Product successfully added to your shopping cart
CB TM1 8A F1 P
2800864
PHOENIX_CONTACT
1
Thermomagnetic device circuit breaker
Interrupt. protec. thermomagnetic, 1 pole, caract curve. activ. F1 (fast), 1 inverted contact, connector for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic F1 (fast-blow), 1 changeover contact, plug for base element.
Circuit breakers and fuses > Device circuit breaker
Over Current Protection
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| General | When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly. |
| Product type | Thermomagnetic device circuit breakers |
| Product family | CB TM |
| Type | Male |
| Number of positions | 1 |
| No. of channels | 1 |
| Data management status | |
| Article revision | 06 |
| Insulation characteristics | |
| Degree of pollution | 2 |
| Fuse type | Automatic device |
| General | |
| Rated voltage | 50 V DC (IEC 60934) |
| 50 V DC (UL 1077) | |
| 50 V DC (UL 508 - with plug-in base) | |
| Rated insulation voltage Ui | 277 V AC (UL 1077) |
| 250 V AC (IEC 60934) | |
| Rated current IN | 8 A (IEC 60934) |
| inductive load according to UL 1077 | |
| 8 A DC (low-induction load according to UL 1077) | |
| 8 A DC (inductive load according to UL 508 - with plug-in base) | |
| 8 A DC (low-induction load according to UL 508 - with plug-in base) | |
| Rated surge voltage | 2.5 kV (Increased insulation in actuation area) |
| Insulation resistance Riso | > 100 MΩ (500 V DC) |
| Auxiliary circuit | 277 V AC / 0.5 A (Low-induction) |
| 277 V AC / 1 A (Low-induction, maximum of 2000 cycles) | |
| 50 V DC / 1 A (Low-induction) | |
| Type of actuation | S type |
| Tripping method | TM (thermomagnetic) |
| Tripping level | Trip-free mechanism (positive) |
| Device resistance | 18 mΩ |
| Required backup fuse | 32 A (I > Icn) |
| Rated short-circuit switching capacity Icn | 600 A (50 V DC) |
| Short-circuit switching capacity | 1000 A AC (277 V AC) |
| 1000 A DC (50 V DC) | |
| Dielectric strength | 3000 V AC (Actuation area) |
| 1500 V AC (Main to auxiliary circuit) | |
| 1500 V AC (Open main circuit) | |
| 1000 V AC (Open auxiliary circuit) | |
| Switching cycles, max. | 6000 (at 1 x In) |
| Fuse | F1 (fast blow) |
| Power dissipation | 1.28 W (in nominal operation per channel) |
| Voltage drop | 0.14 V (at 1 x In) |
| Auxiliary contact | |
| Minimum operating voltage UminDC | 10 V |
| Maximum operating voltage UmaxDC | 240 V |
| Maximum operating voltage Umax.AC | 240 V |
| Minimum operating current Imin | 10 mA |
| Max. operating current Imax | 1 A |
| Connection method | pluggable |
| Connection method | pluggable |
| Dimensional drawing | ![]() |
| Width | 12.3 mm |
| Height | 45 mm |
| Depth | 52 mm |
| Complete module width | 12.3 mm |
| Complete module height | 90 mm |
| Complete module depth | 77.3 mm |
| Color | gray (RAL 7042) |
| black (RAL 9005) | |
| Flammability rating according to UL 94 | V-0 |
| Insulating material group | II |
| Mechanical data | |
| Open side panel | No |
| Ambient conditions | |
| Degree of protection | IP30 (Actuation area) |
| Ambient temperature (operation) | -30 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Humidity test | 240 h, 95 % RH, 40 °C |
| Shock (operation) | 15g (IEC 60068-2-27, Test Ea) |
| Vibration (operation) | 5g (IEC 60068-2-6, Test Fc) |
| UL approval | |
| Identification | UL Listed UL 508 |
| UL/C-UL Recognized UL 1077 | |
| CSA | |
| Identification | CSA CAN/CSA-C22.2 No. 235-04 |
| Shipbuilding approval | |
| Identification | DNV GL |
| Standards/specifications | EN 60934 |
| Mounting type | on base element |
| Feature Name | Feature Value |
|---|---|
| Inflammability class of insulation material according to UL94 (EF002521) | Other |
| Number of poles (EF001391) | 1 |
| Construction type (EF000767) | Plug |
| Width (EF000008) | 12.3 mm |
| Height (EF000040) | 45 mm |
| Depth (EF000049) | 52 mm |
| Mounting method (EF000003) | Other |
| Operating voltage (EF000111) | 50 V |
| Nominal current (EF000001) | 8 A |
| Active current limitation x IN (EF011922) | 0 |
| Fuse type (EF011923) | Other |
| With remote signalling contact (EF000422) | No |
| Ambient temperature during operating (EF007515) | -30 °C |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes |
|
| PHOENIX CONTACT-2800864-CB TM1 8A F1 P | 577 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.