Product successfully added to your shopping cart
3RT1317-1AP00
SIEMENS
1
Contactor, AC-1, 14.5 kW / 400 V AC-1, 22 A, 230 V AC, 50/60 Hz 4-pole, 4 NO Size S00 Screw terminal !!! Phased-out product !!! Successor is SIRIUS 3RT2 Preferred successor type is >>3RT2317-1AP00<<
CONTROL AND CONTACTORS > Contactors for switching motors
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
product brand name | SIRIUS | |
Product designation | power contactor | |
General technical data: | ||
Size of contactor | S00 | |
Degree of pollution | 3 | |
Protection class IP | ||
● on the front | IP20 | |
● of the terminal | IP20 | |
Mechanical service life (switching cycles) | ||
● of contactor typical | 30 000 000 | |
● of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 | |
● of the contactor with added auxiliary switch block typical | 10 000 000 | |
Ambient conditions: | ||
Installation altitude at height above sea level maximum | 2 000 m | |
Ambient temperature | ||
● during operation | -25 ... +60 °C | |
Main circuit: | ||
Number of NO contacts for main contacts | 4 | |
Number of NC contacts for main contacts | 0 | |
Operating current | ||
● at AC-1 at 400 V | ||
— at ambient temperature 40 °C rated value | 22 A | |
● at AC-1 | ||
— up to 690 V at ambient temperature 40 °C rated value | 22 A | |
— up to 690 V at ambient temperature 60 °C rated value | 20 A | |
● at AC-3 | ||
— at 400 V rated value | 12 A | |
Operating current | ||
● at 1 current path at DC-1 | ||
— at 24 V rated value | 22 A | |
— at 110 V rated value | 2.1 A | |
● with 2 current paths in series at DC-1 | ||
— at 24 V rated value | 22 A | |
— at 110 V rated value | 12 A | |
● with 3 current paths in series at DC-1 | ||
— at 24 V rated value | 22 A | |
— at 110 V rated value | 22 A | |
Operating current | ||
● at 1 current path at DC-3 at DC-5 | ||
— at 24 V rated value | 20 A | |
— at 110 V rated value | 0.15 A | |
● with 2 current paths in series at DC-3 at DC-5 | ||
— at 110 V rated value | 0.35 A | |
— at 24 V rated value | 20 A | |
● with 3 current paths in series at DC-3 at DC-5 | ||
— at 110 V rated value | 20 A | |
— at 24 V rated value | 20 A | |
Operating power | ||
● at AC-1 | ||
— at 400 V rated value | 14.5 kW | |
● at AC-2 at 400 V rated value | 5.5 kW | |
● at AC-3 | ||
— at 400 V rated value | 5.5 kW | |
Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor | 1.24 W | |
Control circuit/ Control: | ||
Type of voltage of the control supply voltage | AC | |
Control supply voltage at AC | ||
● at 50 Hz rated value | 230 V | |
● at 60 Hz rated value | 230 V | |
Control supply voltage frequency 1 rated value | 50 Hz | |
Control supply voltage frequency 2 rated value | 60 Hz | |
Operating range factor control supply voltage rated value of magnet coil at AC | ||
● at 50 Hz | 0.8 ... 1.1 | |
● at 60 Hz | 0.85 ... 1.1 | |
Apparent pick-up power of magnet coil at AC | 27 V·A | |
Inductive power factor with closing power of the coil | 0.8 | |
Apparent holding power of magnet coil at AC | 4.4 V·A | |
Inductive power factor with the holding power of the coil | 0.27 | |
Auxiliary circuit: | ||
Number of NC contacts | ||
● for auxiliary contacts | ||
— instantaneous contact | 0 | |
Number of NO contacts | ||
● for auxiliary contacts | ||
— instantaneous contact | 0 | |
Operating current at AC-12 maximum | 10 A | |
Operating current at AC-15 | ||
● at 230 V rated value | 6 A | |
● at 400 V rated value | 3 A | |
Operating current at DC-12 | ||
● at 60 V rated value | 6 A | |
● at 110 V rated value | 3 A | |
● at 220 V rated value | 1 A | |
Operating current at DC-13 | ||
● at 24 V rated value | 10 A | |
● at 60 V rated value | 2 A | |
● at 110 V rated value | 1 A | |
● at 220 V rated value | 0.3 A | |
Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) | |
Short-circuit protection | ||
Design of the fuse link | ||
● for short-circuit protection of the main circuit | ||
— with type of coordination 1 required | fuse gL/gG: 35 A | |
— with type of assignment 2 required | fuse gL/gG: 20 A | |
● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A | |
Installation/ mounting/ dimensions: | ||
Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 | |
● Side-by-side mounting | Yes | |
Height | 57.5 mm | |
Width | 45 mm | |
Depth | 72 mm | |
Required spacing | ||
● for grounded parts | ||
— at the side | 6 mm | |
Connections/Terminals: | ||
Type of electrical connection | ||
● for main current circuit | screw-type terminals | |
● for auxiliary and control current circuit | screw-type terminals | |
Type of connectable conductor cross-sections | ||
● for main contacts | ||
— solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²) | |
— single or multi-stranded | 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²) | |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) | |
● at AWG conductors for main contacts | 2x (20 ... 16), 2x (18 ... 14), 1x 12 | |
Type of connectable conductor cross-sections | ||
● for auxiliary contacts | ||
— solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²) | |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) | |
● at AWG conductors for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14), 1x 12 |
Title: | Size: | Type: |
---|---|---|
3RT1317-1AP00 SIEMENS CONTACTOR, AC-1, 14,5KW/400 V, AC-1 22 A, AC 230 V, 50 HZ, 4-POLE, 4 NO, SIZE S00, | 80 Kbytes |
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.