Product successfully added to your shopping cart
3RA2335-8XB30-1KB4
SIEMENS
1
Reversing contactor assembly, AC-3, 18.5 kW 400 V, 0.7...1.25 US DC, 24 V DC 3-pole, Size S2 screw terminal electrical and mechanical interlock 2 NO integrated Varistor mounted
COMB. INV., AC3:18,5KW/400V, DC 0,7...1,25 US, DC 24 V 3POL, TAM. S2 INTERLOCK SCREW TERMINALS. ELECTRICAL AND MECHANICAL 2NA INTEGRATED .. Manufactured to order. Non-Cancelable Non-Returnable.
Low-voltage industrial components > Combination of contactors
CONTROL AND CONTACTORS > Contactors for switching motors
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Reversing contactor assembly, AC-3, 18.5 kW 400 V, 0.7...1.25 US DC, 24 V DC 3-pole, Size S2 screw terminal electrical and mechanical interlock 2 NO integrated Varistor mounted | ||||||||||||||||||||||||||||||||||||||
product brand name | SIRIUS | |||||||||||||||||||||||||||||||||||||
product designation | Reversing contactor assembly | |||||||||||||||||||||||||||||||||||||
product type designation | 3RA23 | |||||||||||||||||||||||||||||||||||||
manufacturer's article number | ||||||||||||||||||||||||||||||||||||||
● 1 of the supplied contactor | 3RT2035-1KB40 | |||||||||||||||||||||||||||||||||||||
● 2 of the supplied contactor | 3RT2035-1KB40 | |||||||||||||||||||||||||||||||||||||
● of the supplied RS assembly kit | 3RA2933-2AA1 | |||||||||||||||||||||||||||||||||||||
General technical data | ||||||||||||||||||||||||||||||||||||||
size of contactor | S2 | |||||||||||||||||||||||||||||||||||||
product extension auxiliary switch | Yes | |||||||||||||||||||||||||||||||||||||
shock resistance at rectangular impulse | ||||||||||||||||||||||||||||||||||||||
● at DC | 7.7g / 5 ms, 4.5g / 10 ms | |||||||||||||||||||||||||||||||||||||
shock resistance with sine pulse | ||||||||||||||||||||||||||||||||||||||
● at DC | 12g / 5 ms, 7g / 10 ms | |||||||||||||||||||||||||||||||||||||
mechanical service life (switching cycles) | ||||||||||||||||||||||||||||||||||||||
● of contactor typical | 10 000 000 | |||||||||||||||||||||||||||||||||||||
● of the contactor with added auxiliary switch block typical | 10 000 000 | |||||||||||||||||||||||||||||||||||||
reference code according to IEC 81346-2 | Q | |||||||||||||||||||||||||||||||||||||
Substance Prohibitance (Date) | 10/01/2014 | |||||||||||||||||||||||||||||||||||||
Ambient conditions | ||||||||||||||||||||||||||||||||||||||
installation altitude at height above sea level maximum | 2 000 m | |||||||||||||||||||||||||||||||||||||
ambient temperature | ||||||||||||||||||||||||||||||||||||||
● during operation | -25 ... +60 °C | |||||||||||||||||||||||||||||||||||||
● during storage | -55 ... +80 °C | |||||||||||||||||||||||||||||||||||||
Main circuit | ||||||||||||||||||||||||||||||||||||||
number of poles for main current circuit | 3 | |||||||||||||||||||||||||||||||||||||
number of NO contacts for main contacts | 3 | |||||||||||||||||||||||||||||||||||||
number of NC contacts for main contacts | 0 | |||||||||||||||||||||||||||||||||||||
operating voltage at AC-3 rated value maximum | 690 V | |||||||||||||||||||||||||||||||||||||
operational current at AC-3 | ||||||||||||||||||||||||||||||||||||||
● at 400 V rated value | 41 A | |||||||||||||||||||||||||||||||||||||
● at 500 V rated value | 41 A | |||||||||||||||||||||||||||||||||||||
● at 690 V rated value | 24 A | |||||||||||||||||||||||||||||||||||||
operating power | ||||||||||||||||||||||||||||||||||||||
● at AC-3 | ||||||||||||||||||||||||||||||||||||||
— at 400 V rated value | 18.5 kW | |||||||||||||||||||||||||||||||||||||
— at 500 V rated value | 22 kW | |||||||||||||||||||||||||||||||||||||
— at 690 V rated value | 22 kW | |||||||||||||||||||||||||||||||||||||
● at AC-4 at 400 V rated value | 18.5 kW | |||||||||||||||||||||||||||||||||||||
operating frequency at AC-3 maximum | 1 000 1/h | |||||||||||||||||||||||||||||||||||||
Control circuit/ Control | ||||||||||||||||||||||||||||||||||||||
type of voltage of the control supply voltage | DC | |||||||||||||||||||||||||||||||||||||
control supply voltage 1 | ||||||||||||||||||||||||||||||||||||||
● at DC rated value | 24 V | |||||||||||||||||||||||||||||||||||||
design of the surge suppressor | with varistor | |||||||||||||||||||||||||||||||||||||
closing power of magnet coil at DC | 21.5 W | |||||||||||||||||||||||||||||||||||||
holding power of magnet coil at DC | 1 W | |||||||||||||||||||||||||||||||||||||
Auxiliary circuit | ||||||||||||||||||||||||||||||||||||||
number of NC contacts for auxiliary contacts | ||||||||||||||||||||||||||||||||||||||
● per direction of rotation | 0 | |||||||||||||||||||||||||||||||||||||
number of NO contacts for auxiliary contacts | ||||||||||||||||||||||||||||||||||||||
● per direction of rotation | 1 | |||||||||||||||||||||||||||||||||||||
● instantaneous contact | 2 | |||||||||||||||||||||||||||||||||||||
contact reliability of auxiliary contacts | < 1 error per 100 million operating cycles | |||||||||||||||||||||||||||||||||||||
UL/CSA ratings | ||||||||||||||||||||||||||||||||||||||
full-load current (FLA) for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||
● at 480 V rated value | 40 A | |||||||||||||||||||||||||||||||||||||
● at 600 V rated value | 41 A | |||||||||||||||||||||||||||||||||||||
yielded mechanical performance [hp] for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||
● at 220/230 V rated value | 15 hp | |||||||||||||||||||||||||||||||||||||
● at 460/480 V rated value | 30 hp | |||||||||||||||||||||||||||||||||||||
● at 575/600 V rated value | 40 hp | |||||||||||||||||||||||||||||||||||||
contact rating of auxiliary contacts according to UL | A600 / Q600 | |||||||||||||||||||||||||||||||||||||
Short-circuit protection | ||||||||||||||||||||||||||||||||||||||
design of the fuse link | ||||||||||||||||||||||||||||||||||||||
● for short-circuit protection of the main circuit | ||||||||||||||||||||||||||||||||||||||
— with type of coordination 1 required | gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 160 A | |||||||||||||||||||||||||||||||||||||
— with type of assignment 2 required | gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 80 A | |||||||||||||||||||||||||||||||||||||
● for short-circuit protection of the auxiliary switch required | fuse gG: 10 A | |||||||||||||||||||||||||||||||||||||
Installation/ mounting/ dimensions | ||||||||||||||||||||||||||||||||||||||
mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface | |||||||||||||||||||||||||||||||||||||
fastening method | screw and snap-on mounting onto 35 mm standard mounting rail | |||||||||||||||||||||||||||||||||||||
height | 141 mm | |||||||||||||||||||||||||||||||||||||
width | 120 mm | |||||||||||||||||||||||||||||||||||||
depth | 130 mm | |||||||||||||||||||||||||||||||||||||
required spacing | ||||||||||||||||||||||||||||||||||||||
● with side-by-side mounting | ||||||||||||||||||||||||||||||||||||||
— forwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
— upwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— downwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— at the side | 10 mm | |||||||||||||||||||||||||||||||||||||
● for grounded parts | ||||||||||||||||||||||||||||||||||||||
— forwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
— upwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— at the side | 10 mm | |||||||||||||||||||||||||||||||||||||
— downwards | 10 mm | |||||||||||||||||||||||||||||||||||||
● for live parts | ||||||||||||||||||||||||||||||||||||||
— forwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
— upwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— downwards | 10 mm | |||||||||||||||||||||||||||||||||||||
— at the side | 10 mm | |||||||||||||||||||||||||||||||||||||
Connections/ Terminals | ||||||||||||||||||||||||||||||||||||||
type of electrical connection | ||||||||||||||||||||||||||||||||||||||
● for main current circuit | screw-type terminals | |||||||||||||||||||||||||||||||||||||
● for auxiliary and control circuit | screw-type terminals | |||||||||||||||||||||||||||||||||||||
● at contactor for auxiliary contacts | Screw-type terminals | |||||||||||||||||||||||||||||||||||||
● of magnet coil | Screw-type terminals | |||||||||||||||||||||||||||||||||||||
type of connectable conductor cross-sections | ||||||||||||||||||||||||||||||||||||||
● for main contacts | ||||||||||||||||||||||||||||||||||||||
— solid | 2x (1 ... 35 mm²), 1x (1 ... 50 mm²) | |||||||||||||||||||||||||||||||||||||
— solid or stranded | 2x (1 ... 35 mm²), 1x (1 ... 50 mm²) | |||||||||||||||||||||||||||||||||||||
— finely stranded with core end processing | 2x (1 ... 25 mm²), 1x (1 ... 35 mm²) | |||||||||||||||||||||||||||||||||||||
● at AWG cables for main contacts | 2x (18 ... 2), 1x (18 ... 1) | |||||||||||||||||||||||||||||||||||||
type of connectable conductor cross-sections | ||||||||||||||||||||||||||||||||||||||
● for auxiliary contacts | ||||||||||||||||||||||||||||||||||||||
— solid or stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) | |||||||||||||||||||||||||||||||||||||
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) | |||||||||||||||||||||||||||||||||||||
● at AWG cables for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14) | |||||||||||||||||||||||||||||||||||||
Safety related data | ||||||||||||||||||||||||||||||||||||||
B10 value with high demand rate according to SN 31920 | 1 000 000 | |||||||||||||||||||||||||||||||||||||
proportion of dangerous failures | ||||||||||||||||||||||||||||||||||||||
● with low demand rate according to SN 31920 | 40 % | |||||||||||||||||||||||||||||||||||||
● with high demand rate according to SN 31920 | 73 % | |||||||||||||||||||||||||||||||||||||
failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT | |||||||||||||||||||||||||||||||||||||
protection class IP on the front according to IEC 60529 | IP20 | |||||||||||||||||||||||||||||||||||||
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | |||||||||||||||||||||||||||||||||||||
Communication/ Protocol | ||||||||||||||||||||||||||||||||||||||
product function bus communication | Yes | |||||||||||||||||||||||||||||||||||||
protocol is supported AS-Interface protocol | No | |||||||||||||||||||||||||||||||||||||
product function control circuit interface with IO link | No | |||||||||||||||||||||||||||||||||||||
Certificates/ approvals | ||||||||||||||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
Further information | ||||||||||||||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||||||||||||||
Characteristic: Tripping characteristics, I²t, Let-through current | ||||||||||||||||||||||||||||||||||||||
Further characteristics (e.g. electrical endurance, switching frequency) | ||||||||||||||||||||||||||||||||||||||
last modified: | 2/8/2022 | |||||||||||||||||||||||||||||||||||||
Date 5/8/2022 | Subject to change without notice © Copyright Siemens 2022 |
Product | |||||||||||||||||||||||||||||||||||||
Article Number (Market Facing Number) | 3RA2335-8XB30-1KB4 | ||||||||||||||||||||||||||||||||||||
Product Description | Reversing contactor assembly, AC-3, 18.5 kW 400 V, 0.7...1.25 US DC, 24 V DC 3-pole, Size S2 screw terminal electrical and mechanical interlock 2 NO integrated Varistor mounted | ||||||||||||||||||||||||||||||||||||
Product family | Ordering Data Overview | ||||||||||||||||||||||||||||||||||||
Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
Price data | |||||||||||||||||||||||||||||||||||||
Region Specific PriceGroup / Headquarter Price Group | 41B / 41B | ||||||||||||||||||||||||||||||||||||
Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
Metal Factor | LDO----- | ||||||||||||||||||||||||||||||||||||
Delivery information | |||||||||||||||||||||||||||||||||||||
Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
Standard lead time ex-works | On request | ||||||||||||||||||||||||||||||||||||
Net Weight (kg) | 2,777 Kg | ||||||||||||||||||||||||||||||||||||
Packaging Dimension | 247,00 x 325,00 x 237,00 | ||||||||||||||||||||||||||||||||||||
Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
Additional Product Information | |||||||||||||||||||||||||||||||||||||
EAN | 4047621019772 | ||||||||||||||||||||||||||||||||||||
UPC | 804766224560 | ||||||||||||||||||||||||||||||||||||
Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
Product Group | 5337 | ||||||||||||||||||||||||||||||||||||
Group Code | R711 | ||||||||||||||||||||||||||||||||||||
Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2014 | ||||||||||||||||||||||||||||||||||||
Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
Classifications | |||||||||||||||||||||||||||||||||||||
|
Value | Unit | |
---|---|---|
Degree of protection (NEMA) (EF011959) | - | |
Function (EF000030) | Reversing contactor | |
Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
Rated control supply voltage Us at DC (EF003980) | ['-', '24'] | V |
Voltage type for actuating (EF008242) | DC | |
Rated operation current Ie at AC-3, 400 V (EF001392) | 40 | A |
Rated operation power at AC-3, 400 V (EF001364) | 18.5 | kW |
Rated operation power NEMA (EF011960) | 22.0649625 | kW |
Type of electrical connection of main circuit (EF006819) | Screw connection | |
Degree of protection (IP) (EF005474) | IP20 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes | |
3RA2335-8XB30-1KB4 3RA2335-8XB30-1KB4 EN_3RA2335-8XB30-1KB4.pdf | 253 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.