Circuit breaker size S3 for motor protection, CLASS 10 A-release 80...100 A N-release 1300 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC

More details


CONTROL AND CONTACTORS > Motor protection switches

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $380.62
Unit price: $380.62

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

More info



Technical data

Circuit breaker size S3 for motor protection, CLASS 10 A-release 80...100 A N-release 1300 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC
product brand nameSIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV2
General technical data
size of the circuit-breakerS3
size of contactor can be combined company-specificS3
product extension auxiliary switchYes
power loss [W] for rated value of the current
● at AC in hot operating state44 W
● at AC in hot operating state per pole14.7 W
insulation voltage with degree of pollution 3 at AC rated value1 000 V
surge voltage resistance rated value8 kV
maximum permissible voltage for safe isolation in networks with grounded star point
● between main and auxiliary circuit400 V
● between main and auxiliary circuit400 V
shock resistance according to IEC 60068-2-2725g / 11 ms Sinus
mechanical service life (switching cycles)
● of the main contacts typical25 000
● of auxiliary contacts typical25 000
electrical endurance (switching cycles) typical25 000
type of protection according to ATEX directive 2014/34/EUEx II (2) GD
certificate of suitability according to ATEX directive 2014/34/EUDMT 02 ATEX F 001
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)03/01/2017
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-20 ... +60 °C
● during storage-50 ... +80 °C
● during transport-50 ... +80 °C
temperature compensation-20 ... +60 °C
relative humidity during operation10 ... 95 %
Main circuit
number of poles for main current circuit3
adjustable current response value current of the current-dependent overload release80 ... 100 A
operating voltage
● rated value690 V
● rated value20 ... 690 V
● at AC-3 rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current rated value100 A
operational current
● at AC-3 at 400 V rated value100 A
operating power
● at AC-3
— at 230 V rated value30 kW
— at 400 V rated value45 kW
— at 500 V rated value55 kW
— at 690 V rated value90 kW
operating frequency
● at AC-3 maximum15 1/h
Auxiliary circuit
design of the auxiliary switchtransverse
number of NC contacts for auxiliary contacts1
● note1
number of NO contacts for auxiliary contacts1
● note1
operational current of auxiliary contacts at AC-15
● at 24 V2 A
● at 230 V0.5 A
operational current of auxiliary contacts at DC-13
● at 24 V1 A
● at 60 V0.15 A
Protective and monitoring functions
product function
● ground fault detectionNo
● phase failure detectionYes
trip classCLASS 10
design of the overload releasethermal
breaking capacity operating short-circuit current (Ics) at AC
● at 240 V rated value100 kA
● at 400 V rated value30 kA
● at 500 V rated value4 kA
● at 690 V rated value3 kA
breaking capacity maximum short-circuit current (Icu)
● at AC at 240 V rated value100 kA
● at AC at 400 V rated value65 kA
● at AC at 500 V rated value8 kA
● at AC at 690 V rated value5 kA
response value current of instantaneous short-circuit trip unit1 300 A
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value100 A
● at 600 V rated value100 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value7.5 hp
— at 230 V rated value20 hp
● for 3-phase AC motor
— at 200/208 V rated value30 hp
— at 220/230 V rated value40 hp
— at 460/480 V rated value75 hp
— at 575/600 V rated value100 hp
contact rating of auxiliary contacts according to ULC300 / R300
Short-circuit protection
product function short circuit protectionYes
design of the short-circuit tripmagnetic
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
height165 mm
width70 mm
depth176 mm
required spacing
● for grounded parts at 400 V
— downwards70 mm
— upwards70 mm
— at the side10 mm
● for live parts at 400 V
— downwards70 mm
— upwards70 mm
— at the side10 mm
● for grounded parts at 500 V
— downwards110 mm
— upwards110 mm
— at the side10 mm
● for live parts at 500 V
— downwards110 mm
— upwards110 mm
— at the side10 mm
● for grounded parts at 690 V
— downwards150 mm
— upwards150 mm
— at the side30 mm
● for live parts at 690 V
— downwards150 mm
— upwards150 mm
— at the side30 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitNo
type of electrical connection
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
arrangement of electrical connectors for main current circuitTop and bottom
type of connectable conductor cross-sections
● for main contacts
— solid2x (2.5 ... 16 mm²)
— solid or stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
— finely stranded with core end processing2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
— finely stranded without core end processing2x (10 ... 35 mm²), 1x (10 ... 50 mm²)
type of connectable conductor cross-sections
● for auxiliary contacts
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
tightening torque
● for main contacts for ring cable lug4.5 ... 6 N·m
outer diameter of the usable ring cable lug maximum19 mm
tightening torque
● for main contacts with screw-type terminals4.5 ... 6 N·m
● for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
design of the thread of the connection screw
● of the auxiliary and control contactsM3
Safety related data
B10 value
● with high demand rate according to SN 319205 000
proportion of dangerous failures
● with low demand rate according to SN 3192050 %
● with high demand rate according to SN 3192050 %
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
display version for switching statusHandle
Certificates/ approvals

Downloads and manuals

General Product Approval

CSA

CCC

Confirmation

UL

KC

EAC

For use in hazardous locationsDeclaration of ConformityTest Certificates

ATEX-EC-Type-Examination-Certificate

IECEx

EC/EU-Declaration of Conformity

UK Declaration of Conformity

Type Test Certificates/Test Report

Special Test Certificate

Marine / Shipping

ABS (American Bureau of Shipping)

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

PRS / Polski Rejestr Statkow

RINA / Registro Italiano Navale

Marine / ShippingotherRailway

RMRS / Russian Maritime Register

Confirmation

Household and similar appliances

Vibration and Shock

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:12/14/2021
Date
5/3/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RV2041-4MA15
Product DescriptionCircuit breaker size S3 for motor protection, CLASS 10 A-release 80...100 A N-release 1300 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC
Product familySIRIUS 3RV2 motor starter protectors
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41E / 41E
Surcharge for Raw MaterialsNone
Metal FactorLDP-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works40 Day/Days
Net Weight (kg)2,292 Kg
Packaging Dimension103,00 x 195,00 x 172,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047621013985
UPC804766472718
Commodity Code85362090
LKZ_FDB/ CatalogIDCC-IC10
Product Group3673
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.03.2017
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-04-01
eClass7.127-37-04-01
eClass827-37-04-01
eClass927-37-04-01
eClass9.127-37-04-01
ETIM5EC000074
ETIM6EC000074
ETIM7EC000074
ETIM8EC000074
IDEA44845
UNSPSC1539-12-16-01

ETIM data

ETIM: EC000074 - Motor protection circuit-breaker

Value Unit
Overload release current setting (EF002336) ['80', '100']A
Adjustment range undelayed short-circuit release (EF007131) ['1300', '1300']A
With thermal protection (EF006233) thermal
Phase failure sensitive (EF007400) true
Switch off technique (EF007007) Magnetic
Rated operating voltage (EF001435) ['690', '690']V
Rated permanent current Iu (EF001389) 100.0A
Rated operation power at AC-3, 230 V (EF007025) 30.0kW
Rated operation power at AC-3, 400 V (EF001364) 45.0kW
Type of electrical connection of main circuit (EF006819) Screw connection
Type of control element (EF006976) Turn button
Device construction (EF008240) Built-in device fixed built-in technique
With integrated auxiliary switch (EF001387) true
With integrated under voltage release (EF001390) false
Number of poles (EF001391) 3
Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049) 65.0kA
Degree of protection (IP) (EF005474) IP20
Height (EF000040) 165.0mm
Width (EF000008) 70.0mm
Depth (EF000049) 176.0mm


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.