100 A non-adjustable short-circuit protection Ii = 10 x In N-conductor unprotected Terminal connection
Model
product brand nameSENTRON
product designationMolded case circuit breaker
Product versionLine protection
design of the overcurrent releaseTM210
protection function of the overcurrent releaseLI
number of poles4
General technical data
rated insulation voltage Ui800 V
Max. rated operational voltage Ue with DC600 V
power loss [W] / maximum25 W
Active power loss / for rated value of the current / at AC / in hot operating state / per pole8.33 W
mechanical service life (switching cycles) / typical20 000
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz9 000
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz6 300
Neutral conductors / upgradeable/retrofittableNo
ground-fault monitoring versionWithout
product function
● communication functionNo
● other measurement functionNo
Net Weight1.272 kg
Current
Max. rated operational current of the frame size100 A
Courant permanent assigné Iu100 A
operational current
● at 40 °C100 A
● at 45 °C100 A
● at 50 °C100 A
● at 55 °C98 A
● at 60 °C96 A
● at 65 °C94 A
● at 70 °C91 A
Switching capacity according to IEC 60947
switching capacity class of the circuit breakerB
breaking capacity maximum short-circuit current (Icu)
● at 240 V25 kA
● at 415 V16 kA
● at 440 V8 kA
● at 500 V5 kA
● at 690 V5 kA
breaking capacity operating short-circuit current (Ics)
● at 240 V25 kA
● at 415 V16 kA
● at 440 V8 kA
● at 500 V5 kA
● at 690 V5 kA
short-circuit current making capacity (Icm)
● at 240 V52.5 kA
● at 415 V32 kA
● at 440 V13.6 kA
● at 500 V7.5 kA
● at 690 V7.5 kA
design of short-circuit protectionFor switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter
Adjustable parameters
design of the N-conductor protectionWithout
Ground fault protection / tripping switchable / I2t=ON/OFFNo
Mechanical Design
height [in]5.12 in
Height130 mm
width [in]4 in
Width101.6 mm
depth [in]2.76 in
depth70 mm
Connections
arrangement of electrical connectors / for main current circuitFront terminal
type of electrical connection / for main current circuitbox terminal on both sides
Type of connectable conductor cross-section, round conductor terminal, stranded1 x (1.5 - 70 mm²)
design of the surface / of the connections / on the top of the switch (N, 1, 3, 5)Silver
design of the surface / of the connections / on the bottom of the switch (N, 2, 4, 6)Tin
Auxiliary circuit
number of CO contacts / for auxiliary contacts0
Accessories
product extension / optional / motor driveNo
Environmental conditions
protection class IP / on the frontIP40
ambient temperature
● during operation / minimum-25 °C
● during operation / maximum70 °C
● during storage / minimum-40 °C
● during storage / maximum80 °C
Certificates
reference code / according to IEC 81346-2Q

Downloads and manuals

General Product ApprovalEMC

CCC

Confirmation

VDE

Miscellaneous

EAC

RCM

Declaration of ConformityTest CertificatesMarine / Shipping

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Miscellaneous

Special Test Certificate

Type Test Certificates/Test Report

ABS (American Bureau of Shipping)

Marine / Shippingother

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

RMRS / Russian Maritime Register

CCS / China Classification Society

Miscellaneous

other

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
last modified:10/2/2021
Date
5/11/2022


Additional data

Product
Article Number (Market Facing Number)3VA1010-2ED46-0AA0
Product DescriptionCircuit breaker 3VA1 IEC Frame 100 Switching capacity class B Icu=16 kA @ 415 V 4-pole, system protection TM210, FTFM, In=100 A Overload protection Ir=100 A non-adjustable short-circuit protection Ii = 10 x In N-conductor unprotected Terminal connection
Product family3VA Molded Case Circuit Breakers up to 1600 A, IEC
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12P / 1CB
Surcharge for Raw MaterialsNone
Metal FactorLOA-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works5 Day/Days
Net Weight (kg)1,272 Kg
Packaging Dimension119,00 x 150,00 x 116,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4042948820254
UPC804766431869
Commodity Code85362090
LKZ_FDB/ CatalogIDLV10.1
Product Group5375
Group CodeP360
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 01.04.2014
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-04-09
eClass7.127-37-04-09
eClass827-37-04-09
eClass927-37-04-09
eClass9.127-37-04-09
ETIM5EC000228
ETIM6EC000228
ETIM7EC000228
ETIM8EC000228
IDEA44850
UNSPSC1539-12-16-01

ETIM data

ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection

Value Unit
Rated permanent current Iu (EF001389) 100.0A
Rated voltage (EF003977) ['690', '690']V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 16.0kA
Overload release current setting (EF002336) ['100', '100']A
Adjustment range short-term delayed short-circuit release (EF007129) ['-', '-']A
Adjustment range undelayed short-circuit release (EF007131) ['1000', '1000']A
Integrated earth fault protection (EF007296) -
Type of electrical connection of main circuit (EF006819) Frame clamp
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting (EF007250) true
DIN rail (top hat rail) mounting optional (EF008904) true
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) -
With under voltage release (EF007518) -
Number of poles (EF001391) 4
Position of connection for main current circuit (EF006671) Front side
Type of control element (EF006976) Rocker lever
Complete device with protection unit (EF008906) true
Motor drive integrated (EF006697) false
Motor drive optional (EF007386) false
Degree of protection (IP) (EF005474) IP40



Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.