| product brand name | SIRIUS | |
| Product designation | thermal overload relay | |
| General technical data: | ||
| Size of overload relay | S3 | |
| Size of contactor can be combined company-specific | S3 | |
| Power loss [W] total typical | 16.5 W | |
| Insulation voltage with degree of pollution 3 rated value | 1 000 V | |
| Surge voltage resistance rated value | 8 kV | |
| Protection class IP | ||
| ● on the front | IP20 | |
| Shock resistance | 8g / 10 ms | |
| Type of protection | DMT 98 ATEX G 001 | |
| Protection against electrical shock | finger-safe | |
| Equipment marking acc. to DIN EN 81346-2 | F | |
| Ambient conditions: | ||
| Installation altitude at height above sea level maximum | 2 000 m | |
| Ambient temperature | ||
| ● during operation | -20 ... +70 °C | |
| ● during storage | -55 ... +80 °C | |
| ● during transport | -55 ... +80 °C | |
| Relative humidity during operation | 100 % | |
| Main circuit: | ||
| Number of poles for main current circuit | 3 | |
| Adjustable pick-up value current of the current-dependent overload release | 70 ... 90 A | |
| Operating voltage | ||
| ● at AC-3 rated value maximum | 1 000 V | |
| Auxiliary circuit: | ||
| Number of NC contacts | ||
| ● for auxiliary contacts | 1 | |
| Number of NO contacts | ||
| ● for auxiliary contacts | 1 | |
| Number of CO contacts | ||
| ● for auxiliary contacts | 0 | |
| Operating current of auxiliary contacts at AC-15 | ||
| ● at 24 V | 3 A | |
| ● at 110 V | 3 A | |
| ● at 120 V | 3 A | |
| ● at 125 V | 3 A | |
| ● at 230 V | 2 A | |
| ● at 400 V | 1 A | |
| Operating current of auxiliary contacts at DC-13 | ||
| ● at 24 V | 1 A | |
| ● at 110 V | 0.22 A | |
| ● at 125 V | 0.22 A | |
| ● at 220 V | 0.11 A | |
| Protective and monitoring functions: | ||
| Trip class | CLASS 10 | |
| Short-circuit protection | ||
| Design of the fuse link | ||
| ● for short-circuit protection of the main circuit | ||
| — with type of coordination 1 required | gG: 250 A | |
| — with type of assignment 2 required | gG: 160 A | |
| ● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 6 A, quick: 10 A | |
| Installation/ mounting/ dimensions: | ||
| Mounting position | with vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back | |
| Mounting type | stand-alone installation | |
| Height | 120 mm | |
| Width | 70 mm | |
| Depth | 140 mm | |
| Required spacing | ||
| ● with side-by-side mounting | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — downwards | 0 mm | |
| — at the side | 0 mm | |
| ● for grounded parts | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — at the side | 6 mm | |
| — downwards | 0 mm | |
| ● for live parts | ||
| — forwards | 0 mm | |
| — Backwards | 0 mm | |
| — upwards | 0 mm | |
| — downwards | 0 mm | |
| — at the side | 6 mm | |
| Connections/Terminals: | ||
| Product function | ||
| ● removable terminal for auxiliary and control circuit | No | |
| Type of electrical connection | ||
| ● for main current circuit | screw-type terminals | |
| ● for auxiliary and control current circuit | Cage Clamp terminals | |
| Type of connectable conductor cross-sections | ||
| ● for main contacts | ||
| — solid | 2x (2.5 ... 16 mm²) | |
| — stranded | 2x (10 ... 50 mm²), 10 ... 70 mm² | |
| — finely stranded with core end processing | 2x (2.5 ... 35 mm²), 2.5 ... 50 mm² | |
| ● at AWG conductors for main contacts | 2x (10 ... 1/0), 1x (10 ... 2/0) | |
| Type of connectable conductor cross-sections | ||
| ● for auxiliary contacts | ||
| — solid | 2x (0.5 ... 2.5 mm²) | |
| — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) | |
| — finely stranded without core end processing | 2x (0.5 ... 1.5 mm²) | |
| ● at AWG conductors for auxiliary contacts | 2x (20 ... 14) | |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 3RU1146-4LD1 SIEMENS OVERLOAD RELAY, 70...90 A, 1NO+1NC, SIZE S3, MAIN CUR.: SCREW CONNECTION AUX. CUR..: | 74 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.