Product successfully added to your shopping cart
3RK1315-6KS41-1AA0
SIEMENS
1
SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter Basic Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 2DI AS-i + 2DI / 1DO on device Han Q4/2 - Han Q8/0
SIRIUS ARRANCANC. MOTOR M200D AS-I COMMUNICATION: AS-ENTERFACE STARTERS INVERTERS BASIC MECHANICAL CLOSURE 3 AC 400V/0,9KW; 0,15A... 2.00A; PROTEC. ELECT. AGAINST OVERLOAD; THERMISTOR: THERMOCLICK / PTC NON-CONTACT BRAKE 2DI AS-I + 2DI / 1DO ON THE APPARATUS HAN Q4/2-HAN Q8/0. Manufactured to order. Non-Cancelable Non-Returnable.
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > AS-Interface switchgear, SIMOCODE
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1315-6KS41-1AA0 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter Basic Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 2DI AS-i + 2DI / 1DO on device Han Q4/2 - Han Q8/0 | ||||||||||||||||||||||||||||||||||||
| Product family | M200D Basic motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 100 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 3,870 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 287,00 x 377,00 x 221,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209823006 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643543902 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3722 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
| Value | Unit | |
|---|---|---|
| Number of command positions (EF001372) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Rail mounting possible (EF003972) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for Modbus (EF003057) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Number of indicator lights (EF001965) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| With fuse (EF006693) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Type of motor starter (EF009598) | Reversing starter | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.75 | kW |
| Rated operation current Ie (EF001443) | 2 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 2 | A |
| Overload release current setting (EF002336) | ['0.15', '2'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP65 | |
| Supporting protocol for ASI (EF003051) | true | |
| Width (EF000008) | 294.0 | mm |
| Height (EF000040) | 215.0 | mm |
| Depth (EF000049) | 159.0 | mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 3RK1315-6KS41-1AA0 3RK1315-6KS41-1AA0 EN_3RK1315-6KS41-1AA0.pdf | 320 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.