SAC-4P-M12MSD/ 4,0-936/M12MSD 1401034 PHOENIX CONTACT Bus system cable

SAC-4P-M12MSD/ 4,0-936/M12MSD

1401034

PHOENIX_CONTACT

50

Bus system cable

Bus system cable, PROFINET, 4-pole, halogen-free PE-X, black RAL 9005, shielded, M12 straight male connector, coding: D-coded, a M12 straight male connector, coding: D-coded, cable length: 4 m

More details


Sensors > Sensor-actuator patch cord

Industrial Field Connectivity (IFC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey1401034
Packing unit1
GTIN4046356517461
Custom tariff number85444290

Mechanical characteristics

Number of positions4
Shieldedyes
Insertion/withdrawal cycles≥ 100
Cable diameter7.25 mm
Length of cable4 m
Degree of protectionIP65/IP67/IP69K
No. of cable outlets1

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-40 °C ... 90 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)
Degree of protectionIP65
IP67
IP68

Material data

Flammability rating according to UL 94V0
Contact carrier materialPA 6.6
Contact materialCuSn
Contact surface materialNi/Au
Cable gland materialZinc die-cast, nickel-plated
Sealing materialNBR
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005

Standards and Regulations

Flammability rating according to UL 94V0

Line characteristics

Cable typeEthernet
Cable structure1x4xAWG22/7; SF/TQ
Conductor cross section4x 0.34 mm²
AWG signal line22
Conductor structure signal line7x 0.25 mm
Core diameter including insulation1.95 mm
External cable diameter7.25 mm ±0,3 mm
Wire colorswhite-blue, orange-yellow
External sheath, colorblack RAL 9005
Transmission mediumCopper
Conductor resistance≤ 54.4 Ω/km
Working capacitance≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Wave attenuation2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
Return Loss35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Signal speed66 c
Shield attenuation40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable300 V AC
Test voltage, cable2000 V AC (50 Hz, 5 minutes)
Overall twistStar quad
ShieldingPlastic-coated aluminum foil, tinned copper braided shield
Optical shield covering100 %
Outer sheath, materialPE-X
Material conductor insulationPE-X
Conductor materialsilver-plated Cu litz wires
Cable weight81 g/m
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)

Classifications


Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX CONNECTORS EN.pdf 57 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.