PT 4-L/HESILED 60 (5X20) 3002611 PHOENIX CONTACT Fuse modular terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PT 4-L/HESILED 60 (5X20) 3002611 PHOENIX CONTACT Fuse modular terminal block

PT 4-L/HESILED 60 (5X20)

3002611

PHOENIX_CONTACT

50

Fuse modular terminal block

More details


Modular TBs

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey3002611
Packing unit50 pc
Minimum order quantity50 pc
NoteMade to Order (non-returnable)
Catalog pagePage 96 (C-1-2017)
GTIN4055626370248
Weight per Piece (excluding packing)29.270 g
Custom tariff number85369095
Country of originCN (China)

General

NoteThe current is determined by the fuse used, the voltage by the selected LED.
If the fuse is faulty, the downstream circuit will not be disconnected.
Number of levels3
Number of connections4
Nominal cross section4 mm²
Colorblack
Insulating materialPA
Flammability rating according to UL 94V0
Maximum power dissipation for nominal condition1.6 W (the value is multiplied when connecting multiple levels)
FuseG / 5 x 20
Fuse typeGlass / ceramics / ...
Rated surge voltage6 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipationmax. 1.6 W (With single arrangement of the fuse terminal block in the event of overload)
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
max. 4 W (With single arrangement of the fuse terminal block in the event of a short-circuit)
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
LED voltage range30 V AC/DC ... 60 V AC/DC
LED current range0.4 mA ... 0.86 mA
Connection in acc. with standardIEC 60947-7-3
Maximum load current32 A
Nominal current IN28 A
Nominal voltage UN500 V
Connection in acc. with standardIEC 60947-7-3
Maximum load current (upper level)6.3 A (the current is determined by the fuse used)
Nominal current IN(upper level)6.3 A
Nominal voltage UN60 V (the voltage is determined by the light indicator.)
Rated operating voltage250 V
Open side panelYes
Shock protection test specificationDIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protectionguaranteed
Finger protectionguaranteed
Oscillation, broadband noise test resultTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2008-03
Test spectrumService life test category 1, class B, body mounted
Test frequencyf1= 5 Hz to f2= 150 Hz
ASD level0.964 (m/s2)2/Hz
Acceleration0.58 g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
Shock test resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2008-03
Shock formHalf-sine
Acceleration5 g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width6.2 mm
Length118.5 mm
Height NS 35/7,583.9 mm
Height NS 35/1591.4 mm

Ambient conditions

Ambient temperature (operation)-60 °C ... 130 °C

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.4 mm²
Connection methodPush-in connection
Stripping length10 mm ... 12 mm
Internal cylindrical gageA4

Standards and Regulations

Connection in acc. with standardIEC 60947-7-3
IEC 60947-7-3
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX TERMINAL BLOCKS EN.pdf 69 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.