ANUNCIAR
PLC-RSC-24DC/21/EX 2909524 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-RSC-24DC/21/EX 2909524 PHOENIX CONTACT Relay Module

PLC-RSC-24DC/21/EX

2909524

PHOENIX_CONTACT

Relay Module

PLC-INTERFACE, consisting of a base terminal block for mounting on a 6.2 mm rail with screw connection and plug-in miniature relay with 6 A power contact, 1 switched contact, input voltage of 24 V DC. Approved according to ATEX/IECEx (zone 2) and Ex zone class I, div. 2.

More details


Relays > Switching relay

Industrial Relays

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $22.35
Unit price: $22.35
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey2909524
Packing unit10 pc
Minimum order quantity10 pc
Catalog pagePage 458 (C-5-2017)
GTIN4055626363615
Weight per Piece (excluding packing)36.800 g
Custom tariff number85364190
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (UL)
-40 °C ... 60 °C (ATEX / IECEx)
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V DC
Typical input current at UN9 mA
Typical response time5 ms
Typical release time8 ms
Protective circuitReverse polarity protection Polarity protection diode
Free-wheeling diode Damping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.22 W

Contact side

Contact type1 PDT
Type of switch contactSingle contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage5 V (at 100 mA)
Min. switching current10 mA (at 12 V)
Maximum inrush current10 A (4 s)
Limiting continuous current6 A
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)

General

Test voltage relay winding/relay contact4 kV AC (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionRT III (Relay)
IP20 (Relay base)
Mechanical service life2x 107cycles
ATEX II 3G Ex ec nC IIC T4 Gc
EU-type examination certificateIBExU16ATEXB015 X
IECExEx ec nC IIC T4 Gc
IECEx certificateIECEx IBE 16.0029X
UL, USAClass I, Zone 2, AEx nA nC IIC T6
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, Zone 2, Ex nA nC IIC Gc T6 X
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)36.8 g

Connection data input side

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² ()
2x 0.5 mm² ... 1.5 mm² ()
Conductor cross section AWG26 ... 14

Connection data output side

Connection nameContact side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² ()
2x 0.5 mm² ... 1.5 mm² ()
Conductor cross section AWG26 ... 14

Standards and Regulations

DesignationStandards/regulations
Standards/regulationsIEC 60664
EN 50178
EN 60079-0, -7, -15
Degree of pollution3
Overvoltage categoryIII
Flammability rating according to UL 94V0
ConformanceCE-compliant
ATEX II 3G Ex ec nC IIC T4 Gc
IECExEx ec nC IIC T4 Gc
UL, USAClass I, Zone 2, AEx nA nC IIC T6
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, Zone 2, Ex nA nC IIC Gc T6 X

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2909524 Relays (EC001437)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
Complete with socket (EF003359) Yes
With detachable clamps (EF003340) No
With LED indication (EF005950) Yes
Rated control supply voltage DC (EF003980) 18.5 V
Voltage type for actuating (EF008242) DC
Drive, polarization (EF003355) Polarized
Drive, switching attitude (EF003356) Mono stable
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 1
Type of switch contact (EF003358) Single contact
With forced-guided contacts (EF003357) No
Material of contact insert (EF008521) Other
Material of contact surface (EF004020) Untreated
Nominal current (EF000001) 0.009 A
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 6.2 mm
Height (EF000040) 80 mm
Depth (EF000049) 94 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.