ANUNCIAR
3RS2900-2AA30 SIEMENS Sensor extension module for 3RS26/8 Temperature monitoring relay, 2 sensors, sensor st.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RS2900-2AA30 SIEMENS Sensor extension module for 3RS26/8 Temperature monitoring relay, 2 sensors, sensor st..

3RS2900-2AA30

SIEMENS

Sensor extension module for 3RS26/8 Temperature monitoring relay, 2 sensors, sensor status relay, analog input, 22.5 mm width, 24 V AC/DC, spring-type terminals (push-in)

Sensor expansion module for 3RS26/8 relay temperature monitoring, 2 sensors, sensor status relay, analog input, width 22.5 mm, 24 V AC/DC, spring connection (quick insertion)

More details


CONTROL AND CONTACTORS > Function relays

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $213.42
Unit price: $213.42
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Sensor extension module for 3RS26/8 Temperature monitoring relay, 2 sensors, sensor status relay, analog input, 22.5 mm width, 24 V AC/DC, spring-type terminals (push-in)
product brand nameSIRIUS
product designationSensor extension module
design of the product2 additional resistivity sensors, analog input 4 ... 20 mA, ATEX via analog input, status relay
product type designation3RS2
General technical data
product functiontemperature monitoring
display version LEDYes
insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
test voltage for isolation test4 kV
degree of pollution3
protection class IP20
shock resistance according to IEC 60068-2-2711g / 15 ms
vibration resistance according to IEC 60068-2-610 ... 55 Hz: 0.35 mm
switching behaviormonostable
mechanical service life (switching cycles) typical10 000 000
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
thermal current of the switching element with contacts maximum5 A
certificate of suitability relating to ATEXYes, with digital unit 3RS26/3RS28
reference code according to IEC 81346-2K
influence of the surrounding temperature0.05% per K deviation from T20
measurable temperature
● initial value-50 °C
● full-scale value750 °C
measurable Fahrenheit temperature
● initial value-58 °F
● full-scale value1 382 °F
Substance Prohibitance (Date)05/01/2012
product function
● error memoryYes
● external resetYes
design of the sensor connectableResistance sensors: Pt100, Pt1000, KTY83-110, KTY84, NTC
measurable temperature with KTY-sensor maximum300 °C
sensor current with KTY-sensor0.33 mA
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage at AC
● at 50 Hz rated value24 ... 24 V
● at 60 Hz rated value24 ... 24 V
control supply voltage 1 at AC
● at 50 Hz rated value24 V
● at 50 Hz24 ... 24 V
● at 60 Hz rated value24 V
● at 60 Hz24 ... 24 V
control supply voltage 2 at AC
● at 50 Hz rated value24 V
● at 60 Hz rated value24 V
control supply voltage at DC rated value24 ... 24 V
control supply voltage 1
● at DC rated value24 V
● at DC24 ... 24 V
operating range factor control supply voltage rated value at DC
● initial value0.85
● full-scale value1.1
operating range factor control supply voltage rated value at AC at 50 Hz
● initial value0.85
● full-scale value1.1
operating range factor control supply voltage rated value at AC at 60 Hz
● initial value0.85
● full-scale value1.1
supply voltage frequency for auxiliary and control circuit50 ... 60 Hz
number of measuring circuits3
buffering time in the event of power failure minimum20 ms
Precision
relative metering precision1 %
Short-circuit protection
design of the fuse link
● for short-circuit protection of the NO contacts of the relay outputs requiredgL/gG: 6 A or MCB type C: 1 A
● for short circuit protection of the NC contacts of the relay outputs requiredgL/gG: 6 A or MCB type C: 1 A
design of the fuse link
● for short-circuit protection of the NO contacts of the relay outputs safety-related requiredgL/gG: 2 A or MCB type C: 1 A
● for short circuit protection of the NC contacts of the relay outputs safety-related requiredgL/gG: 2 A or MCB type C: 1 A
Communication/ Protocol
protocol is supported IO-Link protocolNo
Auxiliary circuit
material of switching contactsAgSnO2
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts1
number of CO contacts for auxiliary contacts0
operational current of auxiliary contacts at DC-13
● at 24 V1 A
● at 125 V0.2 A
● at 250 V0.1 A
contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
contact rating of auxiliary contacts according to ULR300 / B300
operating frequency rated value50 ... 60 Hz
ampacity of the output relay at AC-15 at 250 V at 50/60 Hz3 A
ampacity of the output relay at DC-13
● at 24 V1 A
● at 125 V0.2 A
continuous current of the DIAZED fuse link of the output relay6 A
continuous current of DIAZED fuse link of the output relay safety-related2 A
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1Class B
conducted interference
● due to burst according to IEC 61000-4-42 kV (power ports), 1 kV (signal ports)
● due to conductor-earth surge according to IEC 61000-4-52 kV (line to ground)
● due to conductor-conductor surge according to IEC 61000-4-51 kV (line to line)
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
Galvanic isolation
design of the electrical isolationgalvanic isolation
galvanic isolation
● between input and outputYes
● between the voltage supply and other circuitsNo
Safety related data
Safety Integrity Level (SIL) according to IEC 615081
SIL Claim Limit (subsystem) according to EN 620611
performance level (PL) according to EN ISO 13849-1c
category according to EN ISO 13849-11
Safe failure fraction (SFF)66 %
PFHD with high demand rate according to EN 620610.00000026 1/h
hardware fault tolerance according to IEC 615080
Connections/ Terminals
product component removable terminal for auxiliary and control circuitYes
type of electrical connectionspring-loaded terminal (push-in)
● for auxiliary and control circuitspring-loaded terminals (push-in)
type of connectable conductor cross-sections
● solid0.5 ... 4 mm²
● finely stranded with core end processing0.5 ... 2.5 mm²
● finely stranded without core end processing0.5 ... 4 mm²
● at AWG cables solid20 ... 12
● at AWG cables stranded20 ... 12
connectable conductor cross-section
● solid0.5 ... 4 mm²
● finely stranded with core end processing0.5 ... 2.5 mm²
● finely stranded without core end processing0.5 ... 4 mm²
AWG number as coded connectable conductor cross section
● solid20 ... 12
● stranded20 ... 12
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
height100 mm
width22.5 mm
depth90 mm
required spacing
● with side-by-side mounting
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
● for grounded parts
— forwards0 mm
— backwards0 mm
— upwards0 mm
— at the side0 mm
— downwards0 mm
● for live parts
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-40 ... +85 °C
● during transport-40 ... +85 °C
relative humidity during operation70 %
explosion protection category for dustEx II (2) D [b1] [Ex h] [pyb] [tb] [mb] [kb] [sb] III C Db
explosion protection category for gasEx II (2) G [b1] [Ex h] [db] [eb] [pyb] [mb] [ob] [q] [kb] [sb] II C Gb
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMC

CSA

CCC

Confirmation

UL

EAC

RCM

For use in hazardous locationsFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / Shipping

ATEX-EC-Type-Examination-Certificate

Type Examination Certificate

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Special Test Certificate

DNV-GL

other

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Derating
last modified:1/27/2022
Date
5/14/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RS2900-2AA30
Product DescriptionSensor extension module for 3RS26/8 Temperature monitoring relay, 2 sensors, sensor status relay, analog input, 22.5 mm width, 24 V AC/DC, spring-type terminals (push-in)
Product familySIRIUS 3RS2 temperature monitoring relays
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41H / 41H
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works10 Day/Days
Net Weight (kg)0,169 Kg
Packaging Dimension111,00 x 126,00 x 38,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047621058740
UPC195125059368
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group4947
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-18-10
eClass7.127-37-18-10
eClass827-37-18-10
eClass927-37-18-10
eClass9.127-37-18-10
ETIM5EC001446
ETIM6EC001446
ETIM7EC001446
ETIM8EC001446
IDEA45282
UNSPSC1539-12-22-29

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.