Bus system flush-type socket, Ethernet, 8-pos., M12, shielded, rear/screw mounting with M16 thread, with 1 m bus cable, 4 x 2 x 0.26 mm2

More details


Field Device Connectors (FDC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Mounting
Mounting typeRear mounting, M16 x 1.5 thread with flat nut

Product properties
Product typeCircular connectors (device side)
Number of positions8
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialNBR
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionBrass, nickel-plated
Outer sheath, materialPUR
Conductor materialBare Cu litz wires

Electrical properties
Contact resistance≤ 3 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN30 V
Nominal current IN2 A
Transmission characteristics (category)CAT5 (IEC 11801:2002)
Wave impedance100 Ω
Max. conductor resistance150 mΩ/m

Mechanical properties
Mechanical data
Insertion/withdrawal cycles> 100

Connector
Connection 1
Head designSocket
Head cable outletstraight
Head thread typeM12
CodingA
Connection 2
Head designfree cable end

Cable/line
Cable length0.29 m
Ethernet flexible CAT5, 4-pair [94B]
Dimensional drawingschbwmdziw.jpg
Shieldedyes
UL AWM Style20963 (80°C/30 V)
Cable weight47 kg/km
Cable typeEthernet flexible CAT5, 4-pair
Short symbol02YS(ST)C11Y
Cable type (abbreviation)94B
Signal type/categoryEthernet CAT5 (IEC 11801), 1 Gbps
Cable structure4x2xAWG26/7, SF/UTP
External cable diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Thickness, outer sheath1.05 mm
Conductor materialBare Cu litz wires
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section4x 2x 0.14 mm²
Material wire insulationFoamed PE
Wire diameter incl. insulation0.96 mm
Single wire, colorwhite/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Twisted pairs2 cores to the pair
Overall twist4 pairs for core
ShieldingAluminum-coated foil, tinned copper braided shield
Optical shield covering70 %
Nominal voltage, cable≤ 100 V
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Cable insulation resistance≥ 5 GΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Loop resistance≤ 290.00 Ω/km
Cable capacity48 nF/km (at 1 kHz)
Signal runtime5.3 ns/m
Tensile strength≤ 100 N
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Near end crosstalk attenuation (NEXT)71.3 dB (with 1 MHz)
62.3 dB (at 4 МHz)
56.3 dB (at 10 MHz)
53.2 dB (at 16 MHz)
51.8 dB (at 20 МHz)
48.9 dB (at 31.25 МHz)
44.4 dB (at 62.5 МHz)
41.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Resistance to oilin accordance with EN 60811-2-1
Flame resistanceaccording to IEC 60332-1-2
Ambient temperature (operation)-20 °C ... 80 °C (Cable, flexible installation)
-40 °C ... 80 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP67
IP67
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-40 °C ... 70 °C (cable, fixed installation)
-10 °C ... 50 °C (Cable, flexible installation)

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX CONNECTORS EN.pdf 68 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.