Product successfully added to your shopping cart
3RK1315-6KS41-0AA0
SIEMENS
1
SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Basic Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 2DI AS-i + 2DI / 1DO on device Han Q4/2 - Han Q8/0
SIRIUS STARTS. MOTOR M200D AS-I COMMUNICATION: AS-ENTERFACE DIRECT STARTER BASIC MECHANICAL CLOSURE 3 AC 400V/0.9KW; 0.15A... 2.00A; PROTEC. ELEC. AGAINST OVERLOAD; THERMISTOR:TERMOCLICK / PTC NON-CONTACT BRAKE 2DI AS-I + 2DI / 1ST ON HAN Q4/2-HAN Q8/0 APPARATUS
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > AS-Interface switchgear, SIMOCODE
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1315-6KS41-0AA0 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Basic Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 2DI AS-i + 2DI / 1DO on device Han Q4/2 - Han Q8/0 | ||||||||||||||||||||||||||||||||||||
| Product family | M200D Basic motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 100 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 3,700 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 287,00 x 377,00 x 221,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209822900 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643543872 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3722 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
| Value | Unit | |
|---|---|---|
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Number of indicator lights (EF001965) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Number of command positions (EF001372) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rail mounting possible (EF003972) | - | |
| Type of motor starter (EF009598) | Direct online starter (DOL) | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.75 | kW |
| Rated operation current Ie (EF001443) | 2 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 2 | A |
| Overload release current setting (EF002336) | ['0.15', '2'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP65 | |
| Supporting protocol for ASI (EF003051) | true | |
| Width (EF000008) | 294.0 | mm |
| Height (EF000040) | 215.0 | mm |
| Depth (EF000049) | 159.0 | mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 3RK1315-6KS41-0AA0 3RK1315-6KS41-0AA0 EN_3RK1315-6KS41-0AA0.pdf | 318 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.