3RM1001-3AA14 SIEMENS Direct starter, 3RM1, 500 V, 0 0.12 kW, 0.1 0.5 A, 110-230 V AC, screw/spring-type ter.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RM1001-3AA14 SIEMENS Direct starter, 3RM1, 500 V, 0 0.12 kW, 0.1 0.5 A, 110-230 V AC, screw/spring-type ter..

3RM1001-3AA14

SIEMENS

Direct starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A, 110-230 V AC, screw/spring-type terminals

More details


CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $224.93
Unit price: $224.93

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

More info



Technical data

Direct starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A, 110-230 V AC, screw/spring-type terminals
product brand nameSIRIUS
product categoryMotor starter
product designationDirect-on-line starter
design of the productwith electronic overload protection
product type designation3RM1
General technical data
trip classCLASS 10A
equipment variant according to IEC 60947-4-23
product functionDirect-on-line starter
● intrinsic device protectionYes
● for power supply reverse polarity protectionNo
suitability for operation device connector 3ZY12No
insulation voltage rated value500 V
overvoltage categoryIII
surge voltage resistance rated value6 kV
maximum permissible voltage for safe isolation
● between main and auxiliary circuit500 V
● between control and auxiliary circuit250 V
shock resistance6g / 11 ms
vibration resistance1 ... 6 Hz, 15 mm; 20 m/s², 500 Hz
operating frequency maximum1 1/s
mechanical service life (switching cycles) typical30 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)03/01/2017
product function
● direct startYes
● reverse startingNo
product function short circuit protectionNo
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1class A
EMC immunity according to IEC 60947-1Class A
conducted interference
● due to burst according to IEC 61000-4-43 kV / 5 kHz
● due to conductor-earth surge according to IEC 61000-4-52 kV
● due to conductor-conductor surge according to IEC 61000-4-51 kV
● due to high-frequency radiation according to IEC 61000-4-610 V
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according to CISPR11Class B for domestic, business and commercial environments; Class A for industrial environments at 110 V DC
field-bound HF interference emission according to CISPR11Class B for domestic, business and commercial environments; Class A for industrial environments at 110 V DC
Safety related data
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe
Main circuit
number of poles for main current circuit3
design of the switching contactHybrid
design of the switching contact as NO contact for signaling functionOUT, electronic, 24 V DC, 15 mA
adjustable current response value current of the current-dependent overload release0.1 ... 0.5 A
minimum load [%]20 %; from set rated current
type of the motor protectionsolid-state
operating voltage rated value48 ... 500 V
relative symmetrical tolerance of the operating voltage10 %
operating frequency 1 rated value50 Hz
operating frequency 2 rated value60 Hz
relative symmetrical tolerance of the operating frequency10 %
operational current
● at AC at 400 V rated value0.5 A
● at AC-3 at 400 V rated value0.5 A
● at AC-53a at 400 V at ambient temperature 40 °C rated value0.5 A
ampacity when starting maximum4 A
operating power for 3-phase motors at 400 V at 50 Hz0 ... 0.12 kW
Inputs/ Outputs
input voltage at digital input
● at DC rated value110 V
● with signal <0> at DC0 ... 40 V
● for signal <1> at DC79 ... 121
input voltage at digital input
● at AC rated value110 V
● with signal <0> at AC0 ... 40 V
● for signal <1> at AC93 ... 253 V
input current at digital input
● for signal <1> at DC1.5 mA
● with signal <0> at DC0.25 mA
input current at digital input with signal <0> at AC
● at 110 V0.2 mA
● at 230 V0.4 mA
input current at digital input for signal <1> at AC
● at 110 V1.1 mA
● at 230 V2.3 mA
number of CO contacts for auxiliary contacts1
operational current of auxiliary contacts at AC-15 at 230 V maximum3 A
operational current of auxiliary contacts at DC-13 at 24 V maximum1 A
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
control supply voltage at AC
● at 50 Hz rated value110 ... 230 V
● at 60 Hz rated value110 ... 230 V
relative negative tolerance of the control supply voltage at AC at 60 Hz15 %
relative positive tolerance of the control supply voltage at AC at 60 Hz10 %
control supply voltage 1 at AC
● at 50 Hz110 ... 230 V
● at 60 Hz110 ... 230 V
control supply voltage frequency
● 1 rated value50 Hz
● 2 rated value60 Hz
relative negative tolerance of the control supply voltage at DC15 %
relative positive tolerance of the control supply voltage at DC10 %
control supply voltage 1 at DC rated value110 V
operating range factor control supply voltage rated value at DC
● initial value0.85
● full-scale value1.1
operating range factor control supply voltage rated value at AC at 50 Hz
● initial value0.85
● full-scale value1.1
operating range factor control supply voltage rated value at AC at 60 Hz
● initial value0.85
● full-scale value1.1
control current at AC
● at 110 V in standby mode of operation16 mA
● at 230 V in standby mode of operation9 mA
● at 110 V when switching on55 mA
● at 230 V when switching on33 mA
● at 110 V during operation36 mA
● at 230 V during operation22 mA
control current at DC
● in standby mode of operation6 mA
● when switching on15 mA
● during operation30 mA
power loss [W] in auxiliary and control circuit
● in switching state OFF
— with bypass circuit2.1 W
● in switching state ON
— with bypass circuit5.06 W
Response times
ON-delay time60 ... 90 ms
OFF-delay time60 ... 90 ms
Power Electronics
operational current
● at 40 °C rated value0.5 A
● at 50 °C rated value0.5 A
● at 55 °C rated value0.5 A
● at 60 °C rated value0.5 A
Installation/ mounting/ dimensions
mounting positionvertical, horizontal, standing (observe derating)
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
height100 mm
width22.5 mm
depth141.6 mm
required spacing
● with side-by-side mounting
— forwards0 mm
— backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side0 mm
● for grounded parts
— forwards0 mm
— backwards0 mm
— upwards50 mm
— at the side3.5 mm
— downwards50 mm
Ambient conditions
installation altitude at height above sea level maximum4 000 m; For derating see manual
ambient temperature
● during operation-25 ... +60 °C
● during storage-40 ... +70 °C
● during transport-40 ... +70 °C
environmental category during operation according to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
relative humidity during operation10 ... 95 %
air pressure according to SN 31205900 ... 1 060 hPa
Communication/ Protocol
protocol is supported
● PROFINET IO protocolNo
● PROFIsafe protocolNo
product function bus communicationNo
protocol is supported AS-Interface protocolNo
Connections/ Terminals
type of electrical connectionscrew-type terminals for main circuit, spring-loaded terminals (push-in) for control circuit
● for main current circuitscrew-type terminals
● for auxiliary and control circuitspring-loaded terminals (push-in)
wire length for motor unshielded maximum100 m
type of connectable conductor cross-sections
● for main contacts
— solid1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)
— finely stranded with core end processing1x (0,5 … 4 mm²), 2x (0,5 … 1,5 mm²)
● at AWG cables for main contacts1x (20 ... 12), 2x (20 ... 14)
connectable conductor cross-section for main contacts
● solid or stranded0.5 ... 4 mm²
● finely stranded with core end processing0.5 ... 4 mm²
connectable conductor cross-section for auxiliary contacts
● solid or stranded0.5 ... 1.5 mm²
● finely stranded with core end processing0.5 ... 1 mm²
● finely stranded without core end processing0.5 ... 1.5 mm²
type of connectable conductor cross-sections
● for auxiliary contacts
— solid1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
— finely stranded with core end processing1x (0,5 ... 1,0 mm²), 2x (0,5 ... 1,0 mm²)
— finely stranded without core end processing1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
● at AWG cables for auxiliary contacts1x (20 ... 16), 2x (20 ... 16)
AWG number as coded connectable conductor cross section
● for main contacts20 ... 12
● for auxiliary contacts20 ... 16
UL/CSA ratings
operating voltage at AC
● according to UL rated value480 V
● according to CSA rated value400 V
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMC

CSA

Confirmation

CCC

UL

EAC

RCM

Declaration of Conformityother

EC/EU-Declaration of Conformity

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:11/3/2021
Date
5/3/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RM1001-3AA14
Product DescriptionDirect starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A, 110-230 V AC, screw/spring-type terminals
Product familySIRIUS 3RM1 motor starters
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41D / 41D
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-worksOn request
Net Weight (kg)0,310 Kg
Packaging Dimension36,00 x 109,00 x 167,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209935877
UPC887621293383
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group3762
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.03.2017
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

4,4'-isopropylidenediphenol (Bisphenol A, BPA)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Diboron trioxide

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-09-05
eClass7.127-37-09-05
eClass827-37-09-05
eClass927-37-09-05
eClass9.127-37-09-05
ETIM5EC001037
ETIM6EC001037
ETIM7EC001037
ETIM8EC001037
UNSPSC1539-12-15-21

ETIM data

ETIM: EC001037 - Motor starter/Motor starter combination

Value Unit
Number of indicator lights (EF001965) -
Type of motor starter (EF009598) -
Supporting protocol for EtherNet/IP (EF007521) -
Supporting protocol for other bus systems (EF003062) -
Suitable for emergency stop (EF001433) -
Coordination class according to IEC 60947-4-3 (EF012390) -
Rated operation current at AC-3, 400 V (EF009602) -A
Supporting protocol for Data-Highway (EF003058) -
Supporting protocol for TCP/IP (EF003050) -
Number of auxiliary contacts as normally closed contact (EF001377) -
Temperature compensated overload protection (EF009604) -
Rated conditional short-circuit current, type 2, 230 V (EF009606) -A
Rated conditional short-circuit current, type 2, 400 V (EF009605) -A
Ambient temperature, upper operating limit (EF009603) -°C
Supporting protocol for DeviceNet (EF003059) -
Supporting protocol for INTERBUS (EF003054) -
Number of auxiliary contacts as normally open contact (EF001376) -
Supporting protocol for AS-Interface Safety at Work (EF007519) -
Supporting protocol for Modbus (EF003057) -
Degree of protection (NEMA) (EF011959) -
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) -A
Supporting protocol for PROFIsafe (EF007526) -
Supporting protocol for PROFINET IO (EF007525) -
Supporting protocol for PROFIBUS (EF003052) -
Supporting protocol for DeviceNet Safety (EF007520) -
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) -A
Supporting protocol for LON (EF003017) -
External reset possible (EF003426) -
Rail mounting possible (EF003972) -
Supporting protocol for SafetyBUS p (EF007527) -
Rated operation power at AC-3, 230 V, 3-phase (EF009599) -kW
Supporting protocol for ASI (EF003051) -
Supporting protocol for CAN (EF003053) -
Supporting protocol for SERCOS (EF006657) -
Supporting protocol for INTERBUS-Safety (EF006662) -
Supporting protocol for PROFINET CBA (EF007524) -
Supporting protocol for Foundation Fieldbus (EF007522) -
Rated power, 575 V, 60 Hz, 3-phase (EF009601) -kW
Supporting protocol for SUCONET (EF003060) -
With short-circuit release (EF006691) false
Rated control supply voltage Us at AC 50HZ (EF003978) ['110', '230']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['110', '230']V
Rated control supply voltage Us at DC (EF003980) ['110', '110']V
Voltage type for actuating (EF008242) AC/DC
Rated operation power at AC-3, 400 V (EF001364) 0.12kW
Rated operation current Ie (EF001443) 0.5A
Overload release current setting (EF002336) ['0.5', '0.5']A
Release class (EF006668) CLASS 10 A
Type of electrical connection of main circuit (EF006819) Screw connection
Type of electrical connection for auxiliary- and control current circuit (EF006979) Other
With transformer (EF000278) false
Number of command positions (EF001372) 0
With fuse (EF006693) false
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 22.5mm
Height (EF000040) 100.0mm
Depth (EF000049) 141.6mm
Rated power, 460 V, 60 Hz, 3-phase (EF009600) -kW


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.