Key Commercial Data

Orderkey3247419
Packing unit3 pc
Minimum order quantity3 pc
Catalog pagePage 263 (C-1-2017)
GTIN4055626132969
Weight per Piece (excluding packing)230.730 g
Custom tariff number85359000
Country of originIN (India)

General

Number of levels1
Number of connections2
Potentials1
Nominal cross section95 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition7.54 W
Maximum load current232 A
Nominal current IN232 A
Nominal voltage UN1500 V
Open side panelNo
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width25 mm
Length85.5 mm
Height90 mm
Height NS 35/1597.5 mm
Height NS 3295 mm

Connection data

NoteScrews with hexagonal socket
Connection methodScrew connection
Screw threadM8
Stripping length33 mm
Tightening torque, min15 Nm
Tightening torque max20 Nm
Connection in acc. with standardIEC 60947-7-1
NoteNote: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
Conductor cross section solid min.25 mm²
Conductor cross section solid max.95 mm²
Conductor cross section AWG min.4
Conductor cross section AWG max.3/0
Conductor cross section flexible min.35 mm²
Conductor cross section flexible max.95 mm²
Min. AWG conductor cross section, flexible2
Max. AWG conductor cross section, flexible3/0
Conductor cross section flexible, with ferrule without plastic sleeve min.35 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.95 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.95 mm²
Cross section with insertion bridge, solid max.95 mm²
Cross section with insertion bridge, stranded max.70 mm²
2 conductors with same cross section, solid min.25 mm²
2 conductors with same cross section, solid max.35 mm²
2 conductors with same cross section, stranded min.25 mm²
2 conductors with same cross section, stranded max.35 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.16 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.35 mm²
Connection in acc. with standardIEC/EN 60079-7
Conductor cross section solid min.25 mm²
Conductor cross section solid max.95 mm²
Conductor cross section AWG min.4
Conductor cross section AWG max.3/0
Conductor cross section flexible min.35 mm²
Conductor cross section flexible max.95 mm²

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX TERMINAL BLOCKS EN.pdf 69 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.