3RA2317-8XB11-1BB4 SIEMENS REV. COMB., AC3, 5.5KW/ 400V DC24V, WITH 1NO 3-POLE, SZ S00 SCREW TERMINAL WITHO..

3RA2317-8XB11-1BB4

SIEMENS

Reversing contactor assembly AC-3, 5.5 kW/400 V, 24 V DC 3-pole, Size S00 screw terminal without NC contact interlock with 1 NO

More details


CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $156.09
Unit price: $156.09

Quantity Price
1+$156.09
2+$139.91
3+$133.32
4+$129.60
5+$128.20
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



product brand name SIRIUS
Product designation reversing contactor assembly 3RA23
Manufacturer's article number
● 1 of the supplied contactor 3RT2017-1BB41
● 2 of the supplied contactor 3RT2017-1BB41
● of the supplied RH assembly kit 3RA2913-2AA1
General technical data:
Size of contactor S00
Product extension
● Auxiliary switch Yes
Insulation voltage
● with degree of pollution 3 rated value 690 V
Degree of pollution 3
Surge voltage resistance rated value 6 kV
Protection class IP
● on the front IP20
Shock resistance 9.8g / 5 ms and 5.9g / 10 ms
● at rectangular impulse
— at AC 7,3g / 5 ms, 4,7g / 10 ms
— at DC 7.3g / 5 ms, 4.7g / 10 ms
● with sine pulse
— at AC 11,4g / 5 ms, 7,3g / 10 ms
— at DC 11,4g / 5 ms, 7,3g / 10 ms
Mechanical service life (switching cycles)
● of contactor typical 10 000 000
● of the contactor with added auxiliary switch block typical 10 000 000
Equipment marking
● acc. to DIN EN 81346-2 Q
Ambient conditions:
Installation altitude at height above sea level maximum 2 000 m
Ambient temperature
● during operation -25 ... +60 °C
● during storage -55 ... +80 °C
Main circuit:
Number of poles for main current circuit 3
Number of NO contacts for main contacts 3
Number of NC contacts for main contacts 0
Operating voltage
● at AC-3 rated value maximum 690 V
Operating current
● at AC-1 at 400 V
— at ambient temperature 40 °C rated value 22 A
— at ambient temperature 60 °C rated value 20 A
● at AC-2 at 400 V rated value 7 A
● at AC-3
— at 400 V rated value 12 A
Operating current
● at 1 current path at DC-1
— at 24 V rated value 20 A
— at 110 V rated value 2.1 A
● with 2 current paths in series at DC-1
— at 24 V rated value 20 A
— at 110 V rated value 12 A
● with 3 current paths in series at DC-1
— at 24 V rated value 20 A
— at 110 V rated value 20 A
Operating current
● at 1 current path at DC-3 at DC-5
— at 24 V rated value 20 A
— at 110 V rated value 0.15 A
● with 2 current paths in series at DC-3 at DC-5
— at 110 V rated value 0.35 A
— at 24 V rated value 20 A
● with 3 current paths in series at DC-3 at DC-5
— at 110 V rated value 20 A
— at 24 V rated value 20 A
No-load switching frequency 1 500 1/h
Operating frequency
● at AC-1 maximum 1 000 1/h
● at AC-2 maximum 750 1/h
● at AC-3 maximum 750 1/h
● at AC-4 maximum 250 1/h
Control circuit/ Control:
Type of voltage of the control supply voltage DC
Control supply voltage 1
● at DC rated value 24 V
Operating range factor control supply voltage rated value of magnet coil at DC 0.85 ... 1.1
Closing power of magnet coil at DC 4 W
Holding power of magnet coil at DC 4 W
Auxiliary circuit:
Number of NC contacts
● for auxiliary contacts
— per direction of rotation 0
— instantaneous contact 0
Number of NO contacts
● for auxiliary contacts
— per direction of rotation 1
— instantaneous contact 2
Operating current of auxiliary contacts at AC-12 maximum 10 A
Operating current of auxiliary contacts at AC-15
● at 230 V 6 A
● at 400 V 3 A
Operating current of auxiliary contacts at DC-13
● at 24 V 10 A
● at 60 V 2 A
● at 110 V 1 A
● at 220 V 0.3 A
Contact reliability of auxiliary contacts < 1 error per 100 million operating cycles
UL/CSA ratings:
Full-load current (FLA) for three-phase AC motor
● at 480 V rated value 11 A
● at 600 V rated value 11 A
Yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value 0.5 hp
— at 230 V rated value 2 hp
● for three-phase AC motor
— at 200/208 V rated value 1.5 hp
— at 220/230 V rated value 3 hp
— at 460/480 V rated value 7.5 hp
— at 575/600 V rated value 10 hp
Contact rating of auxiliary contacts according to UL A600 / Q600
Short-circuit protection
Design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 required gL/gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 50 A
— with type of assignment 2 required gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 25 A
● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A
Installation/ mounting/ dimensions:
Mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Mounting type screw and snap-on mounting onto 35 mm standard mounting rail
Height 68 mm
Width 90 mm
Depth 73 mm
Required spacing
● with side-by-side mounting
— forwards 6 mm
— Backwards 0 mm
— upwards 6 mm
— downwards 6 mm
— at the side 6 mm
● for grounded parts
— forwards 6 mm
— Backwards 0 mm
— upwards 6 mm
— at the side 6 mm
— downwards 6 mm
● for live parts
— forwards 6 mm
— Backwards 0 mm
— upwards 6 mm
— downwards 6 mm
— at the side 6 mm
Connections/Terminals:
Type of electrical connection
● for main current circuit screw-type terminals
● for auxiliary and control current circuit screw-type terminals
Type of connectable conductor cross-sections
● for main contacts
— solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
— single or multi-stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x (0,5 ... 4 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for main contacts 2x (20 ... 16), 2x (18 ... 14)
Type of connectable conductor cross-sections
● for auxiliary contacts
— single or multi-stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14)
Safety related data:
B10 value
● with high demand rate acc. to SN 31920 1 000 000
Proportion of dangerous failures
● with low demand rate acc. to SN 31920 40 %
● with high demand rate acc. to SN 31920 75 %
Failure rate [FIT]
● with low demand rate acc. to SN 31920 100 FIT
T1 value for proof test interval or service life acc. to IEC 61508 20 y
Communication/ Protocol:
Product function Bus communication No
Protocol is supported
● AS-interface protocol No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.