ASI QUINT 100-240/2.4 EFD 2736686 PHOENIX CONTACT Power supply unit View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ASI QUINT 100-240/2.4 EFD 2736686 PHOENIX CONTACT Power supply unit

ASI QUINT 100-240/2.4 EFD

2736686

PHOENIX_CONTACT

Power supply unit

More details


I/O

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2736686
Packing unit1 pc
Catalog pagePage 232 (C-6-2017)
GTIN4017918959678
Weight per Piece (excluding packing)750.000 g
Custom tariff number85044030
Country of originTH (Thailand)

Dimensions

Width55 mm
Height145 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly145 mm
Depth with alternative assembly58 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)95 % (at 25 °C, non-condensing)

Input data

Nominal input voltage range100 V AC ... 240 V AC
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Current consumptionapprox. 1 A (120 V AC)
0.5 A (230 V AC)
Nominal power consumption72 W
Inrush surge current< 15 A (typical)
Mains buffering> 20 ms (120 V AC)
> 80 ms (230 V AC)
Input fuse5 A (slow-blow, internal)
Choice of suitable circuit breakers6 A ... 16 A (Characteristics B, C, D, K)

Output data

Nominal output voltage30.1 V DC ±1.5 %
Output voltage range28 V DC ... 30 V DC
Nominal output current (IN)2.4 A
Connection in parallelNo
Connection in seriesyes
Residual ripple< 30 mVPP
Output power72 W
Typical response time< 0.5 s
Peak switching voltages nominal load< 50 mVPP
Maximum power dissipation in no-load condition3 W
Power loss nominal load max.11 W

General

Net weight0.75 kg
Operating voltage displayLED
Efficiency> 86 % (for 230 V AC and nominal values)
Insulation voltage input/output4 kV AC (type test)
2 kV AC (routine test)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 500000 h
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodPluggable spring-cage connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length9 mm
Screw threadM3

Connection data, output

Connection methodSpring-cage connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM3

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Signal1 kV (Test Level 2 - asymmetrical)
Standards/regulationsEN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Safety of transformersEN 61558-2-17
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
DIN VDE 0100-410
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Safe isolationDIN VDE 0100-410
DIN VDE 0106-1010
Standard – Limitation of mains harmonic currentsEN 61000-3-2
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.