UHV 95-KH/AS 2130127 PHOENIX CONTACT High Current Connectors View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

UHV 95-KH/AS 2130127 PHOENIX CONTACT High Current Connectors

UHV 95-KH/AS

2130127

PHOENIX_CONTACT

High Current Connectors

More details


Enclosures connectivity

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2130127
Packing unit10 pc
Catalog pagePage 555 (C-1-2017)
GTIN4017918052904
Weight per Piece (excluding packing)296.230 g
Custom tariff number85369010
Country of originIN (India)

General

Number of levels1
Number of connections2
Nominal cross section95 mm²
Colorgray
Insulating materialPA-F
Flammability rating according to UL 94V0
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupII
Maximum power dissipation for nominal condition7.54 W
Connection in acc. with standardIEC 60947-7-1
Nominal current IN232 A
Maximum load current232 A (with 95 mm2conductor cross section)
Nominal voltage UN1000 V
Connection in acc. with standardIEC 60947-7-1
Nominal current IN(upper level)232 A
Maximum load current (upper level)232 A (with 95 mm2conductor cross section)
Nominal voltage UN1000 V
Open side panelNo
Result of surge voltage testTest passed
Surge voltage test setpoint9.8 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint2.2 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed
Result of bending testTest passed
Bending test conductor cross section/weight25 mm² / 4.5 kg
35 mm² / 6.8 kg
95 mm²/14 kg
Tensile test resultTest passed
Conductor cross section tensile test25 mm²
Tractive force setpoint135 N
Conductor cross section tensile test35 mm²
Tractive force setpoint190 N
Conductor cross section tensile test95 mm²
Tractive force setpoint351 N
Result of tight fit on supportTest passed
Tight fit on carrierNS 32/NS 35
Setpoint15 N
Result of voltage-drop testTest passed
Requirements, voltage dropU1≤ 3.2 mV
Result of temperature-rise testTest passed
Short circuit stability resultTest passed
Conductor cross section short circuit testing95 mm²
Short-time current11.4 kA
Result of thermal testTest passed
Proof of thermal characteristics (needle flame) effective duration30 s
Relative insulation material temperature index (Elec., UL 746 B)120 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C

Dimensions

Length114 mm
Width40 mm
Height NS 35/1586 mm

Connection data

Connection methodBolt connection
Conductor cross section solid min.35 mm²
Conductor cross section solid max.95 mm²
Conductor cross section flexible min.35 mm²
Conductor cross section flexible max.95 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min.35 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.95 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.95 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.16 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.35 mm²
Cable lug connection according to standardDIN 46234
Min. cross section for cable lug connection10 mm²
Max. cross section for cable lug connection95 mm²
Hole diameter, min.13 mm
Bolt diameter12 mm
Screw threadM12
Tightening torque, min25 Nm
Tightening torque max30 Nm
Cable lug connection according to standardDIN 46235
Min. cross section for cable lug connection25 mm²
Max. cross section for cable lug connection95 mm²
Hole diameter, min.13 mm
Bolt diameter12 mm
Screw threadM12
Tightening torque, min25 Nm
Tightening torque max30 Nm
Stripping length29 mm
Screw threadM12
Tightening torque, min25 Nm
Tightening torque max30 Nm
Power rail30 mm x 5 mm
Connection methodScrew connection
Conductor cross section solid min.25 mm²
Conductor cross section solid max.95 mm²
Conductor cross section flexible min.35 mm²
Conductor cross section flexible max.95 mm²
Conductor cross section AWG min.3
Conductor cross section AWG max.3/0
Conductor cross section flexible, with ferrule without plastic sleeve min.35 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.95 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.95 mm²
2 conductors with same cross section, solid min.25 mm²
2 conductors with same cross section, solid max.35 mm²
2 conductors with same cross section, stranded min.25 mm²
2 conductors with same cross section, stranded max.35 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.16 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.35 mm²
Stripping length29 mm
Screw threadM8
Tightening torque, min15 Nm
Tightening torque max20 Nm

Standards and Regulations

Connection in acc. with standardCSA
IEC 60947-7-1
IEC 60947-7-1
Flammability rating according to UL 94V0

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.