Monitoring relay, can be mounted to Contactor 3RT2, Size S0 basic, analog adjustment Apparent current monitoring 4...40 A, 50...60 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system
CONTROL AND CONTACTORS > Thermal relays
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product | ||||||||||||||||||||||||||||||||||||||||
Article Number (Market Facing Number) | 3RR2142-1AA30 | |||||||||||||||||||||||||||||||||||||||
Product Description | Monitoring relay, can be mounted to Contactor 3RT2, Size S0 basic, analog adjustment Apparent current monitoring 4...40 A, 50...60 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system | |||||||||||||||||||||||||||||||||||||||
Product family | Current and active current monitoring | |||||||||||||||||||||||||||||||||||||||
Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
Price data | ||||||||||||||||||||||||||||||||||||||||
Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
Delivery information | ||||||||||||||||||||||||||||||||||||||||
Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
Standard lead time ex-works | 60 Day/Days | |||||||||||||||||||||||||||||||||||||||
Net Weight (kg) | 0,263 Kg | |||||||||||||||||||||||||||||||||||||||
Packaging Dimension | 99,00 x 115,00 x 57,00 | |||||||||||||||||||||||||||||||||||||||
Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
EAN | 4011209787254 | |||||||||||||||||||||||||||||||||||||||
UPC | 662643908602 | |||||||||||||||||||||||||||||||||||||||
Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
Product Group | 5343 | |||||||||||||||||||||||||||||||||||||||
Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
Country of origin | Czech Republic | |||||||||||||||||||||||||||||||||||||||
Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | |||||||||||||||||||||||||||||||||||||||
Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
Classifications | ||||||||||||||||||||||||||||||||||||||||
|
Value | Unit | |
---|---|---|
External current transformer (EF001923) | - | |
Type of electric connection (EF003961) | Screw connection | |
With detachable clamps (EF003340) | true | |
Single-phase under current possible (EF003405) | false | |
Three-phase under current possible (EF003406) | false | |
Single-phase over current possible (EF003407) | false | |
Three-phase over current possible (EF003408) | false | |
Single-phase hysteresis possible (EF003394) | false | |
Three-phase hysteresis possible (EF003395) | false | |
Contains function DC-voltage under current (EF003409) | false | |
Contains function DC-voltage over current (EF003410) | false | |
Function DC-current hysteresis (EF003411) | false | |
Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '24'] | V |
Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '24'] | V |
Rated control supply voltage Us at DC (EF003980) | ['-', '24'] | V |
Voltage type for actuating (EF008242) | AC/DC | |
Current measurement range (EF000417) | ['4.0', '40.0'] | A |
Min. adjustable delay-on energization time (EF008190) | 0 | s |
Max. permitted delay-on energization time (EF008189) | 60 | s |
Min. adjustable off-delay time (EF008192) | 0 | s |
Max. permitted off-delay time (EF008191) | 30 | s |
Number of contacts as normally closed contact (EF008255) | - | |
Number of contacts as normally open contact (EF008256) | - | |
Number of contacts as change-over contact (EF008257) | - | |
Width (EF000008) | 45.0 | mm |
Height (EF000040) | 87.0 | mm |
Depth (EF000049) | 91.0 | mm |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes | |
3RR2142-1AA30 3RR2142-1AA30 EN_3RR2142-1AA30.pdf | 254 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.