3LD2210-0TK00-0AF1 SIEMENS SENTRON, Switch disconnector 3LD, breaker, 3-pole, Iu: 32 A, Operating power / at.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3LD2210-0TK00-0AF1 SIEMENS SENTRON, Switch disconnector 3LD, breaker, 3-pole, Iu: 32 A, Operating power / at..

3LD2210-0TK00-0AF1

SIEMENS

100

SENTRON, Switch disconnector 3LD, breaker, 3-pole, Iu: 32 A, Operating power / at AC- 23 A at 400 V: 11.5 kW, floor mounting with door coupling, without

INTERR. MAIN 3 POLES IU=32,P/AC23-A WITH 400V=11,A P/AC23-B AT 400V=15KW FIXING BASED FIXATION TO PROFILE/TWO HOLES ***SPECIAL VERSION*** ***MODIFIED DRIVE*** ( ** ATTENTION: Price per 1 Unit and Minimum Quantity / Order Multiple 100 Units ** ). Manufactured to customer specifications. Non-Cancelable Non-Returnable.

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > SWITCHES-DISCONNECTORS

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

SENTRON, Switch disconnector 3LD, breaker, 3-pole, Iu: 32 A, Operating power / at AC- 23 A at 400 V: 11.5 kW, floor mounting with door coupling, without
Model
product brand nameSENTRON
product designation3LD Switch disconnector
design of the productSwitch
display version / for switch position indicator manual operation1 ON - 0 OFF
design of handlewithout
type of the driving mechanism / motor driveNo
General technical data
number of poles3
type of devicefixed mounting
type of switchFloor mounting with door coupling
size of switch disconnector2
mechanical service life (switching cycles) / typical100 000
electrical endurance (switching cycles)
● at AC-23 A / at 690 V6 000
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum9 kA2.s
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum9 kA2.s
operating frequency / maximum50 1/h
Voltage
insulation voltage / rated value690 V
surge voltage resistance / rated value6 kV
Protection class
protection class IPIP65
degree of protection NEMA rating1, 3R, 4X, 12
protection class IP / on the frontIP65
Dissipation
power loss [W]
● for rated value of the current / at AC / in hot operating state / per pole1.8 W
● per conductor / typical2 W
Current
operational current
● at 40 °C / rated value32 A
● at 45 °C / rated value32 A
● at 50 °C / rated value32 A
● at 55 °C / rated value32 A
● at AC / rated value32 A
● at AC-23 A / at 400 V / rated value22 A
● at AC-21 / at 690 V / rated value32 A
● at AC-21 A / at 240 V / rated value32 A
● at AC-21 A / at 440 V / rated value32 A
operational current / of upstream fuse / rated value40 A
let-through current / with closed switch
● at 440 V / for combination switch + gG fuse / maximum4.5 kA
● at 690 V / for combination switch + gG fuse / maximum permissible5 kA
Main circuit
operating power
● at AC-23 A / at 240 V / rated value6 kW
● at AC-23 A / at 400 V / rated value12 kW
● at AC-23 A / at 440 V / rated value11.5 kW
● at AC-23 A / at 690 V / rated value12 kW
● at AC-3 / at 240 V / rated value5.5 kW
● at AC-3 / at 400 V / rated value10 kW
● at AC-3 / at 690 V / rated value9.5 kW
operational current / rated value32 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
operating voltage / of auxiliary contacts / at AC / maximum500 V
continuous current / of the auxiliary contact / rated value10 A
insulation voltage / of the auxiliary switch / rated value500 V
Suitability
suitability for use
● main switchYes
● switch disconnectorYes
● EMERGENCY OFF switchNo
● safety switchYes
● maintenance/repair switchYes
Product details
product extension / optional
● motor driveNo
● voltage triggerNo
Short circuit
conditional short-circuit current / with line-side fuse protection
● at 690 V / by gG fuse / rated value50 kA
according UL
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value32 A
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value600 V
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value20
active power [hp] / at AC / at 600 V / according to UL 508/UL 60947-4-1 / rated value20
short-time withstand current (SCCR) / at 600 V / according to UL 508/UL 60947-4-15 kA
continuous current / of upstream fuse / according to UL / rated value80 A
type of fuse / according to ULRK5
Number
number of connectable NC contacts / for auxiliary contacts / attachable / maximum3
number of connectable NO contacts / for auxiliary contacts / attachable / maximum5
number of connectable CO contacts / for auxiliary contacts / attachable / maximum0
Connections
AWG number / as coded connectable conductor cross section / solid
● maximum8
● minimum14
type of connectable conductor cross-sections / for copper conductor
● solid1x (1,5...16mm²)
● finely stranded / with core end processing1x (1,5...10mm²)
● stranded1x (1,5...16mm²)
type of connectable conductor cross-sections / for auxiliary contacts
● solidlateral auxiliary switch 2x (0,75 ... 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 ... 2,5mm²)
● finely stranded / with core end processinglateral auxiliary switch 2x (0,75 ... 1,5mm²), 1x 2,5mm²; front auxiliary switch 1x 2,5mm²
● strandedlateral auxiliary switch 2x (0,75 ... 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 ... 2,5mm²)
type of electrical connection
● for main current circuitbox terminal
● for auxiliary contactsconnection terminals
Requirements
design of the fuse link
● for short-circuit protection of the main circuit / requiredfuse gL/gG: 40 A
● for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A
Mechanical Design
height68 mm
width46 mm
depth95 mm
fastening methodBuilt-in unit fixed-mounted version
fastening method
● 4-hole front mountingNo
● front mounting with central attachmentNo
● rail mountingYes
net weight142 g
Environmental conditions
ambient temperature / during operation
● minimum-25 °C
● maximum55 °C
ambient temperature / during storage / minimum-25 °C

Downloads and manuals

General Product ApprovalDeclaration of Conformity

CSA

CCC

Confirmation

UL

EAC

EC/EU-Declaration of Conformity

Declaration of ConformityTest Certificatesother

UK Declaration of Conformity

Special Test Certificate

Environmental Confirmations

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/12/2022


Additional data

Product
Article Number (Market Facing Number)3LD2210-0TK00-0AF1
Product DescriptionSENTRON, Switch disconnector 3LD, breaker, 3-pole, Iu: 32 A, Operating power / at AC- 23 A at 400 V: 11.5 kW, floor mounting with door coupling, without
Product familyNot available
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12R / 1CL
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsECCN : N / AL : N
Standard lead time ex-works130 Day/Days
Net Weight (kg)0,138 Kg
Packaging Dimension70,00 x 115,00 x 80,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Minimum order quantity100
Additional Product Information
EAN4011209691087
UPCNot available
Commodity Code85362010
LKZ_FDB/ CatalogIDLV10.1
Product Group5887
Group CodeP360
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 12.12.2006
Product classD: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer)
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
Not available

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.