MINI-PS-100-240AC/24DC/C2LPS 2866336 PHOENIX CONTACT Power supply unit View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MINI-PS-100-240AC/24DC/C2LPS 2866336 PHOENIX CONTACT Power supply unit

MINI-PS-100-240AC/24DC/C2LPS

2866336

PHOENIX_CONTACT

Power supply unit

For new installations, use the following items: 2904599 or 2909577
MINI POWER primary switching power supply for rail mounting, input: single-phase, output: 24 V DC/100 W

More details


Power Supplies (PS)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2866336
Packing unit1 pc
Catalog pagePage 235 (C-4-2017)
GTIN4017918975043
Weight per Piece (excluding packing)406.000 g
Custom tariff number85044030
Country of originCN (China)

Dimensions

Width67.5 mm
Height99 mm
Depth107 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)

Input data

Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC
90 V DC ... 350 V DC
AC frequency range45 Hz ... 65 Hz
Current consumption1.3 A (120 V AC)
0.8 A (230 V AC)
1.3 A (90 V DC)
0.4 A (350 V DC)
Nominal power consumption194 VA
Inrush surge current< 15 A (typical)
Mains buffering> 20 ms (120 V AC)
> 100 ms (230 V AC)
Input fuse3.15 A (slow-blow, internal)
Choice of suitable circuit breakers6 A ... 16 A (Characteristics B, C, D, K)

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)22.5 V DC ... 26 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)3.8 A (-25 °C ... 60 °C)
Derating60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Residual ripple< 40 mVPP(20 MHz)
Output power100 W
Typical response time< 0.4 s
Peak switching voltages idling< 100 mVPP(20 MHz)
Maximum power dissipation in no-load condition2.5 W
Power loss nominal load max.12 W

General

Net weight0.4 kg
Operating voltage displayGreen LED
Efficiency> 88 % (for 230 V AC and nominal values)
Insulation voltage input/output3 kV (type test)
3 kV (routine test)
Protection classII (in closed control cabinet)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 815000 h (40 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Connection data, output

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Connection data for signaling

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM3

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageEN 60950-1 (SELV)
EN 60204 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
NEC Class 2 as per UL 1310
Rail applicationsEN 50121-4

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.