By meters, Sensor/actuator cable, shielded, halogen-free PE-X, black, 5-conductor, single conductor color: white 1, white 2, white 3, white 4, white 5, cable length: 100 m, For railway applications
Cable for sensors/actuators
Cables > Data and communication cable
Industrial Field Connectivity (IFC)
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product Type | Data cable by the meter |
| Number of poles | 5 |
| application | Railway applications |
| Shielded | Yes |
| Cable length | 100 m |
| RADOX®black, shielded [28R] | |
| Dimension Scheme | ![]() |
| Shielded | Yes |
| Cable Weight | 70 kg/km |
| Cable type | RADOX®black, shielded |
| Cable Type (abbreviation) | 28R |
| Cable Outer Diameter | 6.2 mm ±0.3 mm |
| Outer Wrap, Material | PE-X |
| Outer Wrap, Color | black |
| Conductive Material | Tinned Cu Conductor |
| Conductor Construction Signal Cable | 19x 0.18 mm |
| AWG Signal Line | 20 |
| Line Section | 5x 0.5 mm² |
| Material: Conductor Insulation | PE-X |
| Conductor diameter incl. insulation | 1.43 mm |
| Single Driver, Color | White 1, White 2, White 3, White 4, White 5 |
| Total cabling | 5 longitudinally stranded conductors |
| Screening | Tinned Copper Wire Mesh |
| Nominal Voltage Cable | 600 V AC (Conductive-Ground, U)0) |
| 1000 V AC (Conduct-to-Earth, U) | |
| ≤ 720 V AC (conductive-ground) | |
| ≤ 1200 V AC (Ground-Conductor, U)m) | |
| ≤ 900 V DC (Conductive-Ground, V0) | |
| ≤ 1500 V DC (conductor-conductor) | |
| Test Voltage Cable | 3500 V AC (50 Hz, 5 min.) |
| 8400 V DC (50 Hz, 5 min.) | |
| Line Resistance | ≤ 40.1 Ω/km |
| Minimum bending radius, fixed | 3 x D |
| Minimum bending radius, flexibly positioned | 4 x D |
| Fire protection in vehicles on rails | BS 6853 (Category Ia, Ib, II) |
| GM/RT 2130 (Category Ia, Ib, II) | |
| EN 45545 (Hazard Level HL1 - HL3) | |
| DIN 5510 (Fire Protection Level 1, 2, 3, 4) | |
| NF F16-101 (Category A1, A2, B) | |
| NF F16-101 (Class C / F0) | |
| NFPA 130 | |
| UNI IEC 11170 (Hazard Level LR1 - LR4) | |
| Absence of halogens | according to EN 50267-2-1 |
| Oil Resistance | according to IRM 902, 72 h at 100 °C |
| Flue gas density | BS 6853 D.8.7 |
| EN 61034-2 | |
| UL 1685, 12 (FT4) | |
| Fire Gas Toxicity | BS 6853 B.1 |
| EN 50305, 9.2 | |
| Corrosion of fire gases | EN 50267-2-2 |
| Flame Resistance | EN 60332-1-2 |
| EN 50266 | |
| EN 60332-3-25 | |
| NF C32-070, 2.1 | |
| NF C32-070, 2.2 | |
| UL 1685, 12 (FT4) | |
| according to ISO 6722-1 5.22 (UN ECE-R 118.01) | |
| Other resistances | Fuel resistant according to IRM 903, 168 h at 70 °C |
| Ambient Temperature (Service) | -25 °C ... 90 °C (Cable, movable arrangement) |
| -50 °C ... 120°C (cable, fixed arrangement) | |
| Feature Name | Feature Value |
|---|---|
| Conductor surface (EF010804) | Other |
| Diameter conductor (EF001621) | 1.43 mm |
| Nominal cross section conductor (EF000060) | 0.5 mm² |
| Conductor category (EF001632) | Class 6 = very flexible |
| Number of cores (EF001792) | 5 |
| Core identification (EF000067) | Other |
| Screen over stranding element (EF001623) | Braiding |
| Longitudinal water blocking cable (EF011011) | No |
| Radial water blocking cable (EF011012) | No |
| Suitable for underground installation (EF003689) | No |
| Protective sheath (EF001691) | None |
| Material outer sheath (EF001625) | Other |
| Specification material outer sheath (EF011806) | Other |
| Colour outer sheath (EF001618) | Black |
| Low smoke according to EN IEC 61034-2 (EF003799) | No |
| Oil resistant according to EN IEC 60811-404 (EF009770) | No |
| Outer diameter approx. (EF003921) | 6.2 mm |
| Min. permitted bending radius, moving application/free movement (EF011802) | 25 mm |
| Min. permitted bending radius, stationary application/permanent installation (EF011803) | 19 mm |
| Permitted cable outer temperature during assembling/handling (EF001685) | -25 °C |
| Permitted cable outer temperature after assembling without vibration (EF001686) | -50 °C |
| Category (EF001619) | Other |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX CONNECTORS EN.pdf | 57 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.