VAL-MS-T1/T2 335/12.5/3+1-PT 1266415 PHOENIX CONTACT Universal plug-in surge protection device / lightning c.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS-T1/T2 335/12.5/3+1-PT 1266415 PHOENIX CONTACT Universal plug-in surge protection device / lightning c..

VAL-MS-T1/T2 335/12.5/3+1-PT

1266415

PHOENIX_CONTACT

Universal plug-in surge protection device / lightning current equipped with varistors for three-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE) for lightning protection classes III and IV. Cable connection via push-in connection technology.

Universal varistor-based plug-in lightning/surge protective device for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), for lightning protection levels III and IV. Cables connected via Push-in connection technology.

More details


Earthing, lightning and surge protection > Lightning current arrester for power supply systems

Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
IEC test classificationI / II
T1 / T2
EN typeT1 / T2
IEC power supply systemTT
TN-S
TypeDIN rail module, two-section, divisible
Product typeArrester combination
Product familyVALVETRAB MS
Number of positions4
Surge protection fault messageoptical
Insulation characteristics
Overvoltage categoryIII
Pollution degree2

Electrical properties
Nominal frequency fN50 Hz (60 Hz)

Connection data
Cross section AWG(converted acc. to IEC)
Connection methodPush-in connection
Stripping length10 mm ... 12 mm
Conductor cross section rigid0.5 mm² ... 10 mm²
Conductor cross section AWG20 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve0.5 mm² ... 6 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.5 mm² ... 10 mm²

Dimensions
Dimensional drawingxnxciagtxl.jpg
Width71.2 mm
Height89.8 mm
Depth76.6 mm (incl. DIN rail 7.5 mm)
Horizontal pitch4 Div.

Material specifications
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPA 6.6/PBT
Material groupI
Housing materialPA 6.6
PBT

Mechanical properties
Mechanical data
Open side panelNo

Protective circuit
Mode of protectionL-N
L-PE
N-PE
Direction of action3L-N & N-PE
Nominal voltage UN240/415 V AC (TN-S)
240/415 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC(L-N)335 V AC
Maximum continuous operating voltage UC(L-PE)335 V AC
Maximum continuous operating voltage UC(N-PE)264 V AC
Rated load current IL32 A (at 6 mm²)
40 A (at 10 mm²)
Residual current IPE≤ 5 µA
Standby power consumption PC≤ 810 mVA
Nominal discharge current In(8/20) µs (L-N)12.5 kA
Nominal discharge current In(8/20) µs (L-PE)12.5 kA
Nominal discharge current In(8/20) µs (N-PE)50 kA
Maximum discharge current Imax(8/20) µs50 kA
Impulse discharge current (10/350) µs (L-N), charge6.25 As
Impulse discharge current (10/350) µs (L-N), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA
Impulse discharge current (10/350) µs (L-PE), charge6.25 As
Impulse discharge current (10/350) µs (L-PE), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp12.5 kA
Impulse discharge current (10/350) µs (N-PE), charge25 As
Impulse discharge current (10/350) µs (N-PE), specific energy625 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp50 kA
Total discharge current Itotal(8/20) µs50 kA
Total discharge current Itotal(10/350) µs50 kA
Follow current interrupt rating Ifi(N-PE)100 A
Short-circuit current rating ISCCR25 kA
Voltage protection level Up(L-N)≤ 1.2 kV
≤ 1.6 kV (30 kA - 8/20 µs)
Voltage protection level Up(L-PE)≤ 2 kV
Voltage protection level Up(N-PE)≤ 1.7 kV
Residual voltage Ures(L-N)≤ 1.2 kV (at In)
≤ 1.1 kV (at 10 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 3 kA)
Residual voltage Ures(L-PE)≤ 2 kV (at In)
≤ 1.5 kV (at 10 kA)
≤ 1.2 kV (at 5 kA)
≤ 1.1 kV (at 3 kA)
Residual voltage Ures(N-PE)≤ 0.6 kV (at In)
≤ 0.5 kV (at 10 kA)
≤ 0.5 kV (at 5 kA)
≤ 0.4 kV (at 3 kA)
TOV behavior at UT(L-N)415 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
TOV behavior at UT(L-PE)415 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
1657 V AC (200 ms / withstand mode)
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Response time tA(L-N)≤ 25 ns
Response time tA(L-PE)≤ 100 ns
Response time tA(N-PE)≤ 100 ns
Max. backup fuse with V-type through wiring32 A (gG - 6 mm²)
35 A (gG - 10 mm²)
40 A (MCB C - 10 mm²)
Max. backup fuse with branch wiring160 A (gG)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

Standards and regulations
Standards/specificationsIEC 61643-11
Note2011
Standards/specificationsEN 61643-11
Note2012

Mounting
Mounting typeDIN rail: 35 mm

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN .pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.