power contactor, AC-3 115 A, 55 kW / 400 V AC (50-60 Hz) / DC operation 200-277 V AC/DC auxiliary contacts 2 NO + 2 NC 3-pole, frame size S6 busbar connections drive: electronic with PLC interface 24 V DC screw terminal

SIRIUS Contactor, 55KW/400V/AC-3 AC/DC drive 200-277V Auxiliary contacts 2 NA+2NC 3 poles, size S6 Electronic drive bar connections With SPS DC 24 V interface. Manufactured to order without possibility of return or cancellation.

More details


Low-voltage industrial components > Power contactor, AC switching

CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $521.70
Unit price: $521.70

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

More info



Technical data

power contactor, AC-3 115 A, 55 kW / 400 V AC (50-60 Hz) / DC operation 200-277 V AC/DC auxiliary contacts 2 NO + 2 NC 3-pole, frame size S6 busbar connections drive: electronic with PLC interface 24 V DC screw terminal
product brand nameSIRIUS
product designationPower contactor
product type designation3RT1
General technical data
size of contactorS6
product extension
● function module for communicationNo
● auxiliary switchYes
power loss [W] for rated value of the current
● at AC in hot operating state21 W
● at AC in hot operating state per pole7 W
● without load current share typical2.8 W
insulation voltage
● of main circuit with degree of pollution 3 rated value1 000 V
● of auxiliary circuit with degree of pollution 3 rated value500 V
surge voltage resistance
● of main circuit rated value8 kV
● of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1690 V
shock resistance at rectangular impulse
● at AC8,5g / 5 ms, 4,2g / 10 ms
● at DC8,5g / 5 ms, 4,2g / 10 ms
shock resistance with sine pulse
● at AC13,4g / 5 ms, 6,5g / 10 ms
● at DC13,4g / 5 ms, 6,5g / 10 ms
mechanical service life (switching cycles)
● of contactor typical10 000 000
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)05/01/2012
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
operating voltage
● at AC-3 rated value maximum1 000 V
● at AC-3e rated value maximum1 000 V
operational current
● at AC-1 at 400 V at ambient temperature 40 °C rated value160 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value160 A
— up to 690 V at ambient temperature 60 °C rated value140 A
— up to 1000 V at ambient temperature 40 °C rated value80 A
— up to 1000 V at ambient temperature 60 °C rated value80 A
● at AC-3
— at 400 V rated value115 A
— at 500 V rated value115 A
— at 690 V rated value115 A
— at 1000 V rated value53 A
● at AC-3e
— at 400 V rated value115 A
— at 500 V rated value115 A
— at 690 V rated value115 A
— at 1000 V rated value53 A
● at AC-4 at 400 V rated value97 A
● at AC-5a up to 690 V rated value140 A
● at AC-5b up to 400 V rated value95 A
● at AC-6a
— up to 230 V for current peak value n=20 rated value115 A
— up to 400 V for current peak value n=20 rated value115 A
— up to 500 V for current peak value n=20 rated value115 A
— up to 690 V for current peak value n=20 rated value115 A
— up to 1000 V for current peak value n=20 rated value53 A
● at AC-6a
— up to 230 V for current peak value n=30 rated value98 A
— up to 400 V for current peak value n=30 rated value98 A
— up to 500 V for current peak value n=30 rated value98 A
— up to 690 V for current peak value n=30 rated value98 A
— up to 1000 V for current peak value n=30 rated value53 A
minimum cross-section in main circuit at maximum AC-1 rated value70 mm²
operational current for approx. 200000 operating cycles at AC-4
● at 400 V rated value54 A
● at 690 V rated value48 A
operational current
● at 1 current path at DC-1
— at 24 V rated value160 A
— at 110 V rated value18 A
— at 220 V rated value3.4 A
— at 440 V rated value0.8 A
— at 600 V rated value0.5 A
● with 2 current paths in series at DC-1
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value20 A
— at 440 V rated value3.2 A
— at 600 V rated value1.6 A
● with 3 current paths in series at DC-1
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value160 A
— at 440 V rated value11.5 A
— at 600 V rated value4 A
● at 1 current path at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value2.5 A
— at 220 V rated value0.6 A
— at 440 V rated value0.17 A
— at 600 V rated value0.12 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value2.5 A
— at 440 V rated value0.65 A
— at 600 V rated value0.37 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value160 A
— at 440 V rated value1.4 A
— at 600 V rated value0.75 A
operating power
● at AC-3
— at 230 V rated value37 kW
— at 400 V rated value55 kW
— at 500 V rated value75 kW
— at 690 V rated value110 kW
— at 1000 V rated value75 kW
● at AC-3e
— at 230 V rated value37 kW
— at 400 V rated value55 kW
— at 500 V rated value75 kW
— at 690 V rated value110 kW
— at 1000 V rated value75 kW
operating power for approx. 200000 operating cycles at AC-4
● at 400 V rated value29 kW
● at 690 V rated value48 kW
operating apparent power at AC-6a
● up to 230 V for current peak value n=20 rated value40 000 kVA
● up to 400 V for current peak value n=20 rated value80 000 VA
● up to 500 V for current peak value n=20 rated value100 000 VA
● up to 690 V for current peak value n=20 rated value130 000 VA
● up to 1000 V for current peak value n=20 rated value90 000 VA
operating apparent power at AC-6a
● up to 230 V for current peak value n=30 rated value30 000 VA
● up to 400 V for current peak value n=30 rated value60 000 VA
● up to 500 V for current peak value n=30 rated value80 000 VA
● up to 690 V for current peak value n=30 rated value110 000 VA
● up to 1000 V for current peak value n=30 rated value90 000 VA
short-time withstand current in cold operating state up to 40 °C
● limited to 1 s switching at zero current maximum2 565 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum1 654 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 10 s switching at zero current maximum1 170 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum729 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum572 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency
● at AC1 000 1/h
● at DC1 000 1/h
operating frequency
● at AC-1 maximum800 1/h
● at AC-2 maximum400 1/h
● at AC-3 maximum1 000 1/h
● at AC-3e maximum1 000 1/h
● at AC-4 maximum130 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage at AC
● at 50 Hz rated value200 ... 277 V
● at 60 Hz rated value200 ... 277 V
control supply voltage at DC
● rated value200 ... 277 V
type of PLC-control input according to IEC 60947-1Type 2
consumed current at PLC-control input according to IEC 60947-1 maximum20 mA
voltage at PLC-control input rated value24 V
operating range factor of the voltage at PLC-control input0.8 ... 1.1
operating range factor control supply voltage rated value of magnet coil at DC
● initial value0.8
● full-scale value1.1
operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.8 ... 1.1
design of the surge suppressorwith varistor
apparent pick-up power of magnet coil at AC
● at 50 Hz280 VA
● at 60 Hz280 VA
inductive power factor with closing power of the coil
● at 50 Hz0.8
● at 60 Hz0.8
apparent holding power of magnet coil at AC
● at 50 Hz4.4 VA
● at 60 Hz4.4 VA
inductive power factor with the holding power of the coil
● at 50 Hz0.5
● at 60 Hz0.5
closing power of magnet coil at DC320 W
holding power of magnet coil at DC2.8 W
closing delay
● at AC35 ... 75 ms
● at DC35 ... 75 ms
opening delay
● at AC80 ... 90 ms
● at DC80 ... 90 ms
arcing time10 ... 15 ms
control version of the switch operating mechanismPLC-IN or Standard A1 - A2 (adjustable)
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact2
number of NO contacts for auxiliary contacts instantaneous contact2
operational current at AC-12 maximum10 A
operational current at AC-15
● at 230 V rated value6 A
● at 400 V rated value3 A
● at 500 V rated value2 A
● at 690 V rated value1 A
operational current at DC-12
● at 24 V rated value10 A
● at 48 V rated value6 A
● at 60 V rated value6 A
● at 110 V rated value3 A
● at 125 V rated value2 A
● at 220 V rated value1 A
● at 600 V rated value0.15 A
operational current at DC-13
● at 24 V rated value10 A
● at 48 V rated value2 A
● at 60 V rated value2 A
● at 110 V rated value1 A
● at 125 V rated value0.9 A
● at 220 V rated value0.3 A
● at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value124 A
● at 600 V rated value125 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 230 V rated value25 hp
● for 3-phase AC motor
— at 200/208 V rated value40 hp
— at 220/230 V rated value50 hp
— at 460/480 V rated value100 hp
— at 575/600 V rated value125 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 requiredgG: 355 A (690 V, 100 kA)
— with type of assignment 2 requiredgG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening methodscrew fixing
● side-by-side mountingYes
height172 mm
width120 mm
depth170 mm
required spacing
● with side-by-side mounting
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
● for grounded parts
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
● for live parts
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
type of electrical connection
● for main current circuitConnection bar
● for auxiliary and control circuitscrew-type terminals
● at contactor for auxiliary contactsScrew-type terminals
● of magnet coilScrew-type terminals
width of connection bar17 mm
thickness of connection bar3 mm
diameter of holes9 mm
number of holes1
type of connectable conductor cross-sections
● at AWG cables for main contacts4 ... 250 kcmil
connectable conductor cross-section for main contacts
● stranded25 ... 120 mm²
connectable conductor cross-section for auxiliary contacts
● solid or stranded0.5 ... 4 mm²
● finely stranded with core end processing0.5 ... 2.5 mm²
type of connectable conductor cross-sections
● for auxiliary contacts
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
AWG number as coded connectable conductor cross section
● for auxiliary contacts18 ... 14
Safety related data
product function
● mirror contact according to IEC 60947-4-1Yes
● positively driven operation according to IEC 60947-5-1No
B10 value with high demand rate according to SN 319201 000 000
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover
suitability for use
● safety-related switching OFFYes
Certificates/ approvals

Downloads and manuals

General Product Approval

CSA

Confirmation

CCC

UL

KC

EAC

EMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest Certificates

RCM

Type Examination Certificate

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Type Test Certificates/Test Report

Special Test Certificate

Marine / Shippingother

ABS (American Bureau of Shipping)

LR (Lloyds Register)

PRS / Polski Rejestr Statkow

RMRS / Russian Maritime Register

DNV-GL

Miscellaneous

otherRailway

Confirmation

Miscellaneous

Confirmation

Special Test Certificate

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:3/24/2022
Date
5/8/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RT1054-6NP36
Product Descriptionpower contactor, AC-3 115 A, 55 kW / 400 V AC (50-60 Hz) / DC operation 200-277 V AC/DC auxiliary contacts 2 NO + 2 NC 3-pole, frame size S6 busbar connections drive: electronic with PLC interface 24 V DC screw terminal
Product familySIRIUS 3RT contactors, 3-pole, up to 250 kW
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41B / 41B
Surcharge for Raw MaterialsNone
Metal FactorLFO-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works50 Day/Days
Net Weight (kg)3,310 Kg
Packaging Dimension190,00 x 129,00 x 181,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209507227
UPC754554773636
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group3706
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead titanium zirconium oxide

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Perfluorobutane sulfonic acid (PFBS) and its salts

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-10-03
eClass7.127-37-10-03
eClass827-37-10-03
eClass927-37-10-03
eClass9.127-37-10-03
ETIM5EC000066
ETIM6EC000066
ETIM7EC000066
ETIM8EC000066
IDEA44755
UNSPSC1439-12-15-21
UNSPSC1539-12-15-29

ETIM data

ETIM: EC000066 - Power contactor, AC switching

Value Unit
Type of electrical connection of main circuit (EF006819) -
Rated control supply voltage Us at AC 50HZ (EF003978) ['200.0', '277.0']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['200.0', '277.0']V
Rated control supply voltage Us at DC (EF003980) ['200', '277']V
Voltage type for actuating (EF008242) AC/DC
Rated operation current Ie at AC-1, 400 V (EF001393) 160A
Rated operation current Ie at AC-3, 400 V (EF001392) 115A
Rated operation power at AC-3, 400 V (EF001364) 55.0kW
Rated operation current Ie at AC-4, 400 V (EF008495) 97A
Rated operation power at AC-4, 400 V (EF008496) 55.0kW
Rated operation power NEMA (EF011960) 73.549875kW
Modular version (EF001126) true
Number of auxiliary contacts as normally open contact (EF001376) 2
Number of auxiliary contacts as normally closed contact (EF001377) 2
Number of normally closed contacts as main contact (EF001375) -
Number of main contacts as normally open contact (EF001374) 3


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.