Product successfully added to your shopping cart
3RA1135-4FB35-0EL2
SIEMENS
1
LOAD FEEDER FUSE LINE DIRECT START, 400 V AC, SIZE S2 28...40 A, 230 V AC, 50 HZ, SCREW CONNECTION 1NO+1NC (CIRCUIT-BREAKER) FOR SCREW AND SNAP FIXING ASSIGN. TYPE 2, IQ = 50 KA (COMPLY ALSO ASSIGN. TYPE 1)
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > Contactors for switching motors
* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
product brand name | SIRIUS | |
Product designation | non-fused load feeder | |
Design of the product | direct starter | |
Manufacturer's article number | ||
● of the supplied contactor | 3RT1035-1AL20 | |
● of the supplied circuit-breakers | 3RV1031-4FA10 | |
● of the supplied link module | 3RA1931-1AA00 | |
● of the supplied standard mounting rail adapter | 3RA1932-1AA00 | |
General technical data: | ||
Size of load feeder | S2 | |
Insulation voltage | ||
● rated value | 690 V | |
Degree of pollution | 3 | |
Surge voltage resistance rated value | 6 kV | |
Protection class IP | ||
● on the front | IP20 | |
Shock resistance | 8g | |
Mechanical service life (switching cycles) | ||
● of contactor typical | 10 000 000 | |
Type of assignment | 2 | |
Equipment marking | ||
● acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | Q | |
● acc. to DIN EN 61346-2 | Q | |
● acc. to DIN EN 81346-2 | Q | |
Ambient conditions: | ||
Installation altitude at height above sea level maximum | 2 000 m | |
Ambient temperature | ||
● during operation | -20 ... +70 °C | |
● during storage | -55 ... +80 °C | |
Main circuit: | ||
Number of poles for main current circuit | 3 | |
Design of the switching contact | electromechanical | |
Adjustable pick-up value current of the current-dependent overload release | 28 ... 40 A | |
Type of the motor protection | bimetal | |
Operating voltage | ||
● at AC-3 rated value maximum | 400 V | |
Operating current | ||
● at AC-3 | ||
— at 400 V rated value | 35 A | |
Operating power | ||
● at AC-3 | ||
— at 400 V rated value | 18.5 kW | |
No-load switching frequency | 15 1/s | |
Control circuit/ Control: | ||
Type of voltage of the control supply voltage | AC | |
Control supply voltage 1 at AC | ||
● at 50 Hz rated value | 230 V | |
● at 60 Hz rated value | 230 V | |
Control supply voltage frequency 1 | 50 ... 60 Hz | |
Auxiliary circuit: | ||
Product extension Auxiliary switch | Yes | |
Number of NC contacts | ||
● for auxiliary contacts | 1 | |
Number of NO contacts | ||
● for auxiliary contacts | 1 | |
Number of CO contacts | ||
● for auxiliary contacts | 0 | |
Protective and monitoring functions: | ||
Maximum short-circuit current breaking capacity (Icu) | ||
● at 400 V rated value | 50 kA | |
Short-circuit protection | ||
Product function | ||
● Short circuit protection | Yes | |
Design of short-circuit protection | circuit-breakers | |
Installation/ mounting/ dimensions: | ||
Mounting position | with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back | |
Mounting type | snap-on mounting | |
Height | 295 mm | |
Width | 55 mm | |
Depth | 173 mm | |
Required spacing | ||
● with side-by-side mounting | ||
— at the side | 0 mm | |
● for grounded parts | ||
— forwards | 10 mm | |
— Backwards | 0 mm | |
— upwards | 50 mm | |
— at the side | 10 mm | |
● for live parts | ||
— forwards | 10 mm | |
— Backwards | 10 mm | |
— downwards | 0 mm | |
— at the side | 50 mm | |
Connections/Terminals: | ||
Type of electrical connection | ||
● for main current circuit | screw-type terminals | |
Type of connectable conductor cross-sections | ||
● for main contacts | ||
— solid | 0.7 ... 35 mm², 2x (0.75 ... 25 mm²) | |
— stranded | 0.7 ... 35 mm², 2x (0.75 ... 25 mm²) | |
— finely stranded with core end processing | 0.75 ... 25 mm², 2x (0.75 ... 16 mm²) | |
● at AWG conductors for main contacts | 2x (30 ... 2) | |
Connectable conductor cross-section for main contacts | ||
● single or multi-stranded | 0.7 ... 35 mm² | |
● finely stranded with core end processing | 0.75 ... 25 mm² | |
AWG number as coded connectable conductor cross section | ||
● for main contacts | 30 ... 2 | |
Communication/ Protocol: | ||
Product function Bus communication | No | |
Protocol | ||
● is supported PROFIBUS DP protocol | No | |
● is supported PROFINET protocol | No | |
Protocol is supported | ||
● AS-interface protocol | No | |
Inputs/ Outputs: | ||
Number of digital inputs | 0 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes | |
3RA1135-4FB35-0EL2 SIEMENS LOAD FEEDER FUSE LINE DIRECT START, 400 V AC, SIZE S2 28...40 A, 230 V AC, 50 | 65 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.