SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Standard Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 180 V DC 4 DI / 1 DO AS-i Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch
START. MOTOR SIRIUS M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT STARTER STANDARD MECHANICAL MANEUVER 3 AC 400V/0,9KW; 0,15A... 2.00A; PROTEC. OVERC. ELECTRONICS; THERMISTOR: TERMOCLICK / PTC WITH BRAKE CONTACT 180V DC 4DI / 1DO AS-I HAN Q4/2 - HAN Q8/0 WITH LOCAL MANUAL CONTROL AND SECURITY LOCK. Manufactured to order. Non-Cancelable Non-Returnable.
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > AS-Interface switchgear, SIMOCODE
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1325-6KS41-2AA5 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Standard Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 180 V DC 4 DI / 1 DO AS-i Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch | ||||||||||||||||||||||||||||||||||||
| Product family | M200D Standard motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | On request | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 4,261 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 287,00 x 377,00 x 221,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209823495 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643543711 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3722 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
| Value | Unit | |
|---|---|---|
| Rail mounting possible (EF003972) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| With fuse (EF006693) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Number of command positions (EF001372) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Degree of protection (NEMA) (EF011959) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Type of motor starter (EF009598) | Direct online starter (DOL) | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.75 | kW |
| Rated operation current Ie (EF001443) | 2 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 2 | A |
| Overload release current setting (EF002336) | ['0.15', '2'] | A |
| Release class (EF006668) | Other | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP65 | |
| Supporting protocol for ASI (EF003051) | true | |
| Width (EF000008) | 294.0 | mm |
| Height (EF000040) | 215.0 | mm |
| Depth (EF000049) | 159.0 | mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 3RK1325-6KS41-2AA5 3RK1325-6KS41-2AA5 EN_3RK1325-6KS41-2AA5.pdf | 323 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.