STEP3-PS/1AC/5DC/3/PT/USB-C 1335698 PHOENIX CONTACT Primary Switching Power Supplies, STEPPOWER, Push-in Con.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

STEP3-PS/1AC/5DC/3/PT/USB-C 1335698 PHOENIX CONTACT Primary Switching Power Supplies, STEPPOWER, Push-in Con..

STEP3-PS/1AC/5DC/3/PT/USB-C

1335698

PHOENIX_CONTACT

Primary Switching Power Supplies, STEPPOWER, Push-in Connection, Rail Mount, Input: 1-Phase, Output: 5 VDC / 3 A

Primary-switched power supply unit, STEP POWER, Push-in connection, DIN rail or direct mounting, Integrated cable groove with strain relief, input: 1-phase, output: 5 V DC / 3 A, USB-C up to 15 W

More details


Power Supplies (PS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $63.42
Unit price: $63.42

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Viewed products


Related products

More info



Technical data

Input data
AC operation
Supply system configurationStar network (TN, TT, IT (PE))
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Typical national grid voltage120 V AC
230 V AC
Voltage type of supply voltageAC
Inrush currenttyp. 30 A (25 °C)
Inrush current integral (I2t)typ. 0.14 A2s
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 18 ms (120 V AC)
typ. 80 ms (230 V AC)
Current consumption0.3 A (100 V AC)
0.14 A (240 V AC)
Switch-on timetyp. 2 s
Device mains fuse1.25 A internal (device protection), slow-blow
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE< 0.25 mA
DC operation
Input voltage range110 V DC ... 250 V DC -20 % ... +10 %
Voltage type of supply voltageDC
Current consumption0.17 A (110 V DC)
0.07 A (250 V DC)

Output data
Efficiency> 81.5 % (120 V AC)
> 82 % (230 V AC)
Nominal output voltage5 V DC
Nominal output current (IN)3 A
Short-circuit-proofyes
No-load proofyes
Derating> 50 °C ... 70 °C (2 % / K)
Crest factortyp. 3.3
typ. 4.2
Output power (PN)15 W
Connection in parallelyes, for increasing power and redundancy with diode
Connection in seriesyes, for increased output voltage
Feedback voltage resistance≤ 10 V DC
Protection against overvoltage at the output (OVP)< 10 V DC
Residual rippletyp. 80 mVPP
Control deviation< 1.5 % (Static load change 10 % ... 90 %)
< 5 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.1 % (change in input voltage ±10 %)
Rise timetyp. 100 ms (UOut= 10 % ... 90 %)
Minimum no-load power dissipation< 0.1 W (120 V AC)
Maximum no-load power dissipation< 0.1 W (230 V AC)
Minimum nominal load power dissipation< 3.4 W (120 V AC)
Power loss nominal load max.< 3.2 W (230 V AC)

Connection data
Input
Position1.x
Connection technology
Position marking1.1, 1.2 (L), 1.3, 1.4 (N)
Conductor connection
Connection methodPush-in connection
rigid0.2 mm² ... 2.5 mm²
1 mm² (recommended)
flexible0.2 mm² ... 2.5 mm²
1 mm² (recommended)
flexible with ferrule without plastic sleeve0.5 mm² ... 1.5 mm²
1 mm² (recommended)
flexible with ferrule with plastic sleeve0.2 mm² ... 1 mm²
1 mm² (recommended)
rigid (AWG)24 ... 14 (Cu)
17 (recommended)
Stripping length10 mm (rigid/flexible)
13 mm (Ferrule with plastic sleeve)
Output
Position2.x
Connection technology
Position marking2.1 (USB-C)

Signaling
LED signaling
Types of signalingLED
Signal threshold> 0.9 x UN(UN= 5 V DC) (LED lights up green)
< 0.9 x UN(UN= 5 V DC) (LED off)

Electrical properties
Number of phases1.00
Insulation voltage input/output4 kV AC (type test)
3.75 kV AC (routine test)

Product properties
Product typePower supply
Product familySTEP POWER
MTBF (IEC 61709, SN 29500)> 2370000 h (25 °C)
> 1124000 h (40 °C)
> 643000 h (50 °C)
Environmental protection directiveRoHS Directive 2011/65/EU
WEEE
Reach
Insulation characteristics
Protection classII (in closed control cabinet)
Degree of pollution2

Dimensions
Item dimensions
Width18 mm
Height90 mm
Depth61 mm
55 mm (Device depth (DIN rail mounting))
Dimensional drawingifwzvoaibk.jpg
Horizontal pitch1 Div. (DIN 43880)
Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm

Mounting
Mounting typeDIN rail or direct mounting
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingNo

Material specifications
Flammability rating according to UL 94V0 (Housing, terminal blocks, base latches)
Housing materialPlastic
Foot latch materialPolyamid
Housing materialPolycarbonate

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-10 °C ... 70 °C (Derating: > 50 °C; 2 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-25 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock (operation)18 ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.

Standards and regulations
Overvoltage category
EN 61010-1II (≤ 4000 m)
Overvoltage category
EN 62477-1III (≤ 2000 m)
Electrical safety
Standard designationElectrical safety
Standards/specificationsIEC 61010-1 (SELV)
Protective extra-low voltage
Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Safe isolation
Standard designationSafe isolation
Standards/specificationsIEC 61558-2-16
Low-voltage power supplies, DC output
Standard designationLow-voltage power supplies, DC output
Standards/specificationsEN 61204-3
Safety requirements for electrical equipment for measurement, control, and laboratory use
Standard designationSafety requirements for electrical equipment for measurement, control, and laboratory use
Standards/specificationsIEC 61010-1
Household and similar electrical appliances - Safety
Standard designationSafety of electrical devices for household use and similar purposes
Standards/specificationsDIN EN 60335-1

Approvals
UL
IdentificationUL 1310 Class 2 Power Units
UL
IdentificationUL/C-UL Listed UL 61010-1
UL
IdentificationUL/C-UL Listed UL 61010-2-201
UL
IdentificationUL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

EMC data
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
Noise immunityImmunity in accordance with EN 61000-6-2 (industrial)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
EN 61000-6-3 (Class B)
Noise emissionEN 55016
EN 61000-6-3 (Class B)
Harmonic currents
Standards/regulationsEN 61000-3-2
EN 61000-3-2 (Class A)
Flicker
Standards/regulationsEN 61000-3-3
Frequency range0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Inputasymmetrical 2 kV (Test Level 3)
Outputasymmetrical 2 kV (Test Level 3)
CommentsCriterion A
Surge voltage load (surge)
Standards/regulationsEN 61000-4-5
Inputsymmetrical 2 kV (Test Level 4)
asymmetrical 4 kV (Test Level 4)
Outputsymmetrical 1 kV (Test Level 3)
asymmetrical 2 kV (Test Level 3)
CommentsCriterion A
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
Input/Outputasymmetrical
Frequency range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)
Voltage dips
Standards/regulationsEN 61000-4-11
Voltage230 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 periods
Additional textClass 3
CommentsCriterion A
Voltage dip40 %
Number of periods10 periods
Additional textClass 3
CommentsCriterion A
Voltage dip0 %
Number of periods1 period
Additional textClass 3
CommentsCriterion A
Criteria
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN.pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.