3RT2015-4AN61 SIEMENS Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 200 V AC, 50 Hz 200-220 V, 60 Hz, 3-pole.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RT2015-4AN61 SIEMENS Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 200 V AC, 50 Hz 200-220 V, 60 Hz, 3-pole..

3RT2015-4AN61

SIEMENS

Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 200 V AC, 50 Hz 200-220 V, 60 Hz, 3-pole, Size S00, ring cable lug connection

SIRIUS Innovations Contactor, AC-3, 3KW/400V, 1NA, AC 200V 50HZ, 200...220V 60HZ, S00 ring connection. Manufactured to order. Non-Cancelable Non-Returnable.

More details


Low-voltage industrial components > Power contactor, AC switching

CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $47.08
Unit price: $47.08

Quantity Price
1+$47.08
2+$45.83
4+$39.15
5+$37.57
7+$36.10
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

More info



Technical data

Power contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 200 V AC, 50 Hz 200-220 V, 60 Hz, 3-pole, Size S00, ring cable lug connection
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS00
product extension
● function module for communicationNo
● auxiliary switchYes
power loss [W] for rated value of the current
● at AC in hot operating state1.2 W
● at AC in hot operating state per pole0.4 W
● without load current share typical4.8 W
insulation voltage
● of main circuit with degree of pollution 3 rated value690 V
● of auxiliary circuit with degree of pollution 3 rated value690 V
surge voltage resistance
● of main circuit rated value6 kV
● of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1400 V
shock resistance at rectangular impulse
● at AC6,7g / 5 ms, 4,2g / 10 ms
shock resistance with sine pulse
● at AC10,5g / 5 ms, 6,6g / 10 ms
mechanical service life (switching cycles)
● of contactor typical30 000 000
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)10/01/2009
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
operating voltage
● at AC-3 rated value maximum690 V
● at AC-3e rated value maximum690 V
operational current
● at AC-1 at 400 V at ambient temperature 40 °C rated value18 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value18 A
— up to 690 V at ambient temperature 60 °C rated value16 A
● at AC-3
— at 400 V rated value7 A
— at 500 V rated value6 A
— at 690 V rated value4.9 A
● at AC-3e
— at 400 V rated value7 A
— at 500 V rated value6 A
— at 690 V rated value4.9 A
● at AC-4 at 400 V rated value6.5 A
● at AC-5a up to 690 V rated value15.8 A
● at AC-5b up to 400 V rated value5.8 A
● at AC-6a
— up to 230 V for current peak value n=20 rated value4 A
— up to 400 V for current peak value n=20 rated value4 A
— up to 500 V for current peak value n=20 rated value3.8 A
— up to 690 V for current peak value n=20 rated value3.6 A
● at AC-6a
— up to 230 V for current peak value n=30 rated value2.7 A
— up to 400 V for current peak value n=30 rated value2.7 A
— up to 500 V for current peak value n=30 rated value2.5 A
— up to 690 V for current peak value n=30 rated value2.4 A
minimum cross-section in main circuit at maximum AC-1 rated value2.5 mm²
operational current for approx. 200000 operating cycles at AC-4
● at 400 V rated value2.6 A
● at 690 V rated value1.8 A
operational current
● at 1 current path at DC-1
— at 24 V rated value15 A
— at 110 V rated value1.5 A
— at 220 V rated value0.6 A
— at 440 V rated value0.42 A
— at 600 V rated value0.42 A
● with 2 current paths in series at DC-1
— at 24 V rated value15 A
— at 110 V rated value8.4 A
— at 220 V rated value1.2 A
— at 440 V rated value0.6 A
— at 600 V rated value0.5 A
● with 3 current paths in series at DC-1
— at 24 V rated value15 A
— at 110 V rated value15 A
— at 220 V rated value15 A
— at 440 V rated value0.9 A
— at 600 V rated value0.7 A
● at 1 current path at DC-3 at DC-5
— at 24 V rated value15 A
— at 110 V rated value0.1 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value15 A
— at 110 V rated value0.25 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value15 A
— at 110 V rated value15 A
— at 220 V rated value1.2 A
— at 440 V rated value0.14 A
— at 600 V rated value0.14 A
operating power
● at AC-3
— at 230 V rated value1.5 kW
— at 400 V rated value3 kW
— at 500 V rated value3 kW
— at 690 V rated value4 kW
● at AC-3e
— at 230 V rated value1.5 kW
— at 400 V rated value3 kW
— at 500 V rated value3 kW
— at 690 V rated value4 kW
operating power for approx. 200000 operating cycles at AC-4
● at 400 V rated value1.15 kW
● at 690 V rated value1.15 kW
operating apparent power at AC-6a
● up to 230 V for current peak value n=20 rated value1.5 kVA
● up to 400 V for current peak value n=20 rated value2.7 kVA
● up to 500 V for current peak value n=20 rated value3.3 kVA
● up to 690 V for current peak value n=20 rated value4.3 kVA
operating apparent power at AC-6a
● up to 230 V for current peak value n=30 rated value1 kVA
● up to 400 V for current peak value n=30 rated value1.8 kVA
● up to 500 V for current peak value n=30 rated value2.2 kVA
● up to 690 V for current peak value n=30 rated value2.9 kVA
short-time withstand current in cold operating state up to 40 °C
● limited to 1 s switching at zero current maximum120 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum86 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 10 s switching at zero current maximum67 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum52 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum43 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency
● at AC10 000 1/h
operating frequency
● at AC-1 maximum1 000 1/h
● at AC-2 maximum750 1/h
● at AC-3 maximum750 1/h
● at AC-3e maximum750 1/h
● at AC-4 maximum250 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
control supply voltage at AC
● at 50 Hz rated value200 V
● at 60 Hz rated value220 V
operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.85 ... 1.1
apparent pick-up power of magnet coil at AC
● at 50 Hz26.4 VA
● at 60 Hz31.7 VA
inductive power factor with closing power of the coil
● at 50 Hz0.81
● at 60 Hz0.81
apparent holding power of magnet coil at AC
● at 50 Hz4.4 VA
● at 60 Hz4.8 VA
inductive power factor with the holding power of the coil
● at 50 Hz0.24
● at 60 Hz0.25
closing delay
● at AC9 ... 35 ms
opening delay
● at AC7 ... 13 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NO contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
operational current at AC-15
● at 230 V rated value10 A
● at 400 V rated value3 A
● at 500 V rated value2 A
● at 690 V rated value1 A
operational current at DC-12
● at 24 V rated value10 A
● at 48 V rated value6 A
● at 60 V rated value6 A
● at 110 V rated value3 A
● at 125 V rated value2 A
● at 220 V rated value1 A
● at 600 V rated value0.15 A
operational current at DC-13
● at 24 V rated value10 A
● at 48 V rated value2 A
● at 60 V rated value2 A
● at 110 V rated value1 A
● at 125 V rated value0.9 A
● at 220 V rated value0.3 A
● at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value4.8 A
● at 600 V rated value6.1 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value0.25 hp
— at 230 V rated value0.75 hp
● for 3-phase AC motor
— at 200/208 V rated value1.5 hp
— at 220/230 V rated value2 hp
— at 460/480 V rated value3 hp
— at 575/600 V rated value5 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 requiredgG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
— with type of assignment 2 requiredgG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
● side-by-side mountingYes
height58 mm
width45 mm
depth73 mm
required spacing
● with side-by-side mounting
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
● for grounded parts
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
● for live parts
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
type of electrical connection
● for main current circuitRing cable lug connection
● for auxiliary and control circuitring terminal lug connection
● at contactor for auxiliary contactsRing cable lug connection
● of magnet coilRing cable lug connection
Safety related data
product function
● mirror contact according to IEC 60947-4-1Yes; with 3RH29
B10 value with high demand rate according to SN 319201 000 000
proportion of dangerous failures
● with low demand rate according to SN 3192040 %
● with high demand rate according to SN 3192073 %
failure rate [FIT] with low demand rate according to SN 31920100 FIT
protection class IP on the front according to IEC 60529IP00
suitability for use
● safety-related switching OFFYes
Certificates/ approvals

Downloads and manuals

General Product Approval

CSA

CCC

Confirmation

UL

KC

EAC

EMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest Certificates

RCM

Type Examination Certificate

EC/EU-Declaration of Conformity

UK Declaration of Conformity

Type Test Certificates/Test Report

Special Test Certificate

Marine / Shipping

ABS (American Bureau of Shipping)

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

PRS / Polski Rejestr Statkow

RINA / Registro Italiano Navale

Marine / Shippingother

RMRS / Russian Maritime Register

Confirmation

Household and similar appliances

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:2/15/2022
Date
5/13/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RT2015-4AN61
Product DescriptionPower contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 200 V AC, 50 Hz 200-220 V, 60 Hz, 3-pole, Size S00, ring cable lug connection
Product familySIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41B / 41B
Surcharge for Raw MaterialsNone
Metal FactorLDO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works60 Day/Days
Net Weight (kg)0,231 Kg
Packaging Dimension50,00 x 61,50 x 77,50
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209843370
UPC662643907520
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5330
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-10-03
eClass7.127-37-10-03
eClass827-37-10-03
eClass927-37-10-03
eClass9.127-37-10-03
ETIM5EC000066
ETIM6EC000066
ETIM7EC000066
ETIM8EC000066
IDEA44755
UNSPSC1439-12-15-21
UNSPSC1539-12-15-29

ETIM data

ETIM: EC000066 - Power contactor, AC switching

Value Unit
Rated operation power at AC-4, 400 V (EF008496) -kW
Rated control supply voltage Us at DC (EF003980) ['-', '-']V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 18A
Rated operation current Ie at AC-3, 400 V (EF001392) 7A
Rated operation power at AC-3, 400 V (EF001364) 3.0kW
Rated operation current Ie at AC-4, 400 V (EF008495) 6.5A
Rated operation power NEMA (EF011960) 2.20649625kW
Modular version (EF001126) true
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) -
Type of electrical connection of main circuit (EF006819) Other
Number of normally closed contacts as main contact (EF001375) -
Number of main contacts as normally open contact (EF001374) 3
Rated control supply voltage Us at AC 50HZ (EF003978) -V
Rated control supply voltage Us at AC 60HZ (EF003979) -V


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.