Product successfully added to your shopping cart
3RA2210-1AH15-2AP0
SIEMENS
1
Load feeder fuseless, Reversing duty 400 V AC, Size S00 1.10...1.60 A 230 V AC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor)
SIRIUS Innovations Bypass to Inverter Motor, AC 400V, S00, 1, 1. . .1, 6A, AC 230V spring connection 1NC fixing muddy 60mm. Manufactured to order. Non-Cancelable Non-Returnable.
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > Contactors for switching motors
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product | ||||||||||||||||||||||||||||||||||||||||
Article Number (Market Facing Number) | 3RA2210-1AH15-2AP0 | |||||||||||||||||||||||||||||||||||||||
Product Description | Load feeder fuseless, Reversing duty 400 V AC, Size S00 1.10...1.60 A 230 V AC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor) | |||||||||||||||||||||||||||||||||||||||
Product family | SIRIUS 3RA2 load feeders | |||||||||||||||||||||||||||||||||||||||
Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
Price data | ||||||||||||||||||||||||||||||||||||||||
Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | |||||||||||||||||||||||||||||||||||||||
Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
Metal Factor | LCO----- | |||||||||||||||||||||||||||||||||||||||
Delivery information | ||||||||||||||||||||||||||||||||||||||||
Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
Standard lead time ex-works | 20 Day/Days | |||||||||||||||||||||||||||||||||||||||
Net Weight (kg) | 1,854 Kg | |||||||||||||||||||||||||||||||||||||||
Packaging Dimension | 246,00 x 326,00 x 222,00 | |||||||||||||||||||||||||||||||||||||||
Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
EAN | 4011209797710 | |||||||||||||||||||||||||||||||||||||||
UPC | 662643901351 | |||||||||||||||||||||||||||||||||||||||
Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
Product Group | 5348 | |||||||||||||||||||||||||||||||||||||||
Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | |||||||||||||||||||||||||||||||||||||||
Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
Classifications | ||||||||||||||||||||||||||||||||||||||||
|
Value | Unit | |
---|---|---|
Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
Supporting protocol for EtherNet/IP (EF007521) | - | |
Supporting protocol for DeviceNet (EF003059) | - | |
Supporting protocol for ASI (EF003051) | - | |
Temperature compensated overload protection (EF009604) | - | |
Supporting protocol for PROFIsafe (EF007526) | - | |
Rail mounting possible (EF003972) | - | |
Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
Supporting protocol for DeviceNet Safety (EF007520) | - | |
Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
Supporting protocol for CAN (EF003053) | - | |
Supporting protocol for LON (EF003017) | - | |
Supporting protocol for Modbus (EF003057) | - | |
Supporting protocol for SafetyBUS p (EF007527) | - | |
Supporting protocol for PROFINET CBA (EF007524) | - | |
Supporting protocol for SERCOS (EF006657) | - | |
External reset possible (EF003426) | - | |
Supporting protocol for Data-Highway (EF003058) | - | |
Supporting protocol for INTERBUS (EF003054) | - | |
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
Ambient temperature, upper operating limit (EF009603) | - | °C |
Supporting protocol for PROFINET IO (EF007525) | - | |
Supporting protocol for TCP/IP (EF003050) | - | |
Supporting protocol for SUCONET (EF003060) | - | |
Supporting protocol for INTERBUS-Safety (EF006662) | - | |
Supporting protocol for Foundation Fieldbus (EF007522) | - | |
Degree of protection (NEMA) (EF011959) | - | |
Suitable for emergency stop (EF001433) | - | |
Supporting protocol for PROFIBUS (EF003052) | - | |
Number of command positions (EF001372) | - | |
Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
Supporting protocol for other bus systems (EF003062) | - | |
Type of motor starter (EF009598) | Other | |
With short-circuit release (EF006691) | true | |
Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
Voltage type for actuating (EF008242) | AC / AC | |
Rated operation power at AC-3, 400 V (EF001364) | 0.55 | kW |
Rated operation current Ie (EF001443) | 1.5 | A |
Rated operation current at AC-3, 400 V (EF009602) | 1.5 | A |
Overload release current setting (EF002336) | ['1.1', '1.6'] | A |
Number of auxiliary contacts as normally open contact (EF001376) | - | |
Number of auxiliary contacts as normally closed contact (EF001377) | - | |
Release class (EF006668) | CLASS 10 | |
Type of electrical connection of main circuit (EF006819) | Spring clamp connection | |
With transformer (EF000278) | false | |
Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
Number of indicator lights (EF001965) | 0 | |
With fuse (EF006693) | false | |
Degree of protection (IP) (EF005474) | IP20 | |
Width (EF000008) | 90.0 | mm |
Height (EF000040) | 260.0 | mm |
Depth (EF000049) | 155.0 | mm |
Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes | |
3RA2210-1AH15-2AP0 3RA2210-1AH15-2AP0 EN_3RA2210-1AH15-2AP0.pdf | 339 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.