3RW3016-2BB04 SIEMENS SIRIUS soft starter S00 9 A, 4 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Spring-type te.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RW3016-2BB04 SIEMENS SIRIUS soft starter S00 9 A, 4 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Spring-type te..

3RW3016-2BB04

SIEMENS

SIRIUS soft starter S00 9 A, 4 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Spring-type terminals

More details


CONTROL AND CONTACTORS > SIRIUS soft starter

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $287.87
Unit price: $287.87

Quantity Price
1+$287.87
2+$262.72
3+$256.71
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Technical data

SIRIUS soft starter S00 9 A, 4 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Spring-type terminals
General technical data
product brand nameSIRIUS
product feature
● integrated bypass contact systemYes
● thyristorsYes
product function
● intrinsic device protectionNo
● motor overload protectionNo
● evaluation of thermistor motor protectionNo
● external resetNo
● adjustable current limitationNo
● inside-delta circuitNo
product component motor brake outputNo
insulation voltage rated valueV600
degree of pollution3, acc. to IEC 60947-4-2
reference code according to EN 61346-2Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750G
Power Electronics
product designationSoft starter
operational current
● at 40 °C rated valueA9
● at 50 °C rated valueA8
● at 60 °C rated valueA7
yielded mechanical performance for 3-phase motors
● at 230 V
— at standard circuit at 40 °C rated valuekW2.2
● at 400 V
— at standard circuit at 40 °C rated valuekW4
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated valuehp2
operating frequency rated valueHz50 ... 60
relative negative tolerance of the operating frequency%-10
relative positive tolerance of the operating frequency%10
operating voltage at standard circuit rated valueV200 ... 480
relative negative tolerance of the operating voltage at standard circuit%-15
relative positive tolerance of the operating voltage at standard circuit%10
minimum load [%]%10
continuous operating current [% of Ie] at 40 °C%115
power loss [W] at operational current at 40 °C during operation typicalW1
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage frequency 1 rated valueHz50
control supply voltage frequency 2 rated valueHz60
relative negative tolerance of the control supply voltage frequency%-10
relative positive tolerance of the control supply voltage frequency%10
control supply voltage 1 at AC
● at 50 Hz rated valueV24
● at 60 Hz rated valueV24
relative negative tolerance of the control supply voltage at AC at 50 Hz%-20
relative positive tolerance of the control supply voltage at AC at 50 Hz%20
relative negative tolerance of the control supply voltage at AC at 60 Hz%-20
relative positive tolerance of the control supply voltage at AC at 60 Hz%20
control supply voltage 1 at DC rated valueV24
relative negative tolerance of the control supply voltage at DC%-20
relative positive tolerance of the control supply voltage at DC%20
display version for fault signalred
Mechanical data
size of engine control deviceS00
widthmm45
heightmm120
depthmm150
fastening methodscrew and snap-on mounting
mounting positionWith vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back
required spacing with side-by-side mounting
● upwardsmm60
● at the sidemm15
● downwardsmm40
wire length maximumm300
number of poles for main current circuit3
Connections/ Terminals
type of electrical connection
● for main current circuitspring-loaded terminals
● for auxiliary and control circuitspring-loaded terminals
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts1
number of CO contacts for auxiliary contacts0
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point
● solid2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
● finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
type of connectable conductor cross-sections at AWG cables for main contacts for box terminal
● using the front clamping point2x (16 ... 10)
type of connectable conductor cross-sections for main contacts
● solid1 ... 4 mm²
● finely stranded with core end processing1 ... 2.5 mm²
type of connectable conductor cross-sections for auxiliary contacts
● solid2x (0.25 ... 2.5 mm²)
● finely stranded with core end processing2x (0.25 ... 1.5 mm²)
type of connectable conductor cross-sections at AWG cables
● for main contacts16 ... 12
● for auxiliary contacts2x (24 ... 14)
Ambient conditions
installation altitude at height above sea levelm5 000
environmental category
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● during operation according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
ambient temperature
● during operation°C-25 ... +60
● during storage°C-40 ... +80
derating temperature°C40
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Certificates/ approvals
General Product ApprovalEMC

CSA

CCC

Confirmation

UL

EAC

RCM

Declaration of ConformityTest Certificatesother

EC/EU-Declaration of Conformity

Type Test Certificates/Test Report

Confirmation

Miscellaneous

UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor
● at 220/230 V
— at standard circuit at 50 °C rated valuehp2
● at 460/480 V
— at standard circuit at 50 °C rated valuehp5

Downloads and manuals

contact rating of auxiliary contacts according to ULB300 / R300
Further information
Simulation Tool for Soft Starters (STS)
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:1/16/2022
Date
5/4/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RW3016-2BB04
Product DescriptionSIRIUS soft starter S00 9 A, 4 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Spring-type terminals
Product family3RW30 soft starters
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group42G / 42G
Surcharge for Raw MaterialsNone
Metal FactorLBO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works50 Day/Days
Net Weight (kg)0,474 Kg
Packaging Dimension217,00 x 164,00 x 60,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209719699
UPC754554958194
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group5345
Group CodeR711
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead titanium zirconium oxide

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-09-07
eClass7.127-37-09-07
eClass827-37-09-07
eClass927-37-09-07
eClass9.127-37-09-07
ETIM5EC000640
ETIM6EC000640
ETIM7EC000640
ETIM8EC000640
IDEA44740
UNSPSC1439-12-15-21
UNSPSC1539-12-15-21

ETIM data

ETIM: EC000640 - Soft starter

Value Unit
Release class (EF006668) -
Degree of protection (NEMA) (EF011959) -
With display (EF000458) -
Internal bypass (EF009214) -
Torque control (EF009215) -
Rated operation current Ie at 40 °C Tu (EF007039) 9A
Rated operating voltage Ue (EF002418) ['200', '480']V
Rated power three-phase motor, inline, at 230 V (EF007053) 2.2kW
Rated power three-phase motor, inline, at 400 V (EF007054) 4.0kW
Function (EF000030) Single direction
Rated surrounding temperature without derating (EF007074) 40°C
Rated control supply voltage Us at AC 50HZ (EF003978) ['-', '24']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['-', '24']V
Rated control supply voltage Us at DC (EF003980) ['-', '24']V
Voltage type for actuating (EF008242) AC/DC
Integrated motor overload protection (EF007297) false
Degree of protection (IP) (EF005474) IP20
Rated power three-phase motor, inside delta, at 230 V (EF007055) -kW
Rated power three-phase motor, inside delta, at 400 V (EF007056) -kW


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.