General technical data: | |||||||||||||||||||||||||||
product brand name | SIRIUS | ||||||||||||||||||||||||||
Product designation | contactor assembly | ||||||||||||||||||||||||||
Product function | wye-delta-contactor | ||||||||||||||||||||||||||
Size of contactor | S3, S3, S2 | ||||||||||||||||||||||||||
Protection class IP on the front | IP20 | ||||||||||||||||||||||||||
Degree of pollution | 3 | ||||||||||||||||||||||||||
Insulation voltage with degree of pollution 3 rated value | V | 690 | |||||||||||||||||||||||||
Installation altitude at height above sea level maximum | m | 2 000 | |||||||||||||||||||||||||
Ambient temperature | |||||||||||||||||||||||||||
● during operation | °C | -25 ... +60 | |||||||||||||||||||||||||
● during storage | °C | -55 ... +80 | |||||||||||||||||||||||||
● during transport | °C | -55 ... +80 | |||||||||||||||||||||||||
Equipment marking acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | K | ||||||||||||||||||||||||||
Equipment marking acc. to DIN EN 61346-2 | Q | ||||||||||||||||||||||||||
Mechanical service life (switching cycles) | |||||||||||||||||||||||||||
● of the main contacts typical | 10 000 000 | ||||||||||||||||||||||||||
● of auxiliary contacts typical | 10 000 000 | ||||||||||||||||||||||||||
● of the contactor with added auxiliary switch block typical | 10 000 000 | ||||||||||||||||||||||||||
Main circuit: | |||||||||||||||||||||||||||
Number of poles for main current circuit | 3 | ||||||||||||||||||||||||||
Number of NC contacts for main contacts | 0 | ||||||||||||||||||||||||||
Operating voltage at AC-3 rated value maximum | V | 690 | |||||||||||||||||||||||||
Operating current at AC-3 at 400 V rated value | A | 150 | |||||||||||||||||||||||||
Operating power at AC-3 | |||||||||||||||||||||||||||
● at 400 V rated value | kW | 75 | |||||||||||||||||||||||||
● at 500 V rated value | kW | 103 | |||||||||||||||||||||||||
● at 690 V rated value | kW | 110 | |||||||||||||||||||||||||
Control circuit/ Control: | |||||||||||||||||||||||||||
Control version of the switch operating mechanism | conventional | ||||||||||||||||||||||||||
Design of the surge suppressor | without | ||||||||||||||||||||||||||
Type of voltage of the control supply voltage | AC | ||||||||||||||||||||||||||
Control supply voltage frequency | |||||||||||||||||||||||||||
● 1 rated value | Hz | 50 | |||||||||||||||||||||||||
Control supply voltage 1 | |||||||||||||||||||||||||||
● at AC | |||||||||||||||||||||||||||
— at 50 Hz rated value | V | 24 | |||||||||||||||||||||||||
Operating range factor control supply voltage rated value of magnet coil | |||||||||||||||||||||||||||
● at AC | |||||||||||||||||||||||||||
— at 50 Hz | 0.8 ... 1.1 | ||||||||||||||||||||||||||
— at 60 Hz | 0.85 ... 1.1 | ||||||||||||||||||||||||||
● at DC | 0.8 ... 1.1 | ||||||||||||||||||||||||||
Auxiliary circuit: | |||||||||||||||||||||||||||
Product extension Auxiliary switch | Yes | ||||||||||||||||||||||||||
Number of NC contacts for auxiliary contacts | |||||||||||||||||||||||||||
● lagging switching | 0 | ||||||||||||||||||||||||||
Number of NO contacts for auxiliary contacts | |||||||||||||||||||||||||||
● leading contact | 0 | ||||||||||||||||||||||||||
Short-circuit: | |||||||||||||||||||||||||||
Design of the fuse link | |||||||||||||||||||||||||||
● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A | ||||||||||||||||||||||||||
● for short-circuit protection of the main circuit | |||||||||||||||||||||||||||
— with type of coordination 1 required | fuse gL/gG: 250 A | ||||||||||||||||||||||||||
— with type of assignment 2 required | fuse gL/gG: 160 A | ||||||||||||||||||||||||||
Installation/ mounting/ dimensions: | |||||||||||||||||||||||||||
Mounting position | with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back | ||||||||||||||||||||||||||
Mounting type | screw fixing | ||||||||||||||||||||||||||
Width | mm | 218 | |||||||||||||||||||||||||
Height | mm | 180 | |||||||||||||||||||||||||
Depth | mm | 194 | |||||||||||||||||||||||||
Required spacing | |||||||||||||||||||||||||||
● with side-by-side mounting at the side | mm | 0 | |||||||||||||||||||||||||
● for grounded parts at the side | mm | 0 | |||||||||||||||||||||||||
● for live parts | |||||||||||||||||||||||||||
— at the side | mm | 0 | |||||||||||||||||||||||||
Connections/ Terminals: | |||||||||||||||||||||||||||
Type of electrical connection for main current circuit | screw-type terminals | ||||||||||||||||||||||||||
Certificates/ approvals: | |||||||||||||||||||||||||||
Certificate of suitability | CE / UL / CCC / GL / LRS / BV / DNV / RMRS / RINA / PRS / ABS | ||||||||||||||||||||||||||
| |||||||||||||||||||||||||||
Safety related data: | |||||||||||||||||||||||||||
Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG SIEMENS SIRIUS INDUSTRIAL CONTROLS EN.pdf | 279 Mbytes | |
3RA1445-8XB20-1AB0 SIEMENS CONTACTOR COMBINATION, STAR-DELTA (FACTORY-ASSEMBLED) WITH FRONT SIDE TIMING R | 84 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.