Voltmeter changeover switch, with 0 position, Connection method: Screw connection, Function: L3-L1 ‑ L2-L3 ‑ L1-L2 ‑ 0 ‑ L1-N ‑ L2-N ‑ L3-N, Switching zones: 2, Switching program number: S0004, Rated continuous current: 20 A, Voltage: 690 V

More details


CLIPLINE 1 rail terminals - PHOENIX CONTACT

Industry solutions

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$45.55
6+$40.51
11+$39.42
16+$38.86
22+$38.44
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



General

Number of connections12
Colorsilver/black
Rotary switch functionL3-L1 ‑ L2-L3 ‑ L1-L2 ‑ 0 ‑ L1-N ‑ L2-N ‑ L3-N
Switching program numberS0004
Switching angle45 °

General

Rated continuous current20 A
Maximum load current20 A
Rated surge voltage6 kV
Rated insulation voltage690 V
Additional textValid for networks with grounded neutral point, overvoltage category III, pollution degree 3
Rated operating current according to AC-15 (switching of solenoid drives, contactors, valves, pulling electromagnets)5 A (220 - 240 V)
4 A (380 - 440 V)
Rated operating current according to AC-21A (switching of ohmic loads including small overloads)20 A
Rated operating current according to AC-22A (switching of mixed ohmic and inductive loads, including small overloads)20 A (220 - 500 V)
20 A (660 - 690 V)
Switching power according to AC-3 (squirrel-cage motors: direct starting, switching off motors during operation, star-delta startup (CH16B))3 kW (220 - 240 V; 3-phase, 3-pos.)
5.5 kW (380 - 440 V; 3-phase, 3-pos.)
5.5 kW (500 V; 3-phase, 3-pos.)
5.5 kW (660 - 690 V; 3-phase, 3-pos.)
0.6 kW (110 - 120 V; 1-phase, 2-pos.)
2.2 kW (220 - 240 V; 1-phase, 2-pos.)
3 kW (380 - 440 V; 1-phase, 2-pos.)
Switching power according to AC-4 (squirrel-cage motors: starting, reversing, plugging, inching)0.55 kW (220 - 240 V; 3-phase, 3-pos.)
1.5 kW (380 - 440 V; 3-phase, 3-pos.)
1.5 kW (500 V; 3-phase, 3-pos.)
1.5 kW (660 - 690 V; 3-phase, 3-pos.)
0.3 kW (110 - 120 V; 1-phase, 2-pos.)
0.75 kW (220 - 240 V; 1-phase, 2-pos.)
1.5 kW (380 - 440 V; 1-phase, 2-pos.)
Switching power according to AC-23A (frequent switching of motors or other highly inductive loads)3.7 kW (220 - 240 V; 3-phase, 3-pos.)
7.5 kW (380 - 440 V; 3-phase, 3-pos.)
7.5 kW (500 V; 3-phase, 3-pos.)
7.5 kW (660 - 690 V; 3-phase, 3-pos.)
0.75 kW (110 - 120 V; 1-phase, 2-pos.)
2.5 kW (220 - 240 V; 1-phase, 2-pos.)
3.7 kW (380 - 440 V; 1-phase, 2-pos.)
Breaking capacity150 A (220 - 240 V)
150 A (380 - 440 V)
80 A (660 - 690 V)
Ambient temperature (operation)-35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C)
IP immunity to short-circuiting with maximum backup fuse25 A
Additional textgL/gG characteristics
Rated short-time current resistance140 A
Additional text1 s current

Dimensions

Width48 mm
Length81.5 mm
Height48 mm
Hole diameter7 mm
Height29.00 mm
Installation depth43.00 mm

Ambient conditions

Ambient temperature (operation)-35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C)

Connection data

Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.14
Conductor cross section flexible min.0.75 mm²
Conductor cross section flexible max.2.5 mm²
Min. AWG conductor cross section, flexible18
Max. AWG conductor cross section, flexible14
Conductor cross section / stranded with ferrule without plastic sleeve min.2.5 mm²
Conductor cross section / stranded with ferrule without plastic sleeve max.2.5 mm²
Conductor cross section / stranded with ferrule with plastic sleeve min.1.5 mm²
Conductor cross section / stranded, with ferrule with plastic sleeve max.1.5 mm²
2 conductors with same cross section, solid min.0.5 mm²
2 conductors with same cross section, solid max.2.5 mm²
Two conductors with the same cross section, AWG solid min.20
Two conductors with the same cross section, AWG solid max.14
2 conductors with same cross section, stranded min.0.75 mm²
2 conductors with same cross section, stranded max.2.5 mm²
Two conductors with the same cross section, AWG stranded, min.18
Two conductors with the same cross section, AWG stranded, max.14
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, minimum2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, maximum2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, minimum1.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, maximum1.5 mm²

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-3069701-RS20-US-S0007-0307-014H-001 English 128 Kbytes PHOENIX CONTACT-3069701-RS20-US-S0007-0307-014H-001

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.