3RB2153-4FW2 SIEMENS Overload relay 50...200 A for motor protection Size S6, CLASS 5...30E Contactor mountin.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RB2153-4FW2 SIEMENS Overload relay 50...200 A for motor protection Size S6, CLASS 5...30E Contactor mountin..

3RB2153-4FW2

SIEMENS

Overload relay 50...200 A for motor protection Size S6, CLASS 5...30E Contactor mounting/stand-alone installation Main circuit: straight-through transformer Auxiliary circuit: Screw terminal Manual-Automatic-Reset Internal ground fault detection

More details


Low-voltage industrial components > Electronic overload relay

CONTROL AND CONTACTORS > Thermal relays

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $365.90
Unit price: $365.90

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Technical data

Overload relay 50...200 A for motor protection Size S6, CLASS 5...30E Contactor mounting/stand-alone installation Main circuit: straight-through transformer Auxiliary circuit: Screw terminal Manual-Automatic-Reset Internal ground fault detection
product brand nameSIRIUS
product designationsolid-state overload relay
product type designation3RB2
General technical data
size of overload relayS6
size of contactor can be combined company-specificS6
insulation voltage with degree of pollution 3 at AC rated value1 000 V
surge voltage resistance rated value8 kV
maximum permissible voltage for safe isolation in networks with grounded star point
● between auxiliary and auxiliary circuit300 V
● between auxiliary and auxiliary circuit300 V
● between main and auxiliary circuit600 V
● between main and auxiliary circuit690 V
shock resistance15g / 11 ms
● according to IEC 60068-2-2715g / 11 ms
vibration resistance1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles
thermal current200 A
type of protection according to ATEX directive 2014/34/EUEx II (2) G [Ex e] [Ex d] [Ex px] ; Ex II (2) D [Ex t] [Ex p]
certificate of suitability according to ATEX directive 2014/34/EUPTB 06 ATEX 3001
reference code according to IEC 81346-2F
Substance Prohibitance (Date)07/01/2006
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-40 ... +80 °C
● during transport-40 ... +80 °C
temperature compensation-25 ... +60 °C
relative humidity during operation10 ... 95 %
Main circuit
number of poles for main current circuit3
adjustable current response value current of the current-dependent overload release50 ... 200 A
operating voltage
● rated value1 000 V
● for remote-reset function at DC24 V
● at AC-3e rated value maximum1 000 V
operating frequency rated value50 ... 60 Hz
operational current rated value200 A
operational current at AC-3e at 400 V rated value200 A
operating power
● for 3-phase motors at 400 V at 50 Hz30 ... 90 kW
● for AC motors at 500 V at 50 Hz30 ... 132 kW
● for AC motors at 690 V at 50 Hz55 ... 160 kW
Auxiliary circuit
design of the auxiliary switchintegrated
number of NC contacts for auxiliary contacts1
● notefor contactor disconnection
number of NO contacts for auxiliary contacts1
● notefor message "tripped"
number of CO contacts for auxiliary contacts0
operational current of auxiliary contacts at AC-15
● at 24 V4 A
● at 110 V4 A
● at 120 V4 A
● at 125 V4 A
● at 230 V3 A
operational current of auxiliary contacts at DC-13
● at 24 V2 A
● at 60 V0.55 A
● at 110 V0.3 A
● at 125 V0.3 A
● at 220 V0.11 A
Protective and monitoring functions
trip classCLASS 5E, 10E, 20E and 30E adjustable
design of the overload releaseelectronic
response value current of the grounding protection minimum0.75 x IMotor
response time of the grounding protection in settled state1 000 ms
operating range of the grounding protection relating to current set value
● minimumIMotor > lower current setting value
● maximumIMotor < upper current setting value x 3.5
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value200 A
● at 600 V rated value200 A
contact rating of auxiliary contacts according to ULB600 / R300
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 requiredgG: 355 A, Class L: 601 A
— with type of assignment 2 requiredgG: 315 A
● for short-circuit protection of the auxiliary switch requiredfuse gG: 6 A
Installation/ mounting/ dimensions
mounting positionany
fastening methodContactor mounting/stand-alone installation
height119 mm
width120 mm
depth155 mm
Connections/ Terminals
product component removable terminal for auxiliary and control circuitYes
type of electrical connection
● for main current circuitstraight-through transformers
● for auxiliary and control circuitscrew-type terminals
arrangement of electrical connectors for main current circuitTop and bottom
type of connectable conductor cross-sections
● for auxiliary contacts
— solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
— solid or stranded1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)
— finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
● at AWG cables for auxiliary contacts2x (20 ... 14)
tightening torque
● for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
design of the thread of the connection screw
● of the auxiliary and control contactsM3
Safety related data
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Communication/ Protocol
type of voltage supply via input/output link masterNo
Electromagnetic compatibility
conducted interference
● due to burst according to IEC 61000-4-42 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3
● due to conductor-earth surge according to IEC 61000-4-52 kV (line to earth) corresponds to degree of severity 3
● due to conductor-conductor surge according to IEC 61000-4-51 kV (line to line) corresponds to degree of severity 3
● due to high-frequency radiation according to IEC 61000-4-610 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
Display
display version for switching statusSlide switch
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMC

CSA

Confirmation

CCC

UL

EAC

RCM

For use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / Shipping

ATEX-EC-Type-Examination-Certificate

EC/EU-Declaration of Conformity

Type Test Certificates/Test Report

Special Test Certificate

ABS (American Bureau of Shipping)

LR (Lloyds Register)

Marine / Shippingother

RINA / Registro Italiano Navale

DNV-GL

Miscellaneous

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:2/9/2022
Date
5/14/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RB2153-4FW2
Product DescriptionOverload relay 50...200 A for motor protection Size S6, CLASS 5...30E Contactor mounting/stand-alone installation Main circuit: straight-through transformer Auxiliary circuit: Screw terminal Manual-Automatic-Reset Internal ground fault detection
Product family3RB20, 3RB21 for standard applications
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41G / 41G
Surcharge for Raw MaterialsNone
Metal FactorL-O-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works110 Day/Days
Net Weight (kg)0,720 Kg
Packaging Dimension144,00 x 178,00 x 137,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209638365
UPC040892553628
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5808
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-15-02
eClass7.127-37-15-02
eClass827-37-15-02
eClass927-37-15-02
eClass9.127-37-15-02
ETIM5EC001080
ETIM6EC001080
ETIM7EC001080
ETIM8EC001080
IDEA45365
UNSPSC1439-12-23-30
UNSPSC1539-12-23-30

ETIM data

ETIM: EC001080 - Electronic overload relay

Value Unit
Mounting method (EF000003) -
Reset function push-button (EF011942) -
Reset function input (EF011940) -
Reset function automatic (EF011941) -
Adjustable current range (EF008211) ['50', '200']A
Type of electrical connection of main circuit (EF006819) Through-feed current converter
Number of auxiliary contacts as normally closed contact (EF001377) 1
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as change-over contact (EF003531) 0
Rated control supply voltage Us at AC 50HZ (EF003978) ['-', '-']V
Rated control supply voltage Us at AC 60HZ (EF003979) ['-', '-']V
Rated control supply voltage Us at DC (EF003980) ['-', '-']V
Release class (EF006668) Adjustable
Voltage type for actuating (EF008242) -


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.