Load feeder fuseless, Reversing duty 400 V AC, Size S00 10.0...16.0 A 230 V AC screw terminal for 60 mm busbar systems Type of coordination 1, Iq = 150 kA 1 NC (contactor)

SIRIUS Innovations Bypass to Inverter Motor, AC 400V, S00, 11. . .16A, AC 230V screw connection 1NC fixing muddy 60mm. Manufactured to order. Non-Cancelable Non-Returnable.

More details


Low-voltage industrial components > Motor starter/Motor starter combination

CONTROL AND CONTACTORS > Contactors for switching motors

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $326.45
Unit price: $326.45

Quantity Price
1+$326.45
2+$326.46
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Technical data

Load feeder fuseless, Reversing duty 400 V AC, Size S00 10.0...16.0 A 230 V AC screw terminal for 60 mm busbar systems Type of coordination 1, Iq = 150 kA 1 NC (contactor)
product brand nameSIRIUS
product designationReversing starter
design of the productfor 60 mm busbars
product type designation3RA22
manufacturer's article number
● of the supplied contactor3RT2018-1AP02
● of the supplied circuit-breakers3RV2011-4AA10
● of the supplied RS assembly kit8US1250-5AS10
● of the supplied busbar adapter8US1251-5DS10
● of the supplied link module3RA1921-1DA00
General technical data
size of the circuit-breakerS00
size of load feederS00
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
degree of protection NEMA ratingother
shock resistance according to IEC 60068-2-276g / 11 ms
mechanical service life (switching cycles) of contactor typical30 000 000
type of assignment1
type of protection according to ATEX directive 2014/34/EUEx II (2) GD
certificate of suitability according to ATEX directive 2014/34/EUDMT 02 ATEX F 001
Substance Prohibitance (Date)10/01/2009
Ambient conditions
ambient temperature
● during operation-20 ... +60 °C
● during storage-50 ... +80 °C
● during transport-50 ... +80 °C
temperature compensation-20 ... +60 °C
relative humidity during operation10 ... 95 %
Main circuit
number of poles for main current circuit3
design of the switching contactelectromechanical
adjustable current response value current of the current-dependent overload release10 ... 16 A
operating voltage
● rated value690 V
● at AC-3 rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current at AC-3 at 400 V rated value15.5 A
operating power at AC-3
● at 400 V rated value7 500 W
Control circuit/ Control
type of voltage of the control supply voltageAC
control supply voltage at AC
● at 50 Hz rated value230 V
● at 50 Hz rated value230 ... 230 V
● at 60 Hz rated value230 V
● at 60 Hz rated value230 ... 230 V
apparent holding power of magnet coil at AC5.7 VA
Auxiliary circuit
product extension auxiliary switchYes
Protective and monitoring functions
trip classCLASS 10
design of the overload releasethermal (bimetallic)
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value14 A
yielded mechanical performance [hp]
● for 3-phase AC motor
— at 220/230 V rated value5 hp
— at 460/480 V rated value10 hp
— at 575/600 V rated value10 hp
Short-circuit protection
product function short circuit protectionYes
design of the short-circuit tripmagnetic
conditional short-circuit current (Iq)
● at 400 V according to IEC 60947-4-1 rated value150 000 A
Installation/ mounting/ dimensions
mounting positionvertical
fastening methodfor snapping onto 60 mm busbar systems
height200 mm
width90 mm
depth156 mm
required spacing
● for grounded parts
— forwards32 mm
— backwards0 mm
— upwards50 mm
— at the side10 mm
— downwards10 mm
● for live parts
— forwards32 mm
— backwards0 mm
— upwards50 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
type of electrical connection
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
Safety related data
B10 value with high demand rate according to SN 319201 000 000
proportion of dangerous failures
● with high demand rate according to SN 3192073 %
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Communication/ Protocol
protocol is supported
● PROFINET IO protocolNo
● PROFIsafe protocolNo
protocol is supported AS-Interface protocolNo
Certificates/ approvals

Downloads and manuals

General Product ApprovalFor use in hazardous locationsDeclaration of Conformity

CSA

Confirmation

UL

EAC

ATEX-EC-Type-Examination-Certificate

EC/EU-Declaration of Conformity

Declaration of ConformityTest CertificatesMarine / Shipping

UK Declaration of Conformity

Type Test Certificates/Test Report

Special Test Certificate

ABS (American Bureau of Shipping)

BV / Bureau Veritas

LR (Lloyds Register)

Marine / ShippingotherRailway

PRS / Polski Rejestr Statkow

RINA / Registro Italiano Navale

RMRS / Russian Maritime Register

DNV-GL

Confirmation

Vibration and Shock

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:2/16/2022
Date
5/14/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RA2210-4AD18-2AP0
Product DescriptionLoad feeder fuseless, Reversing duty 400 V AC, Size S00 10.0...16.0 A 230 V AC screw terminal for 60 mm busbar systems Type of coordination 1, Iq = 150 kA 1 NC (contactor)
Product familySIRIUS 3RA2 load feeders
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41D / 41D
Surcharge for Raw MaterialsNone
Metal FactorLCO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works20 Day/Days
Net Weight (kg)1,740 Kg
Packaging Dimension246,00 x 326,00 x 222,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209798366
UPC662643902112
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5348
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-09-05
eClass7.127-37-09-05
eClass827-37-09-05
eClass927-37-09-05
eClass9.127-37-09-05
ETIM5EC001037
ETIM6EC001037
ETIM7EC001037
ETIM8EC001037
IDEA44741
UNSPSC1439-12-15-21
UNSPSC1539-12-15-21

ETIM data

ETIM: EC001037 - Motor starter/Motor starter combination

Value Unit
Rated power, 460 V, 60 Hz, 3-phase (EF009600) -kW
Supporting protocol for PROFIsafe (EF007526) -
Rail mounting possible (EF003972) -
Supporting protocol for DeviceNet (EF003059) -
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) -A
Rated operation power at AC-3, 230 V, 3-phase (EF009599) -kW
Supporting protocol for Foundation Fieldbus (EF007522) -
Supporting protocol for SUCONET (EF003060) -
Suitable for emergency stop (EF001433) -
Degree of protection (NEMA) (EF011959) -
Ambient temperature, upper operating limit (EF009603) -°C
External reset possible (EF003426) -
Supporting protocol for Data-Highway (EF003058) -
Supporting protocol for CAN (EF003053) -
Supporting protocol for LON (EF003017) -
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) -A
Supporting protocol for PROFINET IO (EF007525) -
Supporting protocol for DeviceNet Safety (EF007520) -
Supporting protocol for other bus systems (EF003062) -
Supporting protocol for INTERBUS (EF003054) -
Supporting protocol for PROFIBUS (EF003052) -
Temperature compensated overload protection (EF009604) -
Supporting protocol for Modbus (EF003057) -
Supporting protocol for EtherNet/IP (EF007521) -
Type of electrical connection for auxiliary- and control current circuit (EF006979) -
Supporting protocol for SERCOS (EF006657) -
Rated power, 575 V, 60 Hz, 3-phase (EF009601) -kW
Rated conditional short-circuit current, type 2, 230 V (EF009606) -A
Supporting protocol for ASI (EF003051) -
Supporting protocol for INTERBUS-Safety (EF006662) -
Supporting protocol for SafetyBUS p (EF007527) -
Rated conditional short-circuit current, type 2, 400 V (EF009605) -A
Supporting protocol for AS-Interface Safety at Work (EF007519) -
Supporting protocol for TCP/IP (EF003050) -
Supporting protocol for PROFINET CBA (EF007524) -
Number of command positions (EF001372) -
Type of motor starter (EF009598) Other
With short-circuit release (EF006691) true
Rated control supply voltage Us at DC (EF003980) ['-', '-']V
Voltage type for actuating (EF008242) AC / AC
Rated operation power at AC-3, 400 V (EF001364) 7.5kW
Rated operation current Ie (EF001443) 15.5A
Rated operation current at AC-3, 400 V (EF009602) 15.5A
Overload release current setting (EF002336) ['10', '16']A
Number of auxiliary contacts as normally open contact (EF001376) -
Number of auxiliary contacts as normally closed contact (EF001377) -
Release class (EF006668) CLASS 10
Type of electrical connection of main circuit (EF006819) Screw connection
With transformer (EF000278) false
Coordination class according to IEC 60947-4-3 (EF012390) Class 1
Number of indicator lights (EF001965) 0
With fuse (EF006693) false
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 90.0mm
Height (EF000040) 200.0mm
Depth (EF000049) 156.0mm
Rated control supply voltage Us at AC 50HZ (EF003978) -V
Rated control supply voltage Us at AC 60HZ (EF003979) -V


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.