VS-M12FSDBP-M12MSD-936-LI/0,5 1402334 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VS-M12FSDBP-M12MSD-936-LI/0,5 1402334 PHOENIX CONTACT Bus system cable

VS-M12FSDBP-M12MSD-936-LI/0,5

1402334

PHOENIX_CONTACT

50

Product on demand only, returns will not be accepted.

Bus system cable

M12 Built-in Mounting Plug-in Connector, 4 Poles, D-Coded, for Rear Wall Mounting, with PROFINET (RADOX®) Cable on M12 Connector, Length: 0.5 m

M12 flush-type connector, 4-pos., D-coded, for rear mounting, with PROFINET cable (RADOX®) to M12 male connector, length: 0.5 m

More details


Cables > Data and communication cable

Field Device Connectors (FDC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $4,058.66
Unit price: $81.17
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Notes
Order information:Lock nut is included in the scope of delivery

Product properties
Product typeCircular connectors (device side)
Number of positions4
Number of slots1

Electrical properties
Nominal voltage UN48 V AC
Nominal current INPlug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed

Cable/line
Cable length0.50 m
PROFINET RADOX® railway application CAT5 reinforced [936]
Dimensional drawingjtvtrckflp.jpg
Cable weight81 g/m
Number of positions4
Shieldedyes
Cable typePROFINET RADOX® railway application CAT5 reinforced [936]
Conductor structure1x4xAWG22/7, SF/TQ
Signal speed66 c
Conductor structure signal line7x 0.25 mm
AWG signal line22
Conductor cross section4x 0.34 mm²
Wire diameter incl. insulation1.95 mm
External cable diameter7.25 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005
Conductor materialsilver-plated Cu litz wires
Material wire insulationPE-X
Single wire, colorwhite-blue, orange-yellow
Thickness, outer sheath≥ 0.80 mm
Overall twistStar quad
Optical shield covering100 %
Max. conductor resistance≤ 54.4 Ω/km
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Working capacitance≤ 65 pF (Line-line)
≤ 100 pF (Line-shield)
Nominal voltage, cable300 V AC
Test voltage2000 V AC (50 Hz, 5 minutes)
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation44 mm
Smallest bending radius, movable installation73 mm
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Return attenuation (RL)35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT)80 dB (with 1 MHz)
70 dB (at 4 МHz)
65 dB (at 10 MHz)
58 dB (at 31.5 МHz)
59 dB (at 62.5 МHz)
67 dB (at 100 MHz)
Shield attenuation2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
40.00 dB (30 MHz ≤ f ≤ 100 MHz)
Halogen-freein accordance with EN 50267-2-1
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (Cable, flexible installation)

ETIM for 1402334 Cable (EC003249)
Feature Name Feature Value
Conductor surface (EF010804) Other
Diameter conductor (EF001621) 1.95 mm
Nominal cross section conductor (EF000060) 0.34 mm²
Conductor category (EF001632) Class 2 = stranded
Number of cores (EF001792) 4
Core identification (EF000067) Other
Screen over stranding element (EF001623) Foil + braiding
Longitudinal water blocking cable (EF011011) No
Radial water blocking cable (EF011012) No
Suitable for underground installation (EF003689) No
Protective sheath (EF001691) None
Material outer sheath (EF001625) Other
Specification material outer sheath (EF011806) Other
Colour outer sheath (EF001618) Other
Low smoke according to EN IEC 61034-2 (EF003799) No
Oil resistant according to EN IEC 60811-404 (EF009770) No
Outer diameter approx. (EF003921) 7.25 mm
Min. permitted bending radius, moving application/free movement (EF011802) 73 mm
Min. permitted bending radius, stationary application/permanent installation (EF011803) 44 mm
Permitted cable outer temperature during assembling/handling (EF001685) -40 °C
Permitted cable outer temperature after assembling without vibration (EF001686) -50 °C
Category (EF001619) Other

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX CONNECTORS EN.pdf 68 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.