ANUNCIAR
3KC6434-2TA20-0TA3 SIEMENS SENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu:.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3KC6434-2TA20-0TA3 SIEMENS SENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu:..

3KC6434-2TA20-0TA3

SIEMENS

SENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu: 160 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 125 A, Ie at AC-23 A at 690 V: 80 A, screw and standard mounting rail on 35 mm, motorized operating mechanism, at the right end, long handle, box terminal

ATSE TRANSFER SWITCH, 160A, 4-POLE FRONT ACCONAMIENTO BASE UNIT WITH SELF-POWERED HANDLE FRAME TERMINALS. Cancelations and returns limited. Consult conditions.

More details


Low-voltage industrial components > Switch disconnector

POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > 3KD Switch-disconnectors, 3KC Power Switches

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $3,107.81
Unit price: $3,107.81
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC000216 - Switch disconnector

Value Unit
Degree of protection (NEMA) (EF011959) -
Rated permanent current at AC-23, 400 V (EF011777) -A
Version as main switch (EF006981) true
Version as maintenance-/service switch (EF006986) true
Version as safety switch (EF006985) true
Version as emergency stop installation (EF006959) false
Version as reversing switch (EF009408) -
Number of switches (EF005586) -
Max. rated operation voltage Ue AC (EF007355) 415V
Rated operating voltage (EF001435) ['176.0', '288.0']V
Rated permanent current Iu (EF001389) 160.0A
Rated permanent current at AC-21, 400 V (EF009165) 125A
Rated short-time withstand current lcw (EF007050) 4.0kA
Number of poles (EF001391) 4
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 6
Motor drive optional (EF007386) false
Motor drive integrated (EF006697) true
Voltage release optional (EF007491) false
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for floor mounting (EF007243) FALSE
Suitable for front mounting 4-hole (EF007247) false
Suitable for front mounting centre (EF007248) false
Suitable for distribution board installation (EF007262) true
Suitable for intermediate mounting (EF007264) true
Colour control element (EF007167) Black
Type of control element (EF006976) Long turning handle
Interlockable (EF006281) true
Type of electrical connection of main circuit (EF006819) Frame clamp
Degree of protection (IP), front side (EF003118) IP00
Switching power at 400 V (EF009166) -kW
Conditioned rated short-circuit current Iq (EF001444) -kA
Rated operation power at AC-3, 400 V (EF001364) -kW
Rated operation power at AC-23, 400 V (EF007027) -kW


SENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu: 160 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 125 A, Ie at AC-23 A at 690 V: 80 A, screw and standard mounting rail on 35 mm, motorized operating mechanism, at the right end, long handle, box terminal
Model
product brand nameSENTRON
Product familyATE
Product designation3KC transfer switching equipment
Design of the productautomatic
Design of the operating mechanismLong rotary knob
Design of handleHandle
Type of the driving mechanismmotorized operating mechanism
Type of the driving mechanism / motor driveYes
General technical data
number of poles4
Type of devicefixed mounting
I2t value
● of the fuse / at 415 V / maximum permissible109 000 A²·s
● with closed switch / for combination switch + fuse / at 415 V / maximum109 000 A²·s
Pulse duration / minimum0.06 s
Mechanical service life (switching cycles) / for function sequence O-I-O / typical7 000
Position / of the switch operating mechanismat the right end
overvoltage categoryII
Degree of pollution3
Insulation voltage
● rated value800 V
● with degree of pollution 3 / at DC / rated value800 V
Supply voltage
Operating current / at AC / rated value160 A
Supply voltage / at AC
● minimum176 V
● maximum288 V
Operating voltage
● at AC / at 50/60 Hz / rated value415 V
Protection class
Protection class IPIP00
● Protection class IP / with closed switch / with cover or cable lug coverIP20
● protection class IP / on the frontIP20
Dissipation
Power loss [W]
● with conventional rated thermal current / per pole8.7 W
● with conventional rated thermal current / per device34.8 W
● for rated value of the current / at AC / in hot operating state / per pole8.7 W
Operating current
● at AC-23 B / at 690 V / rated value80 A
● at AC-22 B / at 690 V / rated value125 A
● at AC-21 B / at 690 V / rated value125 A
● at AC-23 A / at 690 V / rated value80 A
● at AC-22 A / at 690 V / rated value100 A
● at AC-21 / at 690 V / rated value125 A
● at AC-21 A / at 415 V / rated value125 A
● at AC-21 B / at 415 V / rated value160 A
● at AC-22 A / at 415 V / rated value125 A
● at AC-22 B / at 415 V / rated value160 A
● at AC-23 A / at 415 V / rated value125 A
● at AC-23 B / at 415 V / rated value160 A
● at AC-31 A / at 415 V / rated value100 A
● at AC-31 B / at 415 V / rated value160 A
● at AC-32 A / at 415 V / rated value100 A
● at AC-32 B / at 415 V / rated value160 A
● at AC-33 B / at 415 V / rated value125 A
● at AC-33 iB / at 415 V / rated value160 A
● at AC / at 230 V / Rated value0.03 A
Continuous current
● rated value160 A
● at 40 °C / rated value160 A
● at 50 °C / rated value125 A
● at 60 °C / rated value125 A
● at 70 °C / rated value100 A
Operating current / of upstream fuse / rated value160 A
Main circuit
Operating frequency / rated value
● minimum45 Hz
● maximum65 Hz
Operating power
● at AC-23 A / at 690 V / at 50/60 Hz / rated value75 kW
Operating current / rated value160 A
Auxiliary circuit
Number of connected NC contacts / for auxiliary contacts0
Number of connected NO contacts / for auxiliary contacts0
Number of connected CO contacts / for auxiliary contacts0
Number of CO contacts / for auxiliary contacts6
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Suitability for use
● Main switchYes
● switch disconnectorYes
● EMERGENCY OFF switchNo
● safety switchYes
● maintenance/repair switchYes
Product feature / interlockYes
Product extension / Auxiliary switchYes
Product extension / optional
● motor driveNo
● Voltage triggerNo
Short circuit
Short-circuit current making capacity (Icm) / for switch disconnector
● at AC 415 V / without fuse link / acc. to IEC 60947-3 / rated value / minimum5.88 kA
Conditional short-circuit current / with line-side fuse protection
● at 415 V / by gG fuse / acc. to IEC 60947-6-1 / rated value40 kA
● at 415 V / by gG fuse / rated value40 kA
number of digital inputs3
Relay design1 relay: 1NO, 250 V AC 2 A AC-1 or 30 V DC 2 A DC-1
Design of the switching inputConnected with control terminal
Input current / at digital input / with signal <0> / maximum0.5 mA
Input delay time0.03 s
Measuring procedureThree-phase, true RMS
Input impedance / between L and L5.5 MΩ
Voltage measuring range / at the measurement inputs
● between L and L / minimum288 V
● between L and L / maximum498 V
Measured variable voltage
● between L and L / Rated value400 V
● between N and L / Rated value230 V
Relative measurement deviation3 %
Number of monitored phases3
Connections
Type of connectable conductor cross-sections / for copper conductor
● solid1x(1070 mm²)
● stranded1x(1070 mm²)
● type of electrical connection / of the inputs and outputsRemovable/insertable
● Type of electrical connection / for main current circuitbox terminal
Mechanical Design
Height245 mm
Width340 mm
Depth73.5 mm
Mounting typeScrew fixing and standard rail mounting 35 mm
● Mounting type / front mounting with 4-hole attachmentNo
● Mounting type / front mounting with central attachmentNo
● mounting type / rail mountingYes
net weight3 542 g
Environmental conditions
Ambient temperature / during operation
● minimum-20 °C
● maximum70 °C
Ambient temperature / during storage
● minimum-40 °C
● maximum70 °C
Certificates
● reference code / acc. to DIN EN 61346-2Q
● Reference code / acc. to DIN EN 81346-2Q
General Product ApprovalDeclaration of Conformity

CCC

Miscellaneous

EC/EU-Declaration of Conformity

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications


Product
Article Number (Market Facing Number)3KC6434-2TA20-0TA3
Product DescriptionSENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu: 160 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 125 A, Ie at AC-23 A at 690 V: 80 A, screw and standard mounting rail on 35 mm, motorized operating mechanism, at the right end, long handle, box terminal
Product familyBasic Devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group12S
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works5 Day/Days
Net Weight (kg)4,243 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension300,00 x 400,00 x 120,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4001869527468
UPCNot available
Commodity Code85365080
LKZ_FDB/ CatalogIDLV10
Product Group5380
Group CodeP360
Country of originTunisia
Compliance with the substance restrictions according to RoHS directiveSince: 31.07.2015
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-14-03
eClass7.127-37-14-03
eClass827-37-14-03
eClass927-37-14-03
eClass9.127-37-14-03
ETIM5EC000216
ETIM6EC000216
ETIM7EC000216
UNSPSC1539-12-22-33

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.