3RU2116-1HB0 SIEMENS Overload relay 5.5...8.0 A Thermal For motor protection Size S00, Class 10 Contactor mo.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RU2116-1HB0 SIEMENS Overload relay 5.5...8.0 A Thermal For motor protection Size S00, Class 10 Contactor mo..

3RU2116-1HB0

SIEMENS

Overload relay 5.5...8.0 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset

More details


Low-voltage industrial components > Thermal overload relay

CONTROL AND CONTACTORS > Thermal relays

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $79.21
Unit price: $79.21

Quantity Price
1+$79.21
2+$72.03
3+$66.52
4+$63.39
6+$60.73
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC000106 - Thermal overload relay

Value Unit
Reset function automatic (EF011941) -
Mounting method (EF000003) -
Reset function input (EF011940) -
Reset function push-button (EF011942) -
Adjustable current range (EF008211) ['5.5', '8']A
Max. rated operation voltage Ue (EF007357) 690V
Type of electrical connection of main circuit (EF006819) Screw connection
Number of auxiliary contacts as normally closed contact (EF001377) 1
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as change-over contact (EF003531) 0
Release class (EF006668) CLASS 10


Overload relay 5.5...8.0 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset
product brand nameSIRIUS
Product designationthermal overload relay
Product type designation3RU2
General technical data
Size of overload relayS00
Size of contactor can be combined company-specificS00
Power loss [W] for rated value of the current
● at AC in hot operating state6.6 W
● at AC in hot operating state per pole2.2 W
Insulation voltage with degree of pollution 3 at AC rated value690 V
Surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation
● in networks with grounded star point between auxiliary and auxiliary circuit440 V
● in networks with grounded star point between auxiliary and auxiliary circuit440 V
● in networks with grounded star point between main and auxiliary circuit440 V
● in networks with grounded star point between main and auxiliary circuit440 V
● protection class IP on the frontIP20
● Protection class IP of the terminalIP20
Shock resistance
● acc. to IEC 60068-2-278g / 11 ms
Type of protection according to ATEX directive 2014/34/EUEx II (2) GD
Certificate of suitability according to ATEX directive 2014/34/EUDMT 98 ATEX G 001
Reference code acc. to DIN EN 81346-2F
Ambient conditions
Installation altitude at height above sea level
● maximum2 000 m
Ambient temperature
● during operation-40 ... +70 °C
● during storage-55 ... +80 °C
● during transport-55 ... +80 °C
Temperature compensation-40 ... +60 °C
Relative humidity during operation10 ... 95 %
Main circuit
Number of poles for main current circuit3
adjustable pick-up value current of the current-dependent overload release5.5 ... 8 A
Operating voltage
● rated value690 V
● at AC-3 rated value maximum690 V
Operating frequency rated value50 ... 60 Hz
Operating current rated value8 A
Operating power at AC-3
● at 400 V rated value3 kW
● at 500 V rated value4 kW
● at 690 V rated value5.5 kW
Auxiliary circuit
Design of the auxiliary switchintegrated
Number of NC contacts for auxiliary contacts1
● Notefor contactor disconnection
Number of NO contacts for auxiliary contacts1
● Notefor message "Tripped"
Number of CO contacts
● for auxiliary contacts0
● operating current of auxiliary contacts at AC-15 at 24 V3 A
● Operating current of auxiliary contacts at AC-15 at 110 V3 A
● Operating current of auxiliary contacts at AC-15 at 120 V3 A
● Operating current of auxiliary contacts at AC-15 at 125 V3 A
● Operating current of auxiliary contacts at AC-15 at 230 V2 A
● operating current of auxiliary contacts at AC-15 at 400 V1 A
● operating current of auxiliary contacts at DC-13 at 24 V2 A
● Operating current of auxiliary contacts at DC-13 at 60 V0.3 A
● Operating current of auxiliary contacts at DC-13 at 110 V0.22 A
● operating current of auxiliary contacts at DC-13 at 125 V0.22 A
● Operating current of auxiliary contacts at DC-13 at 220 V0.11 A
Contact rating of auxiliary contacts according to ULB600 / R300
Protective and monitoring functions
Trip classCLASS 10
Design of the overload releasethermal
UL/CSA ratings
Full-load current (FLA) for three-phase AC motor
● at 480 V rated value8 A
● at 600 V rated value8 A
Short-circuit protection
Design of the fuse link
● for short-circuit protection of the auxiliary switch requiredfuse gG: 6 A, quick: 10 A
Installation/ mounting/ dimensions
● mounting positionany
Mounting typeContactor mounting
Height76 mm
Width45 mm
Depth70 mm
Connections/ Terminals
Product function
● removable terminal for auxiliary and control circuitNo
● Type of electrical connection for main current circuitscrew-type terminals
● Type of electrical connection for auxiliary and control current circuitscrew-type terminals
Arrangement of electrical connectors for main current circuitTop and bottom
Type of connectable conductor cross-sections
● for main contacts
— single or multi-stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Type of connectable conductor cross-sections
● for auxiliary contacts
— single or multi-stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
Tightening torque
● for main contacts with screw-type terminals0.8 ... 1.2 N·m
● for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
Design of screwdriver shaftDiameter 5 ... 6 mm
Size of the screwdriver tipPozidriv PZ 2
Design of the thread of the connection screw
● for main contactsM3
● of the auxiliary and control contactsM3
Safety related data
Failure rate [FIT]
● with low demand rate acc. to SN 3192050 FIT
MTTF with high demand rate2 280 y
T1 value for proof test interval or service life acc. to IEC 6150820 y
Display
Display version
● for switching statusSlide switch
Certificates/ approvals
General Product ApprovalFor use in hazardous locations

CCC

CSA

UL

EAC

ATEX-EC-Type-Examination-Certificate

IECEx

Declaration of ConformityTest CertificatesMarine / Shipping

EC/EU-Declaration of Conformity

Miscellaneous

Type Test Certificates/Test Report

Special Test Certificate

ABS (American Bureau of Shipping)

BV / Bureau Veritas

Marine / Shippingother

LR (Lloyds Register)

PRS / Polski Rejestr Statkow

RINA / Registro Italiano Navale

RMRS / Russian Maritime Register

DNV-GL

Confirmation

Railway

Vibration and Shock

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:08/19/2020


Product
Article Number (Market Facing Number)3RU2116-1HB0
Product DescriptionOverload relay 5.5...8.0 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset
Product family3RU2 for standard applications
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group41F
Surcharge for Raw MaterialsNone
Metal FactorL-O-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works1 Day/Days
Net Weight (kg)0,159 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension49,00 x 102,00 x 84,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209781665
UPC662643920444
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5346
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-15-01
eClass7.127-37-15-01
eClass827-37-15-01
eClass927-37-15-01
eClass9.127-37-15-01
ETIM4EC000106
ETIM5EC000106
ETIM6EC000106
ETIM7EC000106
IDEA45366
UNSPSC1439-12-15-21
UNSPSC1539-12-23-30

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.