Product successfully added to your shopping cart
IBS RBC METER/E-T
2723149
PHOENIX_CONTACT
1 m.
Product on demand only, returns will not be accepted.
Remote bus cable
By meters, Remote bus cable, INTERBUS, shielded, PVC, black RAL 9005, 6-conductors (3 x 2 x 0.22 mm²), color single conductors: green-yellow, white-brown, gray-pink, for underground laying
By the meter, Remote bus cable, INTERBUS, shielded, PVC, black RAL 9005, 6-wire (3 x 2 x 0.22 mm2), color single wire: green-yellow, white-brown, gray-pink, for underground runs
Cables > Data and communication cable
Industrial Field Connectivity (IFC)
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product type | Remote bus cable |
| Number of positions | 6 |
| Transmission medium | Copper |
| Number of positions | 6 |
| Shielded | yes |
| Conductor structure | 3 x 2 x 0.22 mm² |
| Signal speed | 0.66 c |
| Conductor structure signal line | 7x 0.20 mm |
| Conductor cross section | 3x 2x 0.22 mm² |
| External cable diameter | 9.00 mm |
| Outer sheath, material | PVC |
| External sheath, color | black RAL 9005 |
| Conductor material | Bare Cu litz wires |
| Material wire insulation | PE |
| Single wire, color | green-yellow, white-brown, gray-pink |
| Twisted pairs | 2 cores to the pair |
| Overall twist | 3 pairs to the core |
| Insulation resistance | ≥ 5 GΩ*km |
| Coupling resistance | < 250.00 mΩ/m (at 30 MHz) |
| Loop resistance | ≤ 186.00 Ω/km |
| Wave impedance | 120 Ω ±20 % (at 64 kHz) |
| 100 Ω ±15 % (with 1 MHz) | |
| Cable capacity | ≤ 60 nF/km (At 800 Hz) |
| Nominal voltage, cable | 250 V (Peak value, not for high-power applications) |
| Test voltage Core/Core | 1500 Vrms |
| Test voltage Core/Shield | 1000.00 Vrms |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 15 x D |
| Smallest bending radius, fixed installation | 68 mm |
| Smallest bending radius, movable installation | 135 mm |
| Near end crosstalk attenuation (NEXT) | ≥ 61 dB (at 772 kHz) |
| ≥ 59 dB (with 1 MHz) | |
| ≥ 55 dB (at 2 МHz) | |
| ≥ 50 dB (at 4 МHz) | |
| ≥ 46 dB (at 8 МHz) | |
| ≥ 44 dB (at 10 MHz) | |
| ≥ 41 dB (at 16 MHz) | |
| ≥ 40 dB (at 20 МHz) | |
| Shield attenuation | ≤ 15 dB/km (at 256 kHz) |
| ≤ 24 dB/km (at 772 kHz) | |
| ≤ 27 dB/km (with 1 MHz) | |
| ≤ 52 dB/km (at 4 МHz) | |
| ≤ 84 dB/km (at 10 MHz) | |
| ≤ 112 dB/km (at 16 MHz) | |
| ≤ 119 dB/km (at 20 МHz) | |
| Ambient temperature (operation) | -30 °C ... 70 °C (cable, fixed installation) |
| -5 °C ... 70 °C (Cable, flexible installation) |
| Feature Name | Feature Value |
|---|---|
| Conductor surface (EF010804) | Other |
| Nominal cross section conductor (EF000060) | 0.22 mm² |
| Conductor category (EF001632) | Class 2 = stranded |
| Number of cores (EF001792) | 6 |
| Material core insulation (EF000061) | Other |
| Specification core insulation (EF011805) | Polyethylene (PE) |
| Core identification (EF000067) | Other |
| Screen over stranding element (EF001623) | Braiding |
| Stranding (EF003802) | Other |
| Longitudinal water blocking cable (EF011011) | No |
| Radial water blocking cable (EF011012) | No |
| Suitable for underground installation (EF003689) | No |
| Protective sheath (EF001691) | None |
| Material outer sheath (EF001625) | Polyvinyl chloride (PVC) |
| Specification material outer sheath (EF011806) | Other |
| Colour outer sheath (EF001618) | Other |
| Low smoke according to EN IEC 61034-2 (EF003799) | No |
| Oil resistant according to EN IEC 60811-404 (EF009770) | No |
| Outer diameter approx. (EF003921) | 9 mm |
| Min. permitted bending radius, moving application/free movement (EF011802) | 135 mm |
| Min. permitted bending radius, stationary application/permanent installation (EF011803) | 68 mm |
| Permitted cable outer temperature during assembling/handling (EF001685) | -5 °C |
| Permitted cable outer temperature after assembling without vibration (EF001686) | -30 °C |
| Category (EF001619) | Other |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX CONNECTORS EN.pdf | 57 Mbytes |
|
| PHOENIX CONTACT-2723149-IBS RBC METER/E-T | 99 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.