Product successfully added to your shopping cart
3RA2120-1GD24-0FB4
SIEMENS
1
Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 4.50...6.30 A 24 V DC screw terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO+1 NC (contactor) with diode combination plugged in at the front
DERIVAC. A MOTOR WITHOUT FUSES ARRAN. DIR.,AC 400V,TAM. S0 4,50...6,30A 5,5KW,5,5KW,24 V DC SCREW TERMINALS FOR 60MM BUSBARS (ALSO COMPLIES TYPE COORD. 1) TYPE OF COORD. 2,IQ = 150KA 1NA+1NC (CONTACTOR) WITH DIODE COMBINATION PLUGGED IN FRONT. Manufactured to order. Non-Cancelable Non-Returnable.
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > Contactors for switching motors
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 4.50...6.30 A 24 V DC screw terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO+1 NC (contactor) with diode combination plugged in at the front | ||||||||||||||||||||||||||||||||||||||||||||||||||
product brand name | SIRIUS | |||||||||||||||||||||||||||||||||||||||||||||||||
product designation | Direct (on-line) starter | |||||||||||||||||||||||||||||||||||||||||||||||||
design of the product | for 60 mm busbars | |||||||||||||||||||||||||||||||||||||||||||||||||
product type designation | 3RA21 | |||||||||||||||||||||||||||||||||||||||||||||||||
manufacturer's article number | ||||||||||||||||||||||||||||||||||||||||||||||||||
● of the supplied contactor | 3RT2024-1FB40 | |||||||||||||||||||||||||||||||||||||||||||||||||
● of the supplied circuit-breakers | 3RV2011-1GA10 | |||||||||||||||||||||||||||||||||||||||||||||||||
● of the supplied busbar adapter | 8US1251-5NT10 | |||||||||||||||||||||||||||||||||||||||||||||||||
● of the supplied link module | 3RA2921-1BA00 | |||||||||||||||||||||||||||||||||||||||||||||||||
General technical data | ||||||||||||||||||||||||||||||||||||||||||||||||||
size of the circuit-breaker | S00 | |||||||||||||||||||||||||||||||||||||||||||||||||
size of load feeder | S0 | |||||||||||||||||||||||||||||||||||||||||||||||||
insulation voltage with degree of pollution 3 at AC rated value | 690 V | |||||||||||||||||||||||||||||||||||||||||||||||||
surge voltage resistance rated value | 6 kV | |||||||||||||||||||||||||||||||||||||||||||||||||
degree of protection NEMA rating | other | |||||||||||||||||||||||||||||||||||||||||||||||||
shock resistance according to IEC 60068-2-27 | 6g / 11 ms | |||||||||||||||||||||||||||||||||||||||||||||||||
mechanical service life (switching cycles) of contactor typical | 10 000 000 | |||||||||||||||||||||||||||||||||||||||||||||||||
type of assignment | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||
type of protection according to ATEX directive 2014/34/EU | Ex II (2) GD | |||||||||||||||||||||||||||||||||||||||||||||||||
certificate of suitability according to ATEX directive 2014/34/EU | DMT 02 ATEX F 001 | |||||||||||||||||||||||||||||||||||||||||||||||||
Ambient conditions | ||||||||||||||||||||||||||||||||||||||||||||||||||
ambient temperature | ||||||||||||||||||||||||||||||||||||||||||||||||||
● during operation | -20 ... +60 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
● during storage | -50 ... +80 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
● during transport | -50 ... +80 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
temperature compensation | -20 ... +60 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
relative humidity during operation | 10 ... 95 % | |||||||||||||||||||||||||||||||||||||||||||||||||
Main circuit | ||||||||||||||||||||||||||||||||||||||||||||||||||
number of poles for main current circuit | 3 | |||||||||||||||||||||||||||||||||||||||||||||||||
design of the switching contact | electromechanical | |||||||||||||||||||||||||||||||||||||||||||||||||
adjustable current response value current of the current-dependent overload release | 4.5 ... 6.3 A | |||||||||||||||||||||||||||||||||||||||||||||||||
operating voltage | ||||||||||||||||||||||||||||||||||||||||||||||||||
● rated value | 690 V | |||||||||||||||||||||||||||||||||||||||||||||||||
● at AC-3 rated value maximum | 690 V | |||||||||||||||||||||||||||||||||||||||||||||||||
operating frequency rated value | 50 ... 60 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||
operational current at AC-3 at 400 V rated value | 4.9 A | |||||||||||||||||||||||||||||||||||||||||||||||||
operating power at AC-3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
● at 400 V rated value | 2 200 W | |||||||||||||||||||||||||||||||||||||||||||||||||
Control circuit/ Control | ||||||||||||||||||||||||||||||||||||||||||||||||||
type of voltage of the control supply voltage | DC | |||||||||||||||||||||||||||||||||||||||||||||||||
control supply voltage at DC | ||||||||||||||||||||||||||||||||||||||||||||||||||
● rated value | 24 V | |||||||||||||||||||||||||||||||||||||||||||||||||
● rated value | 24 ... 24 V | |||||||||||||||||||||||||||||||||||||||||||||||||
holding power of magnet coil at DC | 5.9 W | |||||||||||||||||||||||||||||||||||||||||||||||||
Auxiliary circuit | ||||||||||||||||||||||||||||||||||||||||||||||||||
product extension auxiliary switch | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||
Protective and monitoring functions | ||||||||||||||||||||||||||||||||||||||||||||||||||
trip class | CLASS 10 | |||||||||||||||||||||||||||||||||||||||||||||||||
design of the overload release | thermal (bimetallic) | |||||||||||||||||||||||||||||||||||||||||||||||||
UL/CSA ratings | ||||||||||||||||||||||||||||||||||||||||||||||||||
full-load current (FLA) for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||||||||||||||
● at 480 V rated value | 4.8 A | |||||||||||||||||||||||||||||||||||||||||||||||||
yielded mechanical performance [hp] | ||||||||||||||||||||||||||||||||||||||||||||||||||
● for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||||||||||||||
— at 200/208 V rated value | 1 hp | |||||||||||||||||||||||||||||||||||||||||||||||||
— at 220/230 V rated value | 1.5 hp | |||||||||||||||||||||||||||||||||||||||||||||||||
— at 460/480 V rated value | 3 hp | |||||||||||||||||||||||||||||||||||||||||||||||||
— at 575/600 V rated value | 5 hp | |||||||||||||||||||||||||||||||||||||||||||||||||
Short-circuit protection | ||||||||||||||||||||||||||||||||||||||||||||||||||
product function short circuit protection | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||
design of the short-circuit trip | magnetic | |||||||||||||||||||||||||||||||||||||||||||||||||
conditional short-circuit current (Iq) | ||||||||||||||||||||||||||||||||||||||||||||||||||
● at 400 V according to IEC 60947-4-1 rated value | 150 000 A | |||||||||||||||||||||||||||||||||||||||||||||||||
Installation/ mounting/ dimensions | ||||||||||||||||||||||||||||||||||||||||||||||||||
mounting position | vertical | |||||||||||||||||||||||||||||||||||||||||||||||||
fastening method | for snapping onto 60 mm busbar systems | |||||||||||||||||||||||||||||||||||||||||||||||||
height | 260 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
width | 45 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
depth | 165 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
required spacing | ||||||||||||||||||||||||||||||||||||||||||||||||||
● for grounded parts | ||||||||||||||||||||||||||||||||||||||||||||||||||
— forwards | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— backwards | 0 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— upwards | 50 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— at the side | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— downwards | 10 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
● for live parts | ||||||||||||||||||||||||||||||||||||||||||||||||||
— forwards | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— backwards | 0 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— upwards | 50 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— downwards | 10 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
— at the side | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
Connections/ Terminals | ||||||||||||||||||||||||||||||||||||||||||||||||||
type of electrical connection | ||||||||||||||||||||||||||||||||||||||||||||||||||
● for main current circuit | screw-type terminals | |||||||||||||||||||||||||||||||||||||||||||||||||
● for auxiliary and control circuit | screw-type terminals | |||||||||||||||||||||||||||||||||||||||||||||||||
Safety related data | ||||||||||||||||||||||||||||||||||||||||||||||||||
B10 value with high demand rate according to SN 31920 | 1 000 000 | |||||||||||||||||||||||||||||||||||||||||||||||||
proportion of dangerous failures | ||||||||||||||||||||||||||||||||||||||||||||||||||
● with high demand rate according to SN 31920 | 73 % | |||||||||||||||||||||||||||||||||||||||||||||||||
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | |||||||||||||||||||||||||||||||||||||||||||||||||
Communication/ Protocol | ||||||||||||||||||||||||||||||||||||||||||||||||||
protocol is supported | ||||||||||||||||||||||||||||||||||||||||||||||||||
● PROFINET IO protocol | No | |||||||||||||||||||||||||||||||||||||||||||||||||
● PROFIsafe protocol | No | |||||||||||||||||||||||||||||||||||||||||||||||||
protocol is supported AS-Interface protocol | No | |||||||||||||||||||||||||||||||||||||||||||||||||
Certificates/ approvals | ||||||||||||||||||||||||||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Further information | ||||||||||||||||||||||||||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Characteristic: Tripping characteristics, I²t, Let-through current | ||||||||||||||||||||||||||||||||||||||||||||||||||
Further characteristics (e.g. electrical endurance, switching frequency) | ||||||||||||||||||||||||||||||||||||||||||||||||||
last modified: | 2/16/2022 | |||||||||||||||||||||||||||||||||||||||||||||||||
Date 5/14/2022 | Subject to change without notice © Copyright Siemens 2022 |
Product | |||||||||||||||||||||||||||||||||||||
Article Number (Market Facing Number) | 3RA2120-1GD24-0FB4 | ||||||||||||||||||||||||||||||||||||
Product Description | Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 4.50...6.30 A 24 V DC screw terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO+1 NC (contactor) with diode combination plugged in at the front | ||||||||||||||||||||||||||||||||||||
Product family | SIRIUS 3RA2 load feeders | ||||||||||||||||||||||||||||||||||||
Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
Price data | |||||||||||||||||||||||||||||||||||||
Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | ||||||||||||||||||||||||||||||||||||
Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
Metal Factor | LCO----- | ||||||||||||||||||||||||||||||||||||
Delivery information | |||||||||||||||||||||||||||||||||||||
Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
Standard lead time ex-works | 200 Day/Days | ||||||||||||||||||||||||||||||||||||
Net Weight (kg) | 1,447 Kg | ||||||||||||||||||||||||||||||||||||
Packaging Dimension | 221,00 x 306,00 x 87,00 | ||||||||||||||||||||||||||||||||||||
Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
Additional Product Information | |||||||||||||||||||||||||||||||||||||
EAN | 4011209933842 | ||||||||||||||||||||||||||||||||||||
UPC | Not available | ||||||||||||||||||||||||||||||||||||
Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
Product Group | 5348 | ||||||||||||||||||||||||||||||||||||
Group Code | R711 | ||||||||||||||||||||||||||||||||||||
Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
Compliance with the substance restrictions according to RoHS directive | not available | ||||||||||||||||||||||||||||||||||||
Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
Classifications | |||||||||||||||||||||||||||||||||||||
|
Value | Unit | |
---|---|---|
Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
Supporting protocol for PROFIsafe (EF007526) | - | |
Supporting protocol for SERCOS (EF006657) | - | |
External reset possible (EF003426) | - | |
Number of command positions (EF001372) | - | |
Degree of protection (NEMA) (EF011959) | - | |
Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
Supporting protocol for DeviceNet Safety (EF007520) | - | |
Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
Supporting protocol for other bus systems (EF003062) | - | |
Supporting protocol for INTERBUS (EF003054) | - | |
Supporting protocol for TCP/IP (EF003050) | - | |
Supporting protocol for LON (EF003017) | - | |
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
Supporting protocol for SafetyBUS p (EF007527) | - | |
Supporting protocol for EtherNet/IP (EF007521) | - | |
Supporting protocol for INTERBUS-Safety (EF006662) | - | |
Supporting protocol for PROFIBUS (EF003052) | - | |
Supporting protocol for Data-Highway (EF003058) | - | |
Supporting protocol for CAN (EF003053) | - | |
Suitable for emergency stop (EF001433) | - | |
Ambient temperature, upper operating limit (EF009603) | - | °C |
Supporting protocol for ASI (EF003051) | - | |
Supporting protocol for DeviceNet (EF003059) | - | |
Supporting protocol for Foundation Fieldbus (EF007522) | - | |
Supporting protocol for PROFINET IO (EF007525) | - | |
Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
Supporting protocol for Modbus (EF003057) | - | |
Temperature compensated overload protection (EF009604) | - | |
Supporting protocol for SUCONET (EF003060) | - | |
Rail mounting possible (EF003972) | - | |
Supporting protocol for PROFINET CBA (EF007524) | - | |
Type of motor starter (EF009598) | Other | |
With short-circuit release (EF006691) | true | |
Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
Voltage type for actuating (EF008242) | DC / DC | |
Rated operation power at AC-3, 400 V (EF001364) | 2.2 | kW |
Rated operation current Ie (EF001443) | 4.9 | A |
Rated operation current at AC-3, 400 V (EF009602) | 4.9 | A |
Overload release current setting (EF002336) | ['4.5', '6.3'] | A |
Number of auxiliary contacts as normally open contact (EF001376) | - | |
Number of auxiliary contacts as normally closed contact (EF001377) | - | |
Release class (EF006668) | CLASS 10 | |
Type of electrical connection of main circuit (EF006819) | Screw connection | |
With transformer (EF000278) | false | |
Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
Number of indicator lights (EF001965) | 0 | |
With fuse (EF006693) | false | |
Degree of protection (IP) (EF005474) | IP20 | |
Width (EF000008) | 45.0 | mm |
Height (EF000040) | 260.0 | mm |
Depth (EF000049) | 165.0 | mm |
Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes | |
3RA2120-1GD24-0FB4 3RA2120-1GD24-0FB4 EN_3RA2120-1GD24-0FB4.pdf | 302 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.